指南与共识呼吸衰竭与机械通气重症综合管理与镇静镇痛

急性呼吸功能不全有创通气与体外膜氧合临床指南:机械通气模式选择与参数设置的更新循证推荐

Clinical Guideline for Treating Acute Respiratory Insufficiency with Invasive Ventilation and Extracorporeal Membrane Oxygenation: Updated Evidence-Based Recommendations for Choosing Modes and Setting Parameters of Mechanical Ventilation.
指南 / 共识 · Respiration · 2025-12-11
一句话结论2025年德奥瑞士指南更新:中重度ARDS不优先早期神经肌肉阻滞,建议早期辅助通气;肺保护性通气VT约6 mL/kg、平台压≤30 cmH2O、驱动压≤14 cmH2O。

本指南基于系统GRADE流程制定,以MAGICapp数字形式发布,面向德国、奥地利和瑞士医疗环境,更新了成人急性呼吸功能不全有创机械通气模式选择与关键参数设置的推荐。中重度ARDS患者不再优先早期神经肌肉阻滞,临床合适时建议早期允许自主呼吸的辅助策略。压力控制、分钟通气支持且吸呼气均允许自主呼吸的模式可用于低氧性呼吸衰竭(证据确定性极低、试验间异质性明显)。首次对自适应通气模式给出推荐:ASV/INTELLiVENT-ASV等部分自适应模式及神经调节通气辅助可个体化考虑,流量和容量比例辅助通气(如PAV/PAV+)不推荐。参数推荐强调肺保护性通气:VT约6 mL/kg预测体重(范围4-8 mL/kg)、平台压≤30 cmH2O、驱动压≤14 cmH2O;中重度ARDS用较高PEEP并根据床旁生理个体化;氧合目标SaO2/SpO2 92-96%或PaO2 70-90 mm Hg。

要点

  • 中重度ARDS有创通气患者不再优先早期神经肌肉阻滞,临床合适时建议(弱推荐)早期允许自主呼吸的辅助策略。
  • 低氧性呼吸衰竭可考虑压力控制、分钟通气支持且吸气与呼气均允许自主呼吸的模式,证据确定性极低且试验间异质性明显。
  • 自适应模式中ASV/INTELLiVENT-ASV及神经调节通气辅助可个体化考虑;流量和容量比例辅助通气(如PAV/PAV+)不推荐(证据确定性低、频繁不耐受)。
  • 肺保护性通气参数:VT约6 mL/kg预测体重(范围4-8 mL/kg)、平台压≤30 cmH2O、驱动压≤14 cmH2O。
  • 中重度ARDS应使用较高PEEP并按床旁生理个体化;氧合目标SaO2/SpO2 92-96%或PaO2 70-90 mm Hg,兼顾低氧与高氧风险。

适用人群与场景

  • 成人急性呼吸功能不全接受有创机械通气的患者,适用于德国、奥地利和瑞士医疗环境。

处置流程与药物剂量

  • 中重度ARDS有创通气患者:不再优先早期神经肌肉阻滞,临床合适时建议(弱推荐)早期允许自主呼吸的辅助策略。
  • 低氧性呼吸衰竭:可考虑压力控制、分钟通气支持且吸气和呼气均允许自主呼吸的模式(证据确定性极低,试验间异质性明显)。
  • 自适应通气模式:ASV/INTELLiVENT-ASV等部分自适应模式及神经调节通气辅助可个体化考虑;流量和容量比例辅助通气(如PAV/PAV+)不推荐(证据确定性低、频繁不耐受)。
  • 参数设置:VT约6 mL/kg预测体重(范围4-8 mL/kg),平台压≤30 cmH2O,驱动压≤14 cmH2O。
  • 中重度ARDS应使用较高PEEP,并根据床旁生理个体化。
  • 氧合目标:SaO2/SpO2 92-96%或PaO2 70-90 mm Hg,以平衡低氧和高氧风险。
  • 推荐持续心肺监测,并使用二氧化碳波形图确认气管插管位置和评估趋势。

