文献速递复苏、休克与脓毒症

自动体外除颤器电击后手动除颤的能量水平选择

Energy levels in manual defibrillation after prior AED shock.
PubMed 文献 · Resuscitation · 2025-09-23
一句话结论在院外心脏骤停患者中,从自动体外除颤器过渡到手动除颤器时,急救人员对递增能量方案的依从率仅20.3%,且依从性与临床结局无显著关联。

该研究基于荷兰ARREST登记库,分析827例成人院外心脏骤停且可电击心律、至少接受一次自动体外除颤器和一次手动除颤器电击的病例。主要终点为对递增能量方案(首次手动电击360 J而非默认200 J)的依从性,结果为20.3%(95%CI 17.7%-23.2%)。首次手动电击终止可电击心律的比例在200 J组为79.1%(521/659),在360 J组为82.7%(139/168),差异无统计学意义(p=0.33)。30天总生存率为38.4%,多变量分析未显示依从性与临床结局存在显著关联。

要点

  • 在827例从自动体外除颤器过渡到手动除颤器的院外心脏骤停患者中,对递增能量方案的依从率仅为20.3%(95%CI 17.7%-23.2%)。
  • 首次手动除颤器电击终止可电击心律的比例:200 J组为79.1%(521/659),360 J组为82.7%(139/168),两组差异无统计学意义(p=0.33)。
  • 总体30天生存率为38.4%,多变量分析显示对递增能量方案的依从性与临床结局无显著关联。
  • 未发现任何基线特征与依从性提高显著相关。

适用人群与场景

  • 成人院外心脏骤停患者,具有可电击心律,且至少接受一次自动体外除颤器电击和一次手动除颤器电击。

研究设计与关键结果

  • 研究类型为基于荷兰ARREST登记库的分析,共纳入827例成人院外心脏骤停且可电击心律、至少接受一次自动体外除颤器和一次手动除颤器电击的病例。
  • 主要终点为对递增能量方案的依从性,依从率为20.3%(95%CI 17.7%-23.2%)。
  • 首次手动除颤器电击终止可电击心律的比例:200 J组为79.1%(521/659),360 J组为82.7%(139/168),p=0.33。
  • 总体30天生存率为38.4%。
  • 多变量分析显示,对递增能量方案的依从性与临床结局无显著关联。
  • 未发现任何基线特征与依从性提高显著相关。

证据类型、等级与局限

  • 证据类型:基于登记库的观察性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 原文结论指出,急救人员在从自动体外除颤器过渡到手动除颤器时对递增能量方案的依从性有限,且数据未提供依从性与临床结局相关的证据。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM: European guidelines suggest an escalating defibrillation energy protocol for cases of out-of-hospital cardiac arrest (OHCA) with a shockable rhythm. Our regional manual defibrillators are by default set to deliver 200 J for the initial shock and 360 J for subsequent shocks. In case of a prior AED shock, Emergency Medical Services (EMS) personnel need to deliberately adjust the energy level to 360 J before delivering the first shock with their manual defibrillator to adhere to the escalating energy protocol. We investigated adherence to this escalating energy protocol by EMS and the association with clinical outcomes.

METHODS: Data were collected from the ARREST-registry in (the) Netherlands. We analysed OHCA cases in adults with shockable rhythms who had received at least one shock from an AED and from a manual defibrillator. The primary outcome was the adherence to the escalating energy protocol. Secondary outcomes were the relationships of adherence with various clinical outcomes.

RESULTS: In 827 cases, adherence to the escalating energy protocol was 20.3 % (95 % CI 17.7 %-23.2 %). No baseline characteristics were significantly associated with increased adherence. Shockable rhythms were terminated by the first manual defibrillator shock in 521/659 (79.1 %) cases with 200 J and 139/168 (82.7 %) cases with 360 J (p = 0.33). Overall 30-day survival rate was 38.4 %. Adherence to protocol was not significantly associated with differences in clinical outcomes after multivariable analyses.

CONCLUSION: Adherence to escalating energy protocol by EMS during transition from defibrillation with AED to manual defibrillator is limited. Our data did not provide evidence for a relationship between adherence and clinical outcomes.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Dammers F, Verkaik BJ, Stieglis R, et al. Energy levels in manual defibrillation after prior AED shock. Resuscitation. 2025. PMID: 40997994. doi:10.1016/j.resuscitation.2025.110841

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。