文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

楚格急救服务救援环境中的气道管理分析:一项回顾性真实世界评估

Airway management analysis in the rescue environment of the emergency service Zug: a retrospective real-world evaluation.
PubMed 文献 · Scand J Trauma Resusc Emerg Med · 2025-10-22
一句话结论在瑞士楚格急救服务的270例成人气管插管中,总体首次插管成功率为92.6%,使用探条辅助者首次成功率为100%(49/49),高于使用管芯者的91.0%(201/221)。

本研究回顾了2021年1月1日至2024年12月31日楚格急救服务数据库中全部成人(≥18岁)气管插管尝试,共270例,平均年龄67.9±16.4岁,64.8%为男性,55.6%的插管发生在心肺复苏期间。总体首次插管成功率为92.6%(250/270);使用探条者首次成功率为100%(49/49),使用管芯者为91.0%(201/221),两者差异P=0.03。按器械划分,直接喉镜为94.3%(33/35),标准几何视频喉镜为94.0%(173/184),D-BLADE视频喉镜为86.3%(44/51);在预判困难气道患者中,使用D-BLADE视频喉镜者首次插管成功率为89.7%(P<0.001)。与急诊医师相比,重症监护急救员的首次插管成功几率更高(OR 3.61,95%CI 1.14至11.45)。

要点

  • 总体首次插管成功率为92.6%(250/270),其中55.6%的插管发生在心肺复苏期间。
  • 使用探条辅助喉镜者首次成功率为100%(49/49),高于使用管芯者的91.0%(201/221),P=0.03。
  • 在预判困难气道的患者中,使用D-BLADE视频喉镜者首次插管成功率为89.7%(P<0.001)。
  • 重症监护急救员与急诊医师相比,首次插管成功的OR为3.61(95%CI 1.14至11.45)。
  • 按器械划分,直接喉镜首次成功率为94.3%(33/35),标准几何视频喉镜为94.0%(173/184),D-BLADE视频喉镜为86.3%(44/51)。

适用人群与场景

  • 纳入2021年1月1日至2024年12月31日楚格急救服务数据库中记录的全部成人(≥18岁)气管插管尝试,共270例,平均年龄67.9±16.4岁,64.8%为男性。

研究设计与关键结果

  • 回顾性真实世界评估,纳入270例成人气管插管尝试,其中55.6%发生在心肺复苏期间。
  • 总体首次插管成功率为92.6%(250/270)。
  • 使用探条者首次插管成功率为100%(49/49),使用管芯者为91.0%(201/221),P=0.03。
  • 按器械划分首次插管成功率:直接喉镜94.3%(33/35),标准几何视频喉镜94.0%(173/184),D-BLADE视频喉镜86.3%(44/51)。
  • 在预判困难气道的患者中,使用D-BLADE视频喉镜者首次插管成功率为89.7%(P<0.001)。
  • 与急诊医师相比,重症监护急救员的首次插管成功几率更高(OR 3.61,95%CI 1.14至11.45)。

证据类型、等级与局限

  • 研究类型:回顾性真实世界评估。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,探条辅助喉镜与更高的首次插管成功率显著相关。
  • 作者认为,在预判存在困难气道时,超角度D-BLADE视频喉镜显示出更高的首次插管成功几率。
  • 作者认为,重症监护急救员达到的首次插管成功率与急诊医师相当。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Airway management is critical in prehospital care. This study quantified first pass success (FPS) for endotracheal intubation (ETI) in a Swiss emergency medical service (EMS) and identified factors associated with success.

METHODS: All adult (≥ 18 years) ETI attempts documented in the EMS database between 1 January 2021 and 31 December 2024 were reviewed. Devices [direct laryngoscopy, standard-geometry videolaryngoscope (VL), hyperangulated VL], adjuncts [bougie, stylet], operators [critical-care paramedic (CCP), emergency physician (EP)] and setting were analyzed. The primary outcome was FPS; predictors were evaluated with univariate and multivariable logistic regression.

RESULTS: ETI was attempted in 270 patients (mean age 67.9 ± 16.4 year; 64.8% male); 55.6% intubations occurred during cardiopulmonary resuscitation. Overall FPS was 92.6% (250/270). Bougie use achieved 100% (49/49) FPS versus 91.0% (201/221) with a stylet (p = 0.03). Device-specific FPS was 94.3% (33/35, direct laryngoscopy), 94.0% (173/184, standard-geometry VL) and 86.3% (44/51, D-BLADE VL). FPS was significantly associated with D-BLADE VL use in patients with an anticipated difficult intubation (89,7% FPS, p < 0.001). CCP showed higher odds for FPS for CCP compared to EP (OR 3.61, 95% CI 1.14 to 11.45).

CONCLUSIONS: Bougie-assisted laryngoscopy was significantly associated with higher first pass success rates. When a difficult airway was anticipated, the hyperangulated D-BLADE videolaryngoscope showed higher odds for first pass success. Critical-care paramedics achieved first pass success rates comparable to those of emergency physicians.

TRIAL REGISTRATION: Clinical Trials.gov: NCT06653166 (19 October 2024).

来源:Scand J Trauma Resusc Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Brinkmann F, Cajoeri G, Sahli SD, et al. Airway management analysis in the rescue environment of the emergency service Zug: a retrospective real-world evaluation. Scand J Trauma Resusc Emerg Med. 2025. PMID: 41126289. doi:10.1186/s13049-025-01489-x

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。