研究设计与关键结果

  • 本指南基于系统GRADE流程制定,以MAGICapp数字形式发布,面向德国、奥地利和瑞士医疗环境,保留了实用的通气模式分类并更新了多项临床推荐。
  • 中重度ARDS有创通气患者不再优先早期神经肌肉阻滞,临床合适时建议早期允许自主呼吸的辅助策略。
  • 压力控制、分钟通气支持且吸呼气均允许自主呼吸的模式可用于低氧性呼吸衰竭,但证据确定性极低且试验间异质性明显。
  • 首次对自适应通气模式给出推荐:ASV/INTELLiVENT-ASV等部分自适应模式及神经调节通气辅助可个体化考虑,流量和容量比例辅助通气(如PAV/PAV+)不推荐(证据确定性低、频繁不耐受)。
  • 参数推荐:VT约6 mL/kg预测体重(范围4-8 mL/kg)、平台压≤30 cmH2O、驱动压≤14 cmH2O;中重度ARDS用较高PEEP并床旁个体化;氧合目标SaO2/SpO2 92-96%或PaO2 70-90 mm Hg。
  • 推荐持续心肺监测及二氧化碳波形图用于确认插管位置和趋势评估。

证据类型、等级与局限

  • 证据类型:指南(基于系统GRADE流程制定的循证推荐)。
  • 部分推荐证据确定性极低(如允许自主呼吸的压力控制、分钟通气支持模式),试验间存在明显异质性;流量和容量比例辅助通气不推荐基于低确定性证据和频繁不耐受。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 中重度ARDS有创通气时不再优先早期神经肌肉阻滞,临床合适时作者建议(弱推荐)早期允许自主呼吸的辅助策略。
  • 低氧性呼吸衰竭可考虑压力控制、分钟通气支持且吸呼气均允许自主呼吸的模式,但需注意证据确定性极低且试验间异质性明显。
  • 自适应模式中仅ASV/INTELLiVENT-ASV等部分模式及神经调节通气辅助可个体化考虑;PAV/PAV+不推荐(证据确定性低、频繁不耐受)。
  • 所有有创通气患者按VT约6 mL/kg预测体重(范围4-8 mL/kg)、平台压≤30 cmH2O、驱动压≤14 cmH2O设置参数,中重度ARDS用较高PEEP并床旁个体化。
  • 氧合目标为SaO2/SpO2 92-96%或PaO2 70-90 mm Hg,需持续心肺监测并用二氧化碳波形图确认插管位置和趋势。

指南或共识出处

  • 2025年德国、奥地利和瑞士急性呼吸功能不全有创通气与体外膜氧合临床指南(MAGICapp数字发布)。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

<p>Invasive mechanical ventilation remains a cornerstone in the treatment of critically ill patients suffering from acute respiratory failure, providing life-sustaining gas exchange while necessitating careful selection of modes and settings to maximize benefit and minimize harm. This guideline-derived review synthesizes updated, critically appraised, and evidence-based recommendations on choosing ventilatory modes and setting key parameters in adults with acute respiratory insufficiency. Building on a systematic GRADE process and presented digitally in the MAGICapp, the 2025 guideline for the German, Austrian, and Swiss healthcare context retains a pragmatic taxonomy of ventilatory modes and updates several clinical recommendations. In invasively ventilated patients with moderate-to-severe ARDS, early neuromuscular blockade is no longer favored; instead, early assisted strategies that allow spontaneous breathing are suggested when clinically appropriate. Pressure-controlled, minute ventilation-supporting modes that enable spontaneous breathing during both inspiration and expiration may be considered in hypoxemic respiratory failure, acknowledging very low certainty of evidence and notable heterogeneity across trials. For the first time, our guideline issues recommendations on adaptive ventilation modes. Some adaptive modes (e.g., ASV/INTELLiVENT-ASV) and neurally adjusted ventilatory assist may be considered on a case-by-case basis, whereas flow- and volume-proportional assist ventilation (e.g., PAV/PAV+) is not recommended given low-certainty evidence and frequent intolerance. Parameter recommendations emphasize lung-protective ventilation with VT ≈ 6 mL/kg predicted body weight (range 4-8 mL/kg), a plateau pressure ≤30 cm H2O, and a driving pressure ≤14 cm H2O. Positive end-expiratory pressure should be higher in moderate/severe ARDS and individualized using bedside physiology, while oxygen targets of SaO2/SpO2 92-96% or PaO2 70-90 mm Hg balance hypoxemia and hyperoxia risks. Continuous cardiorespiratory monitoring and capnography for tube placement confirmation and trend assessment are endorsed. Collectively, these recommendations aim to support safe, effective, and implementable ventilatory care while transparently conveying where certainty of evidence remains limited. </p>.

来源:Respiration,查看原文。版权归原作者所有。

参考来源

  1. Hohmann F, Fichtner F, Becher T, et al. Clinical Guideline for Treating Acute Respiratory Insufficiency with Invasive Ventilation and Extracorporeal Membrane Oxygenation: Updated Evidence-Based Recommendations for Choosing Modes and Setting Parameters of Mechanical Ventilation. Respiration. 2025. PMID: 41379760. doi:10.1159/000549732

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。