文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

心脏胸骨切开术后膈肌功能障碍的影像与临床特征

[Imaging and clinical features of diaphragm dysfunction after cardiac sternotomy].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2025-01-01
一句话结论心脏胸骨切开术后第7天28.4%患者仍存在膈肌功能障碍,以左侧为主,与术前房颤、肺动脉高压相关,并增加肺炎发生率和延长机械通气及ICU住院时间。

该前瞻性队列研究纳入67例择期心脏胸骨切开术患者,术前、拔管后24小时内及术后第7天行膈肌超声测量膈肌移动度(DE)、膈肌厚度(DT)及膈肌增厚分数(DTF),术前术后行胸部CT测量膈肌抬高分数(DEF)。术后第7天19例(28.4%)存在膈肌功能障碍(DE<1 cm)。膈肌功能障碍组术后第7天DE及DTF较非膈肌功能障碍组显著降低,以左侧为著,DT无显著差异。该组术前房颤及肺动脉高压比例更高,术中高流量氧疗及肺炎发生率更高,机械通气时间及ICU住院时间更长。

要点

  • 术后第7天28.4%(19/67)患者仍存在膈肌功能障碍(DE<1 cm),拔管后24小时内24例出现膈肌功能障碍。
  • 膈肌功能障碍组术后第7天DE 1.06±0.77 cm vs 非膈肌功能障碍组1.59±0.63 cm,DTF 19.3%(14.8%, 21.1%)vs 21.3%(18.3%, 26.1%),均P<0.05。
  • 膈肌功能障碍组左侧DE在拔管后24小时内及术后第7天均显著低于右侧(0.93±0.72 vs 1.45±0.70 cm;1.06±0.77 vs 1.70±0.92 cm,均P<0.05)。
  • 术前房颤(36.8% vs 10.4%)及肺动脉高压(15.8% vs 2.1%)在膈肌功能障碍组比例更高(均P<0.05)。
  • 膈肌功能障碍组术中高流量氧疗(52.6% vs 25.0%)及肺炎(73.7% vs 45.8%)发生率更高,机械通气时间47.0(38.0, 73.0)小时 vs 24.5(20.0, 48.0)小时,ICU住院时间69.0(65.0, 117.5)小时 vs 60.0(42.3, 90.6)小时,均P<0.05。

适用人群与场景

  • 2023年6月至9月在天津医科大学总医院心血管外科接受择期心脏胸骨切开术的患者。
  • 纳入标准为择期心脏胸骨切开术患者,排除标准原文未报告。

诊断标准与关键阈值

  • 膈肌功能障碍定义为术后第7天膈肌移动度(DE)<1 cm。
  • 膈肌超声测量DE、DT并计算DTF;胸部CT测量膈肌顶点至胸廓顶点距离并计算DEF。

研究设计与关键结果

  • 前瞻性队列研究,纳入67例择期心脏胸骨切开术患者,术后第7天19例(28.4%)存在膈肌功能障碍,48例(71.6%)无膈肌功能障碍。
  • 膈肌功能障碍组术后第7天DE 1.06±0.77 cm vs 非膈肌功能障碍组1.59±0.63 cm,DTF 19.3%(14.8%, 21.1%)vs 21.3%(18.3%, 26.1%),均P<0.05;DT各时间点两组无显著差异。
  • 膈肌功能障碍组左侧DE在拔管后24小时内及术后第7天均显著低于右侧(0.93±0.72 vs 1.45±0.70 cm;1.06±0.77 vs 1.70±0.92 cm,均P<0.05),双侧DT及DTF无显著差异。
  • 胸部CT显示术后膈肌抬高发生率为61.2%(41/67),未抬高38.8%(26/67),两组间及组内两侧DEF均无统计学显著差异。
  • 膈肌功能障碍组术前房颤36.8%(7/19)vs 10.4%(5/48),肺动脉高压15.8%(3/19)vs 2.1%(1/48),均P<0.05。
  • 膈肌功能障碍组术中高流量氧疗52.6%(10/19)vs 25.0%(12/48),肺炎73.7%(14/19)vs 45.8%(22/48),均P<0.05。
  • 膈肌功能障碍组机械通气时间47.0(38.0, 73.0)小时 vs 24.5(20.0, 48.0)小时,ICU住院时间69.0(65.0, 117.5)小时 vs 60.0(42.3, 90.6)小时,均P<0.05。

证据类型、等级与局限

  • 证据类型:前瞻性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 对心脏胸骨切开术后患者,膈肌超声可识别术后第7天仍存在膈肌功能障碍者,该组左侧DE下降更显著。
  • 术前房颤及肺动脉高压患者术后发生膈肌功能障碍的比例更高,该组术中高流量氧疗及肺炎发生率更高、机械通气时间和ICU住院时间更长。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To analyze the imaging and clinical features of diaphragm dysfunction in patients who underwent selective cardiac sternotomy with diaphragm ultrasound and chest CT.

