全血与总输血量比值较高与需大量输血的创伤患者生存结局
该研究为基于美国国家创伤数据库2020年数据的回顾性队列研究,纳入≥16岁、到院4小时内接受全血输注的创伤患者902例。以全血与总输血量比值0.5为最佳截断值分组,高全血组143例、低全血组759例。经逆概率治疗加权调整的logistic回归显示,高全血组24小时死亡OR 0.29(95%CI 0.22-0.38,p<0.001)、30天死亡OR 0.40(95%CI 0.32-0.49,p<0.001),均低于低全血组。作者认为将高全血与总输血量比值纳入复苏方案可能改善创伤患者结局,需进一步研究优化输血策略。
要点
- 需大量输血的创伤患者中,全血与总输血量比值≥0.5者24小时死亡OR 0.29(95%CI 0.22-0.38,p<0.001),低于比值<0.5者。
- 高全血组30天死亡OR 0.40(95%CI 0.32-0.49,p<0.001),低于低全血组。
- 研究纳入到院4小时内接受全血输注的≥16岁创伤患者,全血与总输血量比值最佳截断值为0.5。
- 902例中仅143例(15.85%)为高全血组,759例(84.15%)为低全血组。
- 作者认为将高全血与总输血量比值纳入复苏方案可能改善结局,需进一步研究优化输血策略。
适用人群与场景
- 美国国家创伤数据库2020年数据中年龄≥16岁、到院4小时内接受全血输注的创伤患者。
诊断标准与关键阈值
- 以全血与总输血量比值0.5为最佳截断值,≥0.5为高全血组,<0.5为低全血组。
研究设计与关键结果
- 回顾性队列研究,基于美国国家创伤数据库2020年数据,纳入902例需大量输血且到院4小时内接受全血输注的创伤患者,中位年龄34(IQR 24-51)岁,男性783例(86.9%)。
- 高全血组143例(15.85%)vs低全血组759例(84.15%),逆概率治疗加权调整的logistic回归显示高全血组24小时死亡OR 0.29(95%CI 0.22-0.38,p<0.001),低于低全血组。
- 高全血组30天死亡OR 0.40(95%CI 0.32-0.49,p<0.001),低于低全血组。
- 次要结局包括输血相关不良事件。
证据类型、等级与局限
- 证据类型:回顾性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为将高全血与总输血量比值纳入复苏方案可能改善创伤患者结局,需进一步研究优化输血策略。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: Whole blood (WB) resuscitation has been reported to improve haemostasis and reduce mortality in trauma patients with severe haemorrhage. However, the ideal ratio of WB to total transfusion volume (TTV) and whether a high WB to TTV ratio is associated with favourable clinical outcomes for patients with trauma requiring massive transfusion remains unclear. We aimed to investigate the effectiveness of a high WB to TTV ