指南与共识呼吸衰竭与机械通气重症综合管理与镇静镇痛

成人重症患者胸部电阻抗成像评估肺通气与灌注的国际循证专家德尔菲共识推荐

Recommendations for lung ventilation and perfusion assessment with chest electrical impedance tomography in critically ill adult patients: an international evidence-based and expert Delphi consensus study.
指南 / 共识 · EClinicalMedicine · 2025-10-17
一句话结论国际专家共识基于87条推荐(15条强共识、70条共识、2条未达成共识)支持在成人重症患者中应用胸部电阻抗成像(EIT)检测动态肺部异常和不均一性。

该国际循证专家共识针对成人重症患者胸部电阻抗成像(EIT)评估肺通气与灌注,通过系统检索1990年1月1日至2024年3月22日文献(MEDLINE、EMBASE、Web of Science、Cochrane Library),排除动物研究,采用牛津循证医学中心证据等级方法评价证据质量和推荐强度,并经2024年6月3日和9月13日两轮在线调查的德尔菲流程由12个国家专家制定推荐。最终14个问题产生11,159篇摘要,242篇文献用于制定87条推荐,涵盖数据采集与分析、临床应用和未来展望。第一轮20名、第二轮18名扩展组专家完成调查,最终15条强共识、70条共识、2条未达成共识;强共识集中于数据采集、分析、培训与解读、体位对肺通气的影响、肺灌注及通气/灌注匹配,未达成共识者集中于区域通气延迟比和心跳相关EIT信号灌注评估。推荐证据质量多为中等(A级3/87、B级47/87、C-D级37/87)。作者认为证据和专家共识支持EIT用于检测动态肺部异常和不均一性,可能显著影响临床管理和最终诊断,未来制定EIT指南亟需高质量证据。

要点

  • 87条推荐中15条为强共识(>95%专家同意)、70条为共识(75-95%同意)、2条未达成共识(<75%同意)。
  • 强共识推荐集中于EIT数据采集、分析、培训与解读、体位对肺通气影响的评估、肺灌注及通气/灌注匹配。
  • 未达成共识的推荐集中于区域通气延迟比和心跳相关EIT信号的灌注评估。
  • 推荐证据质量多为中等:A级3/87、B级47/87、C-D级37/87。
  • 作者认为证据和专家共识支持EIT检测动态肺部异常和不均一性,可能显著影响临床管理和最终诊断。

适用人群与场景

  • 成人重症患者,用于胸部EIT评估肺通气与灌注。
  • 纳入文献限于成人人群的胸部EIT肺通气与灌注应用研究,排除动物研究。

诊断标准与关键阈值

  • 强共识定义为>95%专家同意,共识定义为75-95%专家同意,无共识定义为<75%专家同意。
  • 证据质量与推荐强度采用牛津循证医学中心证据等级方法评价。

研究设计与关键结果

  • 研究类型为国际循证专家德尔菲共识研究,检索MEDLINE、EMBASE、Web of Science和Cochrane Library数据库1990年1月1日至2024年3月22日文献,排除动物研究。
  • 最终14个问题产生11,159篇摘要,242篇相关文献用于制定87条推荐,涵盖数据采集与分析、临床应用和未来展望。
  • 第一轮20名、第二轮18名扩展组专家完成调查,最终15条强共识、70条共识、2条未达成共识。
  • 强共识推荐集中于数据采集、分析、培训与解读、体位对肺通气影响的评估、肺灌注及通气/灌注匹配。
  • 未达成共识的推荐集中于区域通气延迟比和心跳相关EIT信号的灌注评估。
  • 推荐证据质量:A级3/87、B级47/87、C-D级37/87。

证据类型、等级与局限

  • 证据类型为国际循证专家德尔菲共识,采用牛津循证医学中心证据等级方法评价证据质量和推荐强度。
  • 推荐证据质量多为中等:A级3/87、B级47/87、C-D级37/87。
  • 局限:作者指出未来制定EIT指南亟需高质量证据。

对床旁实践的改变

  • 作者认为证据和专家共识支持EIT用于检测动态肺部异常和不均一性,可能显著影响临床管理和最终诊断。

指南或共识出处

  • Recommendations for lung ventilation and perfusion assessment with chest electrical impedance tomography in critically ill adult patients: an international evidence-based and expert Delphi consensus study(EClinicalMedicine)。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Electrical impedance tomography (EIT) is a non-invasive, radiation-free imaging technique that allows for monitoring of lung ventilation and perfusion at the bedside. However, there is a lack of evidence-based and international expert consensus statement of EIT clinical applications in adult critically ill patients. The purpose of this study was to provide evidence-based and expert consensus recommendations for lung ventilation and perfusion assessment with chest EIT in adult critically ill patients.

METHODS: A English literature search was conducted of MEDLINE, EMBASE, Web of Science and Cochrane Library databases between January 1, 1990, and J March 22, 2024. Eligible literature included systematic reviews, meta-analyses, cohort/clinical trials, case reports and review articles that focused on chest EIT application for lung ventilation and perfusion in adult population. The animal studies were excluded. An international global panel of intensivists, physicians, biomedical engineers with expertise in the field of EIT clinical applications, guideline methodologists and biostatisticians, was convened. The Oxford Centre of Evidence Based Medicine's Levels of Evidence method was used to rate the quality of evidence and the strength of recommendations. Subsequently, with a Delphi process (two online surveys at June 3 and September 13, 2024), a group of expanded global experts from 12 different countries developed recommendations. We defined a strong consensus as agreement of >95% experts, consensus as agreement of 75-95% experts and no consensus as agreement<75%. The study is registered with PREPARE, PREPARE-2024CN166.

FINDINGS: The final 14 questions generated a total of 11,159 abstracts, of which 242 publications were identified relevant to develop 87 recommendations. The 87 statements focused on data acquisition and analysis, clinical application, and future perspectives were developed and modified. Twenty experts in the expanded group completed the survey in the first round, and eighteen experts in the expanded group completed the survey in the second round. At the end of the Delphi process, 15 recommendations were identified as strong consensus, 70 recommendations as consensus, and two recommendations did not reach consensus. The statements with strong consensus were focused on data acquisition, analysis, training and interpretation, assessment of posture effect on lung ventilation, lung perfusion and ventilation/perfusion match, and the statements without agreement were focused on regional ventilation delay ratio, perfusion assessment with heart-beat related EIT signal. Recommendations were mostly based on moderate quality of evidence (3/87 was A grade, 47/87 was B grade, 37/87 was C-D grade of recommendation).

INTERPRETATION: Our study provides evidence-based recommendations with high consensus for using chest EIT for lung ventilation and perfusion in adult critically ill patients. Evidence and expert consensus supports the application of EIT in the detection of dynamic pulmonary abnormalities and inhomogeneities, which may significantly influence clinical management and final diagnosis. High quality evidence is urgently needed for the development of EIT guidelines in the future.

FUNDING: National High-Level Hospital Clinical Research Funding, National Key Research and Development Program, National Natural Science Foundation of China, Peking Union Medical College Hospital Talent Cultivation Program Category C.

来源:EClinicalMedicine,查看原文。版权归原作者所有。

参考来源

  1. He H, Zhao Z, Becher T, et al. Recommendations for lung ventilation and perfusion assessment with chest electrical impedance tomography in critically ill adult patients: an international evidence-based and expert Delphi consensus study. EClinicalMedicine. 2025. PMID: 41158153. doi:10.1016/j.eclinm.2025.103575

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。