METHODS: A prospective cohort study was conducted. The patients undergoing selective cardiac sternotomy in the cardiac and vascular surgery department of Tianjin Medical University General Hospital from June to September 2023 were enrolled. Bedside ultrasound was performed on the day before surgery, within 24 hours of extubation, and on the 7th day after surgery to measure diaphragm excursion (DE) and diaphragm thickness (DT), and to calculate the diaphragm thickening fraction (DTF). The distance from the diaphragm's apex to the thorax's apex in the chest CT scout view was measured before and after the operation, and the diaphragm elevating fraction (DEF) was calculated. Patients were divided into two groups based on whether diaphragm dysfunction (DE < 1 cm) occurred on the 7th day after surgery. The change patterns of imaging indicators were analyzed in both groups. The clinical data of both groups before, during, and after surgery were compared.

RESULTS: In total, 67 patients who underwent cardiac sternotomy were enrolled. Among them, 24 patients developed diaphragm dysfunction within 24 hours after extubation; on the 7th day after surgery, 19 patients (28.4%) still exhibited diaphragm dysfunction, while 48 patients (71.6%) did not. Ultrasonic examination of the diaphragm revealed that, compared with the non-diaphragm dysfunction group, patients in the diaphragm dysfunction group exhibited varying degrees of decrease in DE and DTF before and after surgery, with a more significant decrease on the left side, and the differences were statistically significant on the 7th day after surgery [DE (cm): 1.06±0.77 vs. 1.59±0.63, DTF: 19.3% (14.8%, 21.1%) vs. 21.3% (18.3%, 26.1%), both P < 0.05]. There was no statistically significant difference in DT between the two groups at each time point. Changes in bilateral DE and DTF revealed that the non-diaphragm dysfunction group experienced early transient postoperative weakening of diaphragm function, followed by rapid recovery to the preoperative level on the 7th day after surgery, unlike the diaphragm dysfunction group. There were no significant differences between bilateral DE in the two groups on the day before surgery, and the left DE was significantly lower than the right DE within 24 hours after extubation and on the 7th day after surgery in the diaphragm dysfunction group (cm: 0.93±0.72 vs. 1.45±0.70 within 24 hours after extubation, 1.06±0.77 vs. 1.70±0.92 on the 7th day after surgery, both P < 0.05) but no significant difference was found in bilateral DT or DTF. The chest CT scan showed that, the incidence of postoperative diaphragm elevation was 61.2% (41/67), and 38.8% (26/67) did not, while no statistically significant difference in DEF was found between the two groups, nor within each group on both sides. Analysis of the clinical data showed a higher proportion of atrial fibrillation and pulmonary hypertension before surgery [atrial fibrillation: 36.8% (7/19) vs. 10.4% (5/48), pulmonary hypertension: 15.8% (3/19) vs. 2.1% (1/48), both P < 0.05], a higher incidence of high-flow oxygenation and pneumonia during surgery [high-flow oxygenation: 52.6% (10/19) vs. 25.0% (12/48), pneumonia: 73.7% (14/19) vs. 45.8% (22/48), both P < 0.05], and a longer duration of mechanical ventilation and length of intensive care unit (ICU) stay [duration of mechanical ventilation (hours): 47.0 (38.0, 73.0) vs. 24.5 (20.0, 48.0), length of ICU stay (hours): 69.0 (65.0, 117.5) vs. 60.0 (42.3, 90.6), both P < 0.05] in the diaphragm dysfunction group as compared with those in the non-diaphragm dysfunction group.

CONCLUSIONS: There was a high incidence of diaphragm dysfunction after cardiac sternotomy, which reflected the early transient postoperative weakening of diaphragm function, followed by rapid recovery to the preoperative level in most patients, predominantly on the left side. Diaphragm dysfunction, which was associated with atrial fibrillation and pulmonary hypertension significantly increased the incidence of postoperative pneumonia and prolonged the duration of mechanical ventilation and length of ICU stay.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Zhu X, Wu D, Zhang H, et al. [Imaging and clinical features of diaphragm dysfunction after cardiac sternotomy]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2025. PMID: 41017180. doi:10.3760/cma.j.cn121430-20250116-00062

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。