文献速递心脑血管急症

基于医院的急诊科与独立急诊科快速高敏肌钙蛋白方案结局比较

Comparing Outcomes of a Rapid High-Sensitivity Troponin Protocol Between Hospital-Based and Freestanding Emergency Departments.
PubMed 文献 · Acad Emerg Med · 2025-12-23
一句话结论在独立急诊科实施0/1小时高敏肌钙蛋白加速方案与安全离院率升高相关(95.0% vs 86.0%,aOR 1.48),而基于医院的急诊科无显著变化。

本研究为阶梯楔形整群随机试验的预设二次分析,纳入整合医疗系统内9个急诊科(5个基于医院的急诊科、4个独立急诊科),时间2020年7月至2021年3月,共32,609例成人急诊患者。实施0/1小时高敏肌钙蛋白I加速方案评估急性心肌梗死。主要终点为安全离院(离院后30天内无死亡或急性心肌梗死)。基于医院的急诊科安全离院率标准治疗组53.7% vs 加速方案组50.3%(aOR 1.04,95%CI 0.94-1.15,p=0.50);独立急诊科标准治疗组86.0% vs 加速方案组95.0%(aOR 1.48,95%CI 1.03-2.13,p=0.033)。加速方案与安全离院的关联在独立急诊科强于基于医院的急诊科(Δlog(aOdds) 1.05,95%CI 0.82-1.29,p<0.001)。

要点

  • 独立急诊科实施0/1小时高敏肌钙蛋白I加速方案后安全离院率从86.0%(2102/2443)升至95.0%(3049/3209),aOR 1.48(95%CI 1.03-2.13,p=0.033)。
  • 基于医院的急诊科安全离院率标准治疗组53.7%(5935/11,062) vs 加速方案组50.3%(7991/15,895),aOR 1.04(95%CI 0.94-1.15,p=0.50),无统计学显著差异。
  • 加速方案与安全离院的关联在独立急诊科强于基于医院的急诊科(Δlog(aOdds) 1.05,95%CI 0.82-1.29,p<0.001)。
  • 研究排除ST段抬高型心肌梗死、高敏肌钙蛋白I > 18 ng/L或创伤相关症状的患者。
  • 纳入标准为成人急诊患者且开具心电图和心肌肌钙蛋白检测。

适用人群与场景

  • 成人急诊患者,且开具心电图和心肌肌钙蛋白检测者纳入。
  • 排除ST段抬高型心肌梗死、高敏肌钙蛋白I > 18 ng/L或创伤相关症状的患者。
  • 场景为整合医疗系统内的5个基于医院的急诊科和4个独立急诊科。

诊断标准与关键阈值

  • 采用0/1小时加速方案,使用高敏肌钙蛋白I评估急性心肌梗死。
  • 排除阈值:高敏肌钙蛋白I > 18 ng/L。

研究设计与关键结果

  • 研究类型为阶梯楔形整群随机试验的预设二次分析,纳入9个急诊科(5个基于医院的急诊科、4个独立急诊科),共32,609例患者,其中基于医院的急诊科26,957例,独立急诊科5,652例。
  • 主要终点为安全离院,定义为离院后30天内无死亡或急性心肌梗死。
  • 基于医院的急诊科:标准治疗组安全离院53.7%(5935/11,062) vs 加速方案组50.3%(7991/15,895),aOR 1.04(95%CI 0.94-1.15,p=0.50)。
  • 独立急诊科:标准治疗组安全离院86.0%(2102/2443) vs 加速方案组95.0%(3049/3209),aOR 1.48(95%CI 1.03-2.13,p=0.033)。
  • 加速方案与安全离院的关联在独立急诊科强于基于医院的急诊科(Δlog(aOdds) 1.05,95%CI 0.82-1.29,p<0.001)。

证据类型、等级与局限

  • 证据类型:阶梯楔形整群随机试验的预设二次分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在独立急诊科,实施0/1小时高敏肌钙蛋白I加速方案与安全离院率升高相关(95.0% vs 86.0%,aOR 1.48)。
  • 在基于医院的急诊科,实施该加速方案与安全离院率无显著变化(50.3% vs 53.7%,aOR 1.04,95%CI 0.94-1.15)。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

STUDY OBJECTIVES: Significant variability exists in patient populations and diagnostic capabilities among hospital-based emergency departments (HBEDs) and freestanding emergency departments (FSEDs). While high sensitivity cardiac troponin (hs-cTn) research has focused on HBEDs, its application in FSEDs remains unexplored. This study assesses the comparative, real-world effectiveness of a 0/1-h accelerated protocol (AP) using hs-cTn between HBEDs and FSEDs.

METHODS: We conducted a pre-planned, secondary analysis of a stepped-wedge cluster randomized trial involving nine EDs within an integrated health system, from July 2020 to March 2021, comprised of five HBEDs and four FSEDs. The trial implemented a 0/1-h AP utilizing hs-cTnI to evaluate acute myocardial infarction (AMI). Adult ED patients with an ECG and cardiac troponin ordered were eligible, excluding those with STEMI, hs-cTnI > 18 ng/L, or trauma-related symptoms. The primary outcome was safe ED discharge, defined as discharge without death or AMI within 30 days.

RESULTS: The trial included 32,609 patients, 26,957 in HBEDs and 5652 in FSEDs. Safe discharge from HBED occurred 53.7% (5935/11,062) of the time in the standard care arm and 50.3% (7991/15895) under the AP (aOR 1.04, 95% CI 0.94-1.15, p = 0.50). Safe discharge from a FSED occurred 86.0% (2102/2443) of the time in the standard care arm and increased to 95.0% (3049/3209) under the AP (aOR 1.48, 95% CI 1.03-2.13, p = 0.033). Overall, the observed association between the AP and safe discharge was stronger in FSEDs than in HBEDs ( Δ $$ \Delta $$ log(aOdds) 1.05, 95% CI (0.82, 1.29), p < 0.001).

CONCLUSION: Implementing a 0/1-h AP using hs-cTnI to evaluate for AMI was associated with higher rates of safe discharge in FSEDs compared to HBEDs.

来源:Acad Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Gunaga S, Miller J, Cook B, et al. Comparing Outcomes of a Rapid High-Sensitivity Troponin Protocol Between Hospital-Based and Freestanding Emergency Departments. Acad Emerg Med. 2025. PMID: 41437417. doi:10.1111/acem.70210

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。