文献速递心脑血管急症重症综合管理与镇静镇痛

床旁超声主动脉流出道尺寸与主动脉夹层诊断的关系

Relationship of aortic outflow tract size on point-of-care ultrasound to aortic dissection diagnosis.
PubMed 文献 · Am J Emerg Med · 2025-08-27
一句话结论单中心回顾性研究显示,主动脉夹层患者床旁超声主动脉流出道(AOFT)直径较无夹层者增大,但AOFT测量单独不应被用于排除主动脉夹层。

该单中心回顾性横断面研究纳入2013年11月1日至2024年11月30日急诊就诊的223例主动脉夹层患者(59.2%为Stanford A型,40.8%为B型,总死亡率21.1%)及100例无夹层对照。在141例(63.2%)接受床旁超声的患者中,A型夹层平均AOFT为4.65 cm(中位数4.65 cm;IQR 4.05-5.18 cm),B型夹层为3.94 cm(中位数3.85 cm;IQR 3.55-4.36 cm),均显著大于无夹层对照的3.29 cm(中位数3.32 cm;IQR 3.02-3.60 cm)(p<0.001)。先做CTA与先做POCUS、以及有无POCUS的患者之间,至CTA时间无统计学显著差异(p=0.54和p=0.67)。作者认为AOFT扩张与主动脉夹层强相关,但AOFT测量单独不应被用于排除主动脉夹层。

要点

  • 在141例接受床旁超声的主动脉夹层患者中,A型夹层平均AOFT为4.65 cm(中位数4.65 cm;IQR 4.05-5.18 cm),B型为3.94 cm(中位数3.85 cm;IQR 3.55-4.36 cm),差异有统计学意义(p<0.001)。
  • 无夹层对照的平均AOFT为3.29 cm(中位数3.32 cm;IQR 3.02-3.60 cm),夹层患者AOFT显著大于对照。
  • 先做CTA与先做POCUS的患者至CTA时间无统计学显著差异(p=0.54),有无POCUS的患者至CTA时间也无统计学显著差异(p=0.67)。
  • 作者结论明确:AOFT测量单独不应被用于排除主动脉夹层。
  • 该研究为单中心回顾性横断面研究,作者提出未来需通过前瞻性多中心验证AOFT测量以提高POCUS对主动脉夹层的特异性。

适用人群与场景

  • 年龄≥18岁、基于ICD-10编码诊断为主动脉夹层的急诊患者,以及100例接受心脏床旁超声的随机无夹层对照患者。
  • 排除标准包括:病历无法找到、主动脉溃疡、腹主动脉瘤、无夹层的胸主动脉扩张、既往修复的主动脉夹层无急性夹层、慢性夹层、重复就诊或编码错误的就诊。

研究设计与关键结果

  • 研究类型为单中心回顾性横断面研究,纳入223例主动脉夹层患者和100例无夹层对照,夹层患者中132例(59.2%)为A型、91例(40.8%)为B型,总死亡率21.1%(47例死亡)。
  • 141例(63.2%)患者接受了床旁超声,其中A型夹层98例,平均AOFT 4.65 cm(中位数4.65 cm;IQR 4.05-5.18 cm);B型夹层43例,平均AOFT 3.94 cm(中位数3.85 cm;IQR 3.55-4.36 cm);A型与B型差异有统计学意义(p<0.001)。
  • 无夹层对照的平均AOFT为3.29 cm(中位数3.32 cm;IQR 3.02-3.60 cm),夹层患者AOFT显著大于对照。
  • 在未转运的已知夹层患者中,先做CTA与先做POCUS的患者至CTA时间无统计学显著差异(p=0.54);有无POCUS的患者至CTA时间也无统计学显著差异(p=0.67)。

证据类型、等级与局限

  • 证据类型为单中心回顾性横断面研究。
  • 作者指出AOFT测量单独不应被用于排除主动脉夹层。
  • 作者提出未来研究应聚焦于通过前瞻性多中心验证AOFT测量以提高POCUS对主动脉夹层的特异性。

对床旁实践的改变

  • 作者结论认为,AOFT测量单独不应被用于排除主动脉夹层。
  • 作者认为AOFT扩张与主动脉夹层强相关,但该结论来自单中心横断面研究。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Aortic dissection is an uncommon diagnosis with a high mortality rate. Point-of-care ultrasound (POCUS) can serve as an adjunct to computed tomography angiography (CTA) to diagnose aortic dissection. We aimed to determine the association of the aortic outflow tract (AOFT) diameter on POCUS with Stanford type A and type B dissections, along with determining the time to POCUS and CTA.

METHODS: This was a retrospective cross-sectional study of all patients presenting to an Emergency Department (ED) with over 110,000 annual visits between November 1, 2013, and November 30, 2024, found to have an aortic dissection. All ED patients ≥18 years old with an aortic dissection were included based on ICD-10 code. We also separately included 100 random patients for a normal non-dissection cohort who had received a cardiac POCUS. Patients were excluded based on chart review if their chart was unable to be located, if they had an aortic ulceration, abdominal aortic aneurysm, or thoracic aortic dilation without dissection; if they had a previously repaired aortic dissection without acute dissection; if they had a chronic dissection; duplicate visits; or an incorrectly coded visit. Chart review and POCUS image review was conducted by trained study investigators for patient demographics, diagnosis, outcomes, and AOFT diameter measured outside-to-inside. The primary study outcome was the size of AOFT on ED POCUS, while the secondary outcomes were time to CTA in patients who were not transferred with a known dissection comparing both patients who had CTA first versus POCUS first, and comparing those with and without POCUS.

RESULTS: A total of 223 aortic dissection patients plus 100 non-dissection patients were included. There were 132 (59.2 %) type A dissections and 91 (40.8 %) type B dissections, with an overall mortality rate of 21.1 % (47 deaths). Of the 141 patients (63.2 %) with a POCUS performed, there were 98 type A dissections with an average AOFT size of 4.65 cm (median 4.65 cm; IQR 4.05-5.18 cm) and 43 type B dissections with an average AOFT size of 3.94 cm (median 3.85 cm; IQR 3.55-4.36 cm), which was a statistically significant difference (p < 0.001), and significantly greater than the normal cohort AOFT of 3.29 cm (median 3.32 cm; IQR 3.02-3.60 cm). There was no statistically significant difference in time to CTA in both patients who had CTA first versus POCUS first (p = 0.54), and comparing those with and without POCUS (p = 0.67).

CONCLUSION: The average AOFT size was 4.65 cm (median 4.65 cm; IQR 4.05-5.18 cm) for type A dissections and 3.94 cm (median 3.85 cm; IQR 3.55-4.36 cm) for type B dissections, compared to 3.29 cm (median 3.32 cm; IQR 3.02-3.60 cm) in a non-dissection cohort, showing a strong association between aortic dissection and a dilated AOFT in a single center cross-sectional study. AOFT measurement alone should not be used to rule out aortic dissection. Future research should focus on improving specificity of POCUS for aortic dissection through a prospective multicentered validation of AOFT measurements.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Boivin Z, Agaraj I, Danta M, et al. Relationship of aortic outflow tract size on point-of-care ultrasound to aortic dissection diagnosis. Am J Emerg Med. 2025. PMID: 40886677. doi:10.1016/j.ajem.2025.08.059

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。