一句话结论低能量双相波除颤在各使用场景下均高效,且与除颤阻抗无关;旁观者与受训第一响应者的除颤成功率更高、再发室颤率更低。

本研究分析美国与欧洲2358例成人院外心脏骤停(OHCA)病例,按AED使用人群分为旁观者(HS1)、受训第一响应者(FRx)和急救医疗服务(EMS,FR3)三组,所有AED均释放低能量、阻抗补偿的双相波。在560例患者的953次除颤中,总体除颤成功率分别为95.0%、94.0%和86.6%(p<0.001),首次除颤成功率分别为96.9%、94.5%和89.0%(p=0.007),再发室颤率组间差异显著(p=0.016)。除颤阻抗与除颤成功或再发室颤无关;较高的振幅谱面积(AMSA)与再发室颤减少显著相关(HR 0.95,95%CI 0.92-0.98),但未能完全解释组间差异。

要点

  • 在560例患者953次除颤中,总体除颤成功率旁观者组95.0%、第一响应者组94.0%、EMS组86.6%,组间差异显著(p<0.001)。
  • 首次除颤成功率旁观者组96.9%、第一响应者组94.5%、EMS组89.0%(p=0.007),旁观者与受训第一响应者均高于EMS。
  • 再发室颤率三组间差异显著(p=0.016);首次除颤成功后2分钟内再发室颤者中,再发室颤中位时间旁观者组38.7秒、第一响应者组31.0秒、EMS组27.4秒。
  • 除颤阻抗与除颤成功率或再发室颤均无关;较高的AMSA与再发室颤减少显著相关(HR 0.95,95%CI 0.92-0.98)。
  • 所有AED均释放低能量、阻抗补偿的双相波,在此条件下各使用场景除颤均高度有效。

适用人群与场景

  • 美国与欧洲的成人院外心脏骤停(OHCA)病例,共2358例,使用HS1、FRx或FR3三种AED模型之一。
  • 按AED使用人群分为三组:旁观者(HS1)、受训第一响应者(FRx)、EMS(FR3)。

研究设计与关键结果

  • 研究类型为对2358例成人OHCA病例心电数据的分析,其中560例患者共953次除颤纳入分析;三种AED均释放低能量、阻抗补偿的双相波。
  • 总体除颤成功率:旁观者组95.0%、第一响应者组94.0%、EMS组86.6%(p<0.001)。
  • 首次除颤成功率:旁观者组96.9%、第一响应者组94.5%、EMS组89.0%(p=0.007)。
  • 再发室颤率三组间差异显著(p=0.016);首次除颤成功后2分钟内再发室颤者中,再发室颤中位时间旁观者组38.7秒、第一响应者组31.0秒、EMS组27.4秒。
  • 除颤阻抗与除颤成功率或再发室颤均无关;较高的AMSA与再发室颤减少显著相关(HR 0.95,95%CI 0.92-0.98),但未能完全解释组间差异。

证据类型、等级与局限

  • 证据类型:基于美国与欧洲成人OHCA病例心电数据的分析研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 使用低能量、阻抗补偿双相波AED时,旁观者与受训第一响应者的除颤成功率高于EMS,再发室颤率更低;EMS响应时间通常更长。
  • 除颤阻抗不影响除颤成功或再发室颤,床旁选择AED时无需以阻抗为考量。
  • 较高的AMSA与再发室颤减少相关,但AMSA不能完全解释不同使用人群间的结局差异。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Automated external defibrillator (AED) outcomes in out-of-hospital cardiac arrest (OHCA) are known to be impacted by diverse usage scenarios including time to shock. This study compared shock efficacy and refibrillation rate across AED user groups and analyzed influencing factors.

METHODS: We examined ECG data from 2358 adult OHCA cases in the US and Europe treated with three AED models (HS1, FRx, and FR3), all delivering low-energy, impedance-compensating biphasic shocks. Cases were grouped by AED used: lay-responder (HS1), trained first-responder (FRx), and EMS (FR3). Shock success and refibrillation were compared, and regression analyses assessed their associations with amplitude spectrum area (AMSA) and shock impedance.

RESULTS: Among 953 shocks in 560 patients, overall shock efficacy differed: 95.0 % (lay-responder), 94.0 % (first-responder), and 86.6 % (EMS) (p < 0.001). First shock efficacy was 96.9 % (lay-responder), 94.5 % (first-responder), and 89.0 % (EMS) (p = 0.007). Refibrillation rates varied significantly among groups (p = 0.016). Among patients who refibrillated within two minutes after a successful first shock, the median time to refibrillation was 38.7 (lay-responder), 31.0 (first-responder), and 27.4 (EMS) seconds. Shock impedance was not associated with shock efficacy or refibrillation. Higher AMSA was significantly associated with reduced refibrillation (hazard ratio, 0.95; 95 % CI, 0.92-0.98) but did not fully explain group differences.

CONCLUSIONS: Across use scenarios, low-energy biphasic shocks were highly effective, independent of shock impedance. Lay and minimally trained responders achieved better shock efficacy and lower refibrillation rates than first responders or EMS, which typically have longer response times. While AMSA correlated with refibrillation, additional factors may also influence AED outcomes.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Chen S, Liu C, Gehman S, et al. Variations of shock efficacy and refibrillation in different AED user groups. Resuscitation. 2025. PMID: 40997995. doi:10.1016/j.resuscitation.2025.110843

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。