文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

呼吸相关皮层激活与机械通气脱机的关联:一项生理学研究

Association between respiratory-related cortical activation and weaning from mechanical ventilation: a physiological study.
PubMed 文献 · Crit Care · 2025-11-03
一句话结论在通过脱机筛查的机械通气患者中,T管自主呼吸试验开始15分钟内吸气前电位较机械通气时升高超过0.43 µV与SBT失败相关(敏感性100%、特异性87%)。

这项单中心生理学前瞻性研究纳入62例符合脱机标准的机械通气患者,在机械通气下和T管SBT开始15分钟内用脑电图测量吸气前电位(PIP)振幅。17例(27%)SBT失败;失败组机械通气下PIP振幅低于通过组,但SBT开始时PIP振幅高于通过组,且从机械通气到SBT的PIP变化在失败组升高、通过组降低。PIP升高超过0.43 µV与SBT失败相关,敏感性100%、特异性87%。作者认为呼吸相关皮层激活增加与SBT失败相关,是可用于更好表型分类脱机候选患者的生理学标志物。

要点

  • 62例符合脱机标准的机械通气患者中17例(27%)SBT失败,失败组SBT开始时PIP振幅2.1 µV(IQR 1.7-2.9)高于通过组1.2 µV(IQR 0.5-2.0),p<0.005。
  • 机械通气下PIP振幅失败组0.6 µV(IQR 0-1.3)低于通过组1.9 µV(IQR 1.2-2.9),p<0.0001。
  • 从机械通气到SBT的PIP振幅变化:失败组+1.7 µV(IQR 1.2-2.1)vs 通过组-0.5 µV(IQR -1.8-0.1),p<0.0001。
  • PIP升高超过0.43 µV与SBT失败相关,敏感性100%、特异性87%。
  • 作者认为呼吸相关皮层激活增加与SBT失败相关,是可用于更好表型分类脱机候选患者的生理学标志物。

适用人群与场景

  • 符合脱机标准的机械通气患者,单中心生理学前瞻性研究人群。

诊断标准与关键阈值

  • SBT采用T管进行,持续1小时;SBT失败定义为未通过1小时T管SBT。
  • PIP振幅在机械通气下及SBT开始15分钟内用脑电图测量。

研究设计与关键结果

  • 单中心生理学前瞻性研究,纳入62例符合脱机标准的机械通气患者,17例(27%)SBT失败。
  • 机械通气下PIP振幅:失败组0.6 µV(IQR 0-1.3)vs 通过组1.9 µV(IQR 1.2-2.9),p<0.0001。
  • SBT开始时PIP振幅:失败组2.1 µV(IQR 1.7-2.9)vs 通过组1.2 µV(IQR 0.5-2.0),p<0.005。
  • 从机械通气到SBT的PIP振幅变化:失败组+1.7 µV(IQR 1.2-2.1)vs 通过组-0.5 µV(IQR -1.8-0.1),p<0.0001。
  • PIP升高超过0.43 µV与SBT失败相关,敏感性100%、特异性87%。

证据类型、等级与局限

  • 证据类型:单中心生理学前瞻性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为呼吸相关皮层激活增加与SBT失败相关,是可用于更好表型分类脱机候选患者的生理学标志物。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: In mechanically ventilated patients, extubation is decided after passing a spontaneous breathing trial (SBT). Supplementary motor area, which can be non-invasively assessed by measuring amplitude of pre-inspiratory potentials (PIPs), is recruited in case of increased respiratory effort. Weaning failure may be accompanied by increased respiratory effort. We hypothesized that early increased PIP amplitude from the start of SBT may be associated with SBT failure.

PATIENTS AND METHODS: We performed a single-center physiological prospective study in mechanically ventilated patients meeting weaning criteria. PIP amplitude was measured using electroencephalography under mechanical ventilation and then during the first 15-min of the SBT performed using a T-piece. We compared respiratory-related cortical activation between patients who passed a 1-h SBT and those who failed.

RESULTS: Among the 62 patients included, 17 (27%) failed the SBT. Whereas patients who failed the SBT had a lower median amplitude of PIPs under mechanical ventilation than those who passed the SBT (0.6 µV [IQR, 0-1.3] vs. 1.9 [1.2-2.9], p < 0.0001), they had a higher amplitude of PIPs at the beginning of the SBT (2.1 µV [IQR, 1.7-2.9] vs. 1.2 [0.5-2.0], p < 0.005). PIP amplitude between mechanical ventilation and SBT significantly increased in case of SBT failure whereas it decreased in case of SBT success (+ 1.7 µV [1.2-2.1] vs. -0.5 [-1.8-0.1], p < 0.0001). An increase of PIP above 0.43 µV was associated with SBT failure with sensitivity of 100% and specificity of 87%.

CONCLUSION: The demonstration of an association between increased respiratory-related cortical activation and failure of the weaning trial is a physiological marker of interest for better phenotyping of patients ready for weaning.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Rault CCS, Thille AW, Héraud Q, et al. Association between respiratory-related cortical activation and weaning from mechanical ventilation: a physiological study. Crit Care. 2025. PMID: 41184870. doi:10.1186/s13054-025-05706-y

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。