文献速递复苏、休克与脓毒症心脑血管急症

胸外按压期间动脉多普勒超声血流波形用于检测动脉线搏动性

Arterial Doppler Ultrasound Blood Flow Waveforms During Chest Compressions to Detect Arterial Line Pulsatility.
PubMed 文献 · Ann Emerg Med · 2025-10-18
一句话结论胸外按压期间动脉多普勒超声血流波形对后续脉搏检查时动脉线搏动性有良好诊断准确性,按压中搏动性波形者收缩压更高。

该回顾性诊断准确性研究纳入44例急诊科成人心脏骤停患者(均置有股动脉动脉线),分析123次胸外按压期间股动脉多普勒超声血流波形与后续脉搏检查时动脉线搏动性的关系。波形分为双向血流、极少血流、前向主导血流和按压中搏动性四类。总体准确率88.9%(95%CI 81.3–93.7),按压中搏动性或前向主导血流检测动脉线搏动性的敏感性97.7%(95%CI 87.7–99.6),双向血流或极少血流判定无搏动性的特异性81.5%(95%CI 69.3–89.6)。按压中搏动性波形者脉搏检查时估计最小二乘均值收缩压较前向主导血流者高50.9 mmHg(95%CI 25.6–76.1)。

要点

  • 胸外按压期间股动脉多普勒超声出现按压中搏动性或前向主导血流波形时,后续脉搏检查动脉线搏动性的敏感性为97.7%(95%CI 87.7–99.6)。
  • 双向血流或极少血流波形判定后续脉搏检查无动脉线搏动性的特异性为81.5%(95%CI 69.3–89.6)。
  • 四类波形总体诊断准确率为88.9%(95%CI 81.3–93.7)。
  • 按压中搏动性波形者脉搏检查时估计最小二乘均值收缩压较前向主导血流波形者高50.9 mmHg(95%CI 25.6–76.1 mmHg)。
  • 该研究为回顾性诊断准确性研究,样本为44例急诊科成人心脏骤停患者、123次波形-脉搏检查配对。

适用人群与场景

  • 成人急诊科心脏骤停患者,均置有股动脉动脉线。

诊断标准与关键阈值

  • 多普勒超声血流波形分为四类:双向血流、极少血流、前向主导血流、按压中搏动性。
  • 脉搏检查时记录动脉线波形有无及最高收缩压。

研究设计与关键结果

  • 研究类型为回顾性诊断准确性研究,样本为前瞻性收集的便利样本,共44例患者、123次多普勒超声波形及后续脉搏检查。
  • 四类波形总体准确率88.9%(95%CI 81.3–93.7)。
  • 按压中搏动性或前向主导血流检测动脉线搏动性的敏感性97.7%(95%CI 87.7–99.6)。
  • 双向血流或极少血流判定无动脉线搏动性的特异性81.5%(95%CI 69.3–89.6)。
  • 按压中搏动性波形者脉搏检查时估计最小二乘均值收缩压较前向主导血流波形者高50.9 mmHg(95%CI 25.6–76.1 mmHg)。

证据类型、等级与局限

  • 证据类型:回顾性诊断准确性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为胸外按压期间动脉多普勒超声血流波形对后续脉搏检查时动脉线搏动性具有良好的诊断试验特征。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

STUDY OBJECTIVE: Doppler ultrasound blood flow waveforms during active chest compressions are unique and may allow identification of return of spontaneous circulation. We assessed diagnostic accuracy of 4 identified Doppler ultrasound blood flow waveforms-(1) bidirectional blood flow, (2) minimal blood flow, (3) anterograde dominant blood flow, and (4) pulsatility through compressions-during chest compressions to detect arterial line (a-line) pulsatility during a subsequent pulse check. Secondarily, we assessed if pulsatility through compressions was associated with higher systolic blood pressure (SBP) at pulse check than anterograde dominant blood flow.

METHODS: We conducted a retrospective, diagnostic accuracy study on a prospectively collected convenience sample of adult, emergency department cardiac arrest patients. All patients had a femoral a-line. Prior to a pulse check, Doppler ultrasound clips of the femoral artery were saved and reviewed. During a pulse check, the presence or absence of an arterial line waveform and the highest SBP were recorded. Accuracy, sensitivity, and specificity of the blood flow waveforms were calculated using generalized estimating equation models.

RESULTS: Forty-four patients with 123 Doppler ultrasound waveforms and subsequent pulse checks were analyzed. Accuracy of the Doppler ultrasound waveforms was 88.9% (95% confidence interval [CI] 81.3 to 93.7), sensitivity of pulsatility through compressions or anterograde dominant blood flow to detect a-line pulsatility was 97.7% (95% CI 87.7 to 99.6), and specificity of bidirectional blood flow or minimal blood flow for the absence of a-line pulsatility was 81.5% (95% CI 69.3 to 89.6). Estimated least-squares mean SBP was higher (50.9 mmHg [95% CI 25.6 to 76.1 mmHg]) for pulsatility through compressions than anterograde dominant blood flow waveforms.

CONCLUSION: Arterial Doppler ultrasound waveforms during chest compressions had good diagnostic test characteristics for detecting arterial line pulsatility at subsequent pulse check.

来源:Ann Emerg Med,查看原文。版权归原作者所有。