高氧暴露对脓毒症患者28天病死率及医院获得性感染的影响
该研究基于MIMIC-IV数据库回顾性分析首次ICU入住并接受氧疗超过12小时的脓毒症患者,按FiO2分为<0.60、0.60-0.80和>0.80三组。共纳入1 681例,28天病死率16.48%(277/1 681),医院获得性感染率24.51%(412/1 681)。多因素Logistic回归显示FiO2>0.80是28天死亡的独立危险因素(OR=1.476,95%CI 1.215-1.793,P<0.001),也是医院获得性感染的独立预测因素(OR=1.412,95%CI 1.173-1.698,P<0.001)。Kaplan-Meier分析显示FiO2越高,28天累积生存率越低(log-rank χ²=21.626,P<0.001)。
要点
- 脓毒症患者FiO2>0.80与28天死亡风险独立相关(OR=1.476,95%CI 1.215-1.793,P<0.001)。
- 脓毒症患者FiO2>0.80与医院获得性感染风险独立相关(OR=1.412,95%CI 1.173-1.698,P<0.001)。
- CRRT是28天死亡的独立危险因素(OR=1.391,95%CI 1.000-1.935,P=0.050)。
- 有创机械通气是医院获得性感染的独立预测因素(OR=2.098,95%CI 1.369-3.213,P=0.001)。
- FiO2越高,28天累积生存率越低(log-rank χ²=21.626,P<0.001)。
适用人群与场景
- MIMIC-IV数据库中首次ICU入住、符合Sepsis-3标准且接受氧疗超过12小时的脓毒症患者。
诊断标准与关键阈值
- 脓毒症诊断采用Sepsis-3标准。
- 按FiO2分为三组:<0.60、0.60-0.80、>0.80。
研究设计与关键结果
- 回顾性分析MIMIC-IV数据库28 670例首次ICU入住患者,3 782例符合Sepsis-3标准,其中1 681例接受氧疗超过12小时纳入分析。
- FiO2<0.60组1 378例,FiO2 0.60-0.80组172例,FiO2>0.80组131例。
- 28天病死率16.48%(277/1 681),医院获得性感染率24.51%(412/1 681)。
- 与FiO2<0.60组相比,FiO2 0.60-0.80组和FiO2>0.80组SOFA评分、呼吸频率、心率更高,动脉血氧分压更低,更可能需要有创机械通气、CRRT,肾上腺素使用率更高。
- 多因素Logistic回归:CRRT(OR=1.391,95%CI 1.000-1.935,P=0.050)和FiO2>0.80(OR=1.476,95%CI 1.215-1.793,P<0.001)是28天死亡的独立危险因素。
- 多因素Logistic回归:有创机械通气(OR=2.098,95%CI 1.369-3.213,P=0.001)和FiO2>0.80(OR=1.412,95%CI 1.173-1.698,P<0.001)是医院获得性感染的独立预测因素。
- Kaplan-Meier分析显示不同FiO2组28天累积生存率差异有统计学意义(log-rank χ²=21.626,P<0.001),FiO2越高28天累积生存率越低。
证据类型、等级与局限
- 证据类型:基于MIMIC-IV数据库的回顾性分析。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在脓毒症患者中,FiO2>0.80与28天病死率及医院获得性感染风险升高独立相关,作者结论认为高FiO2(>0.80)与风险增加独立相关。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To analyze the impact of hyperoxia exposure on 28-day mortality and hospital-acquired infections in sepsis patients.
METHODS: Clinical data from the Medical Information Mart for Intensive Care- IV (MIMIC- IV) database were retrospectively analyzed for sepsis patients who received oxygen therapy for more than 12 hours during their first intensive care unit (ICU) admission. Data includes demographics, sequential organ failure assessment (SOFA), acute physiology and chronic health evaluation II (APACHE II), vital signs, laboratory tests, treatment details (such as ventilation settings and medication use), and outcome variables. Patients were divided into three groups based on fraction of inspired oxygen (FiO2) levels: <0.60, 0.60-0.80, and >0.80. The FiO2 was used as the exposure variable, while 28-day mortality and hospital-acquired infections served as the outcome variables. Multivariate Logistic regression analysis was used to investigate the connections between independent variables and outcome variables. Kaplan-Meier survival curve was used to examine the 28-day cumulative survival rate of sepsis patients at various FiO2 levels.
RESULTS: Among 28 670 first-time ICU admissions in the MIMIC- IV database, 3 782 patients met the Sepsis-3 criteria. Among them, 1 681 patients received oxygen therapy for more than 12 hours, with 1 378 patients in the FiO2 < 0.60 group, 172 patients in the FiO2 0.60-0.80 group, and 131 patients in the FiO2 > 0.80 group. The 28-day mortality was 16.48% (277/1 681), and the rate of hospital-acquired infections was 24.51% (412/1 681). Compared with the FiO2 < 0.60 group, patients in both the FiO2 0.60-0.80 and FiO2 > 0.80 groups had higher SOFA scores, respiratory rates, heart rate, but lower arterial partial pressure of oxygen, and also more likely to require invasive mechanical ventilation, continuous renal replacement therapy (CRRT), and had a higher administration rate of epinephrine. Multivariate Logistic regression analysis showed that the CRRT [odds ratio (OR) = 1.391, 95% confidence interval (95%CI) was 1.000-1.935, P = 0.050] and FiO2 > 0.80 (OR = 1.476, 95%CI was 1.215-1.793, P < 0.001) were independent risk factors for 28-day death in sepsis patients. While invasive mechanical ventilation (OR = 2.098, 95%CI was 1.369-3.213, P = 0.001) and FiO2 > 0.80 (OR = 1.412, 95%CI was 1.173-1.698, P < 0.001) were independent predictors of hospital-acquired infection. Kaplan-Meier survival curve analysis showed that there was a statistically significant difference in 28-day cumulative survival rate among sepsis patients in different FiO2 groups (log-rank test, χ 2 = 21.626, P < 0.001). The higher the FiO2, the lower the 28-day cumulative survival rate of patients.
CONCLUSIONS: Among sepsis patients, higher FiO2 (> 0.80) is independently associated with an increased risk of 28-day mortality and hospital-acquired infection.
参考来源
- Bi H, Xiong J, Liu X, et al. [Impact of hyperoxia exposure on 28-day mortality and hospital-acquired infections in sepsis patients]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2025. PMID: 41437583. doi:10.3760/cma.j.cn121430-20250621-00341
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。