不同气道装置对袋阀面罩通气期间心肺复苏中通气的影响:一项前瞻性随机对照尸体研究
该研究为前瞻性随机对照尸体研究,纳入11具Thiel防腐人体尸体,在标准化心肺复苏场景下采用随机顺序使用气管插管或声门上气道装置(喉罩、喉管、i-gel喉罩)进行手动袋阀面罩通气,胸外按压使用Corpuls-CPR装置。主要终点为理想潮气量与呼气潮气量之差(ΔVt)。结果显示气管插管组ΔVt(回归系数RC=-61.07 ml,95%CI -93.58至-28.55,p=0.0003)和漏气量(RC=-20.98%,95%CI -26.63至-15.33,p<0.0001)低于声门上气道组,而呼气潮气量(RC=61.14 ml,95%CI 28.63至93.65,p=0.0003)、平均气道压(RC=0.90 mbar,95%CI 0.59至1.21,p<0.0001)和气道峰压(RC=11.46 mbar,95%CI 8.65至14.26,p<0.0001)高于声门上气道组。声门上气道组内各装置间ΔVt无差异证据。
要点
- 在Thiel防腐尸体心肺复苏模型中,气管插管组ΔVt均值为142.2±125.5 ml,低于声门上气道组的202.0±153.1 ml(RC=-61.07 ml,95%CI -93.58至-28.55,p=0.0003)。
- 气管插管组漏气量均值17.9±15.3%,低于声门上气道组的39.0±23.5%(RC=-20.98%,95%CI -26.63至-15.33,p<0.0001)。
- 气管插管组呼气潮气量均值245.1±91.2 ml,高于声门上气道组的183.8±122.1 ml(RC=61.14 ml,95%CI 28.63至93.65,p=0.0003)。
- 气管插管组气道峰压均值47.7±14.9 mbar、平均压4.0±1.5 mbar,均高于声门上气道组的39.0±10.0 mbar和3.1±1.0 mbar(Ppeak RC=11.46 mbar,95%CI 8.65至14.26;Pmean RC=0.90 mbar,95%CI 0.59至1.21)。
- 声门上气道组内各装置(喉罩、喉管、i-gel喉罩)之间ΔVt无差异证据。
适用人群与场景
- Thiel防腐人体尸体,共11具,死亡时平均年龄84±3.7岁,男性7具(63.6%)。
- 标准化心肺复苏场景,胸外按压使用Corpuls-CPR装置,通气为手动袋阀面罩通气。
处置流程与药物剂量
- 按随机顺序使用不同气道装置进行通气:气管插管或声门上气道装置(喉罩、喉管、i-gel喉罩),通气方式为手动袋阀面罩通气。
研究设计与关键结果
- 研究类型:前瞻性随机对照尸体研究;样本量11具尸体。
- 主要终点ΔVt:气管插管组均值142.2±125.5 ml,声门上气道组均值202.0±153.1 ml,气管插管组更低(RC=-61.07 ml,95%CI -93.58至-28.55,p=0.0003)。
- 漏气量:气管插管组17.9±15.3%,声门上气道组39.0±23.5%,气管插管组更低(RC=-20.98%,95%CI -26.63至-15.33,p<0.0001)。
- 呼气潮气量:气管插管组245.1±91.2 ml,声门上气道组183.8±122.1 ml,气管插管组更高(RC=61.14 ml,95%CI 28.63至93.65,p=0.0003)。
- 平均气道压:气管插管组4.0±1.5 mbar,声门上气道组3.1±1.0 mbar,气管插管组更高(RC=0.90 mbar,95%CI 0.59至1.21,p<0.0001)。
- 气道峰压:气管插管组47.7±14.9 mbar,声门上气道组39.0±10.0 mbar,气管插管组更高(RC=11.46 mbar,95%CI 8.65至14.26,p<0.0001)。
- 声门上气道组内各装置间ΔVt无差异证据。
证据类型、等级与局限
- 证据类型:前瞻性随机对照尸体研究。
- 试验注册:clinicaltrials.gov,注册号NCT06306898,注册日期2024年3月5日。
- 局限:原文未报告局限性。
对床旁实践的改变
- 该尸体研究显示,在手动袋阀面罩通气期间,气管插管较声门上气道装置漏气量更低、呼气潮气量更高,但气道峰压和平均压也更高;声门上气道组内各装置间ΔVt无差异证据。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Out-of-hospital cardiac arrest remains a major challenge due to its high incidence and low survival rates. In recent decades, research has focused on the performance of chest compressions and improvements in early defibrillation, while the optimal ventilation strategy remains unclear. Despite the lack of monitoring systems, manual bag-valve-device ventilation is still common. Given the potential impact of both the applied volumes and the ventilation pressures on hemodynamics and resuscitation efforts, the present study investigated the effects of various airway devices on the target parameters of ventilation therapy during manual intra-arrest ventilation.
METHODS: Thiel-embalmed human cadavers were included in a standardized resuscitation scenario. Ventilation was performed in a randomized order using various airway devices (tracheal tube (ET), supraglottic airway devices (SGA): laryngeal mask airway, laryngeal tube, i-gel® laryngeal mask) and manual bag-valve-device ventilation. Chest compressions were performed via Corpuls-CPR. Ideal (Vtideal), expiratory (Vte) and inspiratory (Vti) tidal volumes; leakage volume (Vleak); and peak (Ppeak) and mean (Pmean) pressures were recorded. The primary efficacy endpoint was the difference between Vtideal and Vte (∆Vt).
RESULTS: Eleven cadavers were included (mean age at the time of death: 84 ± 3.7 years, male = 7 [63.6%]). During ventilation with ET, the following mean values were measured: ΔVt, 142.2 ± 125.5 ml; Vte, 245.1 ± 91.2 ml; Vleak, 17.9 ± 15.3%; Pmean, 4.0 ± 1.5 mbar; and Ppeak, 47.7 ± 14.9 mbar. During ventilation with SGA, however, the mean values were ΔVt, 202.0 ± 153.1 ml; Vte, 183.8 ± 122.1 ml; Vleak, 39.0 ± 23.5%; Pmean, 3.1 ± 1.0 mbar; and Ppeak, 39.0 ± 10.0 mbar. Comparison of the two groups revealed lower ΔVt values (regression coefficient [RC] = -61.07 ml, 95% confidence interval [95% CI] = [-93.58;-28.55], p = 0.0003) and Vleak values (RC = -20.98%, 95% CI = [-26.63;-15.33], p<0.0001), but higher Vte values (RC = 61.14 ml, 95% CI = [28.63;93.65], p = 0.0003), Pmean values (RC = 0.90 mbar, 95% CI = [0.59;1.21], p<0.0001), and Ppeak values (RC = 11.46 mbar, 95% CI = [8.65;14.26], p<0.0001) in the ET group. There was no evidence for differences in ΔVt among the cadavers in the SGA group.
CONCLUSION: The ∆Vt was lower in the ET group than the SGA group, whereas there was no evidence for differences in ∆Vt among the devices in the SGA group.
TRIAL REGISTRATION: clinicaltrials.gov; Unique identifier: NCT06306898, Registration date: 5 March 2024.
参考来源
- Lohmann J, Brand-Saberi B, Ullrich M, et al. Influence of different airway devices on intra-arrest ventilation during bag-valve-device ventilation - a prospective randomized controlled cadaver study. Crit Care. 2025. PMID: 41345669. doi:10.1186/s13054-025-05713-z
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。