俯卧位患者面部压力性损伤预防装置的设计与应用

[Design and application of a device to prevent facial pressure injury in prone patients].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2025-01-01
一句话结论介绍一种获国家实用新型专利的俯卧位面部压力性损伤预防装置,通过自动调节支撑点改变面部受压位置并可视化观察面部情况。

俯卧位通气广泛用于急性呼吸窘迫综合征患者,长时间俯卧位可致面部水肿和压力性损伤风险。临床常用的翻身、保护性敷料和减压垫等措施因气管插管位置不当、敷料自费、口腔鼻腔分泌物清除延迟等因素而效果受限。大连市友谊医院护理部医护人员设计了一种俯卧位面部压力性损伤预防装置,获国家实用新型专利(ZL 2024 2 0340439.8)。该装置由支撑板和电路控制系统组成,通过可调支撑件和伸缩杆定期改变面部受压点,并配备摄像头直接观察面部情况、避免眼鼻受压、及时清除口腔分泌物,结构简单、操作方便、自动化程度高。

要点

  • 装置由支撑板和电路控制系统组成,支撑板上有两个支撑件,支撑件2可通过滑道和螺旋杆调节宽度以适应患者面部大小。
  • 两个支撑件内部有若干伸缩杆,上端为球形支撑,通过电路控制系统调节高度和位置,定期改变面部压力分布。
  • 支撑件2内壁装有摄像头,可通过监视器直接观察患者面部情况,避免眼鼻受压,及时清除口腔分泌物保持面部清洁。
  • 两个支撑件中心为中空槽,便于放置气管导管;电路控制系统含随机模块、时间设定模块、控制模块和驱动模块,参数可按需设置。
  • 装置结构简单、操作方便,能灵活适应患者面部形状,可更换患者面部受压区域,直观查看面部受压情况,自动化程度高、安全性好,有助于降低压力性损伤风险并减轻医护人员工作量。

适用人群与场景

  • 接受俯卧位通气的急性呼吸窘迫综合征患者。

处置流程与药物剂量

  • 装置由支撑板和电路控制系统组成,支撑板上设两个支撑件:支撑件1直接固定于支撑板,支撑件2通过滑道和螺旋杆与支撑板连接,用于支撑患者面部并可根据面部大小调节合适宽度。
  • 两个支撑件内部设若干伸缩杆,上端设计为球形支撑,通过电路控制系统调节伸缩组件的高度和位置,定期改变患者面部压力分布,从而改变面部受压点。
  • 支撑件2内壁装有摄像头,可通过监视器直接观察患者面部情况,避免压迫眼睛和鼻子,并及时清除口腔分泌物保持面部清洁。
  • 两个支撑件中心设中空槽,便于放置气管导管。
  • 电路控制系统包括随机模块、时间设定模块、控制模块和驱动模块,参数可按需设置;达到设定的最短时间时,随机模块和时间设定模块向控制模块发送指令,控制模块接收时间设定模块指令和随机模块随机数后向驱动模块传输信息,驱动模块控制多个伸缩杆调节高度和位置,从而改变患者面部支撑点。

研究设计与关键结果

  • 该装置由大连市友谊医院护理部医护人员设计,获国家实用新型专利(ZL 2024 2 0340439.8)。
  • 装置结构简单、操作方便,能灵活适应患者面部形状,可更换患者面部受压区域,直观查看面部受压情况,自动化程度高、安全性好,有助于降低压力性损伤风险并减轻医护人员工作量。

证据类型、等级与局限

  • 证据类型:装置设计与应用描述(国家实用新型专利,专利号 ZL 2024 2 0340439.8)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 该装置针对俯卧位通气患者面部压力性损伤预防中气管插管位置不当、敷料自费、口腔鼻腔分泌物清除延迟等问题设计,通过自动调节支撑点改变面部受压位置并可视化观察面部情况。
  • 装置中心中空槽便于放置气管导管,摄像头可避免眼鼻受压并及时清除口腔分泌物,有助于降低面部压力性损伤风险并减轻医护人员工作量。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Prone position ventilation (PPV) has been widely used in the treatment strategy of patients with acute respiratory distress syndrome (ARDS). Patients undergoing PPV may develop facial edema and are at risk for pressure injuries due to prolonged prone positioning. In clinical practice, preventive measures such as repositioning, protective dressings, and pressure-relief cushions are commonly used to prevent pressure injuries. However, factors such as improper endotracheal tube placement, self-paid dressings, and delayed clearance of oral and nasal secretions have reduced the effectiveness of preventing facial pressure injuries. To address the above issues, a device for preventing pressure injuries on the faces of patients in the prone position was designed by healthcare workers in the nursing department of Dalian Friendship Hospital, and a National Utility Model Patent of China was obtained (ZL 2024 2 0340439.8). The device consists of a support plate and a circuit control system. The support plate is equipped with two support members. Support member 1 is directly fixed to the support plate, while support member 2 is connected to the support plate via a slide and a spiral rod, serving to support the patient's face and allowing for adjustment of the appropriate width according to the size of the patient's face. Inside the two support members, there are several telescopic rods, with the upper ends designed as spherical supports. The height and position of the telescopic components can be adjusted through a circuit control system, regularly changing the pressure distribution on the patient's face, thereby achieving the purpose of changing the pressure points on the face. The inner wall of support member 2 is equipped with a camera, allowing direct observation of the patient's facial condition through a monitor, avoiding compression of the eyes and nose, and promptly removing secretions from the mouth to keep the face clean, thereby reducing the risk of facial pressure-related injuries. The center of the two support members features a hollow slot, facilitating the placement of a tracheal tube. The circuit control system includes a random module, a time setting module, a control module, and a drive module. Parameters can be set as needed. When the shortest set time is reached, the random module and time setting module send instructions to the control module. Upon receiving the instructions from the time setting module and the random number from the random module, the control module transmits information to the drive module. The drive module, upon receiving the information, controls multiple telescopic rods to adjust their height and position, thereby changing the support points on the patient's face. The device features a simple structure and convenient operation, allowing for flexible adaptation to the patient's facial shape. It can be replaced with the patient's facial pressure area, providing an intuitive view of the patient's facial pressure situation. With automation and high safety, it helps reduce the risk of pressure-related injuries and lightens the workload of medical staff.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Tian Y, Yin Y, Jin X, et al. [Design and application of a device to prevent facial pressure injury in prone patients]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2025. PMID: 41331893. doi:10.3760/cma.j.cn121430-20241209-01011

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。