院前急救中的动脉内血压监测:范围综述
该范围综述检索了PubMed、EMBASE、MEDLINE、Cochrane Central和CINAHL截至2025年4月15日的文献,纳入24项涉及成人(≥18岁)院前动脉内血压监测的研究。最常见适应证为心肺复苏和复苏后治疗,92%的置管由医师完成,桡动脉最常用,置管成功率82%,严重并发症非常罕见(肱动脉置管风险最高)。动脉内与非侵入性血压测量一致性低,53%的患者根据动脉内血压监测采取了行动。作者结论认为置管成功率和并发症风险可接受,但纳入研究多为观察性,需随机对照试验分析明确人群中以患者为中心的结局。
要点
- 院前动脉内血压监测最常见适应证为心肺复苏和复苏后治疗,92%的置管由医师完成。
- 桡动脉是最常用置管部位,置管成功率82%,严重并发症非常罕见,肱动脉置管并发症风险最高。
- 动脉内与非侵入性血压测量一致性低,53%的患者根据动脉内血压监测采取了行动。
- 置管在不同时间点进行,对院前时间的影响不一。
- 纳入研究多为观察性研究,作者认为需随机对照试验分析明确人群中以患者为中心的结局。
适用人群与场景
- 成人(≥18岁)在院前急救场景中接受动脉内血压监测的患者。
- 最常见适应证为心肺复苏和复苏后治疗。
处置流程与药物剂量
- 动脉置管由医师在92%的病例中完成。
- 桡动脉是最常用的置管部位。
- 置管在不同时间点进行,对院前时间的影响不一。
研究设计与关键结果
- 范围综述共筛选1456项研究,最终纳入24项研究。
- 最常见适应证为心肺复苏和复苏后治疗;92%的置管由医师完成;桡动脉最常用;置管成功率82%;严重并发症非常罕见,肱动脉置管并发症风险最高。
- 动脉内与非侵入性血压测量一致性低;53%的患者根据动脉内血压监测采取了行动;置管在不同时间点进行,对院前时间的影响不一。
证据类型、等级与局限
- 证据类型:范围综述,纳入研究多为观察性研究。
- 局限:纳入研究多为观察性研究,需随机对照试验分析明确人群中以患者为中心的结局。
对床旁实践的改变
- 院前急救中可对成人患者(尤其是心肺复苏和复苏后治疗场景)考虑动脉内血压监测,医师置管成功率为82%,严重并发症非常罕见,但肱动脉置管并发症风险最高。
- 动脉内与非侵入性血压测量一致性低,53%的患者根据动脉内血压监测采取了行动,提示该监测可能影响院前决策。
- 作者认为需随机对照试验分析明确人群中以患者为中心的结局。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Blood pressure is a key vital sign in prehospital emergency care and essential for assessing the hemodynamic status and guiding treatment. In the prehospital setting, blood pressure is usually measured intermittently with non-invasive cuff-techniques. However, intraarterial blood pressure monitoring with an arterial catheter offers continuous and more accurate measurements. This scoping review aimed to synthesize and analyze the current literature on intraarterial blood pressure monitoring in prehospital emergency care.
METHODS: PubMed, EMBASE, MEDLINE, Cochrane Central, and CINAHL were searched on April 15, 2025, following PRISMA-ScR guidelines and Joanna Briggs Institute methodology. Studies involving adults (≥ 18 years) having prehospital intraarterial blood pressure monitoring were included.
RESULTS: 1456 studies were screened and 24 studies finally included. The most frequent indications for intraarterial blood pressure monitoring were cardiopulmonary resuscitation and post resuscitation care. Arterial cannulation was performed by physicians in 92% of the cases. The radial artery was the most frequently used cannulation site. Arterial cannulation was successful in 82% of the patients. Major complications were very rare, with brachial artery cannulation bearing the highest risk for complications. Low agreement between intraarterial and non-invasive blood pressure measurements was reported. Actions based on intraarterial blood pressure monitoring were performed in 53% of the patients. Arterial cannulation was performed during different timepoints and had varying effects on prehospital time.
CONCLUSIONS: Intraarterial blood pressure monitoring has been studied across a wide range of indications in prehospital emergency care with an acceptable cannulation success rate and low risk of complications. However, the included studies were mostly observational, necessitating randomized controlled trials analyzing patient-centered outcomes in defined populations.
参考来源
- Eichlseder M, Labenbacher S, Schreiber N, et al. Intraarterial blood pressure monitoring in prehospital emergency care: a scoping review. Scand J Trauma Resusc Emerg Med. 2025. PMID: 41088326. doi:10.1186/s13049-025-01473-5
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。