文献速递复苏、休克与脓毒症呼吸衰竭与机械通气

院外心脏骤停期间容积控制机械通气中气管插管与声门上气道装置的比较:一项队列研究

Tracheal intubation vs. supraglottic airway devices during mechanical intra-arrest-ventilation with volume-controlled-ventilation in out-of-hospital cardiac arrest: a cohort study.
PubMed 文献 · Resuscitation · 2025-12-04
一句话结论院外心脏骤停患者使用容积控制通气时,气管插管较声门上气道装置输送潮气量更高、与设定潮气量偏差更小、漏气量显著更低。

该队列研究基于德国居特斯洛地区急救服务的真实世界数据,纳入2019年1月至2023年8月期间接受容积控制通气的成人院外心脏骤停病例,比较声门上气道装置与气管插管对通气参数的影响。共27例患者(682分钟)纳入分析,声门上气道组13例(330分钟),气管插管组14例(352分钟)。气管插管组平均漏气量为5.5±7.0%,声门上气道组为42.3±28.4%;气管插管与更小的设定潮气量与实际潮气量差值相关(回归系数-128.3 ml,95%CI [-252.3 ml; -4.3 ml],p=0.0427),并与更低的漏气量相关(回归系数-32.3%,95%CI [-46.1%; -18.4%],p<0.0001)。作者结论认为,在院外心脏骤停容积控制通气中,气管插管与更高的实际输送潮气量、更小的设定潮气量偏差及显著更低的漏气量相关。

要点

  • 在院外心脏骤停容积控制通气中,气管插管组平均漏气量5.5±7.0%,声门上气道组42.3±28.4%,气管插管与更低的漏气量相关(回归系数-32.3%,95%CI [-46.1%; -18.4%],p<0.0001)。
  • 气管插管组平均实际潮气量348.1±215.6 ml,声门上气道组188.2±156.6 ml,气管插管与更高的实际输送潮气量相关。
  • 气管插管与更小的设定潮气量与实际潮气量差值相关(回归系数-128.3 ml,95%CI [-252.3 ml; -4.3 ml],p=0.0427)。
  • 该分析样本量小(共27例,682分钟),结果需在更大样本中进一步验证。

适用人群与场景

  • 成人院外心脏骤停患者,2019年1月至2023年8月期间接受容积控制通气的院外心脏骤停病例,通过声门上气道装置或气管插管进行心脏骤停期间机械通气。
  • 数据来源于德国居特斯洛地区急救服务的真实世界数据,并与德国复苏登记处患者层面信息合并。

研究设计与关键结果

  • 研究类型:队列研究,基于德国居特斯洛地区急救服务真实世界数据,纳入2019年1月至2023年8月接受容积控制通气的成人院外心脏骤停病例,比较声门上气道装置与气管插管。
  • 样本量:共27例患者(682分钟),声门上气道组13例(330分钟),气管插管组14例(352分钟)。
  • 主要终点:设定潮气量与实际潮气量差值,气管插管与更小的差值相关(回归系数-128.3 ml,95%CI [-252.3 ml; -4.3 ml],p=0.0427)。
  • 平均设定潮气量:总体562.8±58.0 ml,气管插管组573.9±62.5 ml,声门上气道组550.9±50.1 ml。
  • 平均实际潮气量:总体270.7±205.5 ml,气管插管组348.1±215.6 ml,声门上气道组188.2±156.6 ml。
  • 平均漏气量:总体23.3±27.4%,气管插管组5.5±7.0%,声门上气道组42.3±28.4%;气管插管与更低的漏气量相关(回归系数-32.3%,95%CI [-46.1%; -18.4%],p<0.0001)。

证据类型、等级与局限

  • 证据类型:队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在院外心脏骤停接受容积控制通气的患者中,使用气管插管较声门上气道装置输送的实际潮气量更高、与设定潮气量偏差更小、漏气量更低。
  • 该结果来自小样本(27例)真实世界数据,作者结论认为气管插管与更好的通气参数相关,未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: This study examines the influence of supraglottic airway (SGA) devices versus tracheal intubation (TI) on key ventilation parameters during intra-arrest-ventilation using volume-controlled-ventilation (VCV) in adult out-of-hospital cardiac arrest (OHCA).

METHODS: This cohort study is based on real-world data obtained from the emergency medical service of the Gütersloh district, Germany. Ventilation data were extracted in March 2024 from emergency ventilators and combined with patient-level information from the German Resuscitation Registry. Adult OHCA cases receiving intra-arrest-ventilation 01/2019-08/2023 with VCV via either SGA or TI were included. Collected parameters included the airway device used, set tidal volume (VTset), measured expiratory tidal volume (VTe), and leakage volume (VLeak). The primary outcome was the difference between VTset-VTe. Patients were grouped according to the airway management strategy used (SGA vs. TI). Potential differences in outcomes between these groups were assessed using linear mixed regression models.

RESULTS: VCV was performed in n = 27 individuals (682 min) using SGA in n = 13 (330 min) vs. TI in n = 14 (352 min). The mean total VTset was 562.8 ± 58.0 ml (TI = 573.9 ± 62.5 ml; SGA = 550.9 ± 50.1 ml). The mean VTe totaled 270.7 ± 205.5 ml (TI = 348.1 ± 215.6 ml; SGA = 188.2 ± 156.6 ml). The mean VLeak was 23.3 ± 27.4 % (TI = 5.5 ± 7.0 %; SGA = 42.3 ± 28.4 %). Compared to SGA, TI was associated with smaller VTset-VTe (regression coefficient: -128.3 ml; 95 %-CI: [-252.3 ml; -4.3 ml]; p = 0.0427) as well as for a lower VLeak (regression coefficient: -32.3 %; 95 %-CI: [-46.1 %; -18.4 %]; p < 0.0001) for TI.

CONCLUSION: In OHCA cases receiving mechanical intra-arrest-ventilation with VCV, TI was associated with higher delivered VTe, less deviation from VTset, and significantly lower VLeak compared to SGA.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Eickelmann C, Beiske AJ, Deicke M, et al. Tracheal intubation vs. supraglottic airway devices during mechanical intra-arrest-ventilation with volume-controlled-ventilation in out-of-hospital cardiac arrest: a cohort study. Resuscitation. 2025. PMID: 41352474. doi:10.1016/j.resuscitation.2025.110918

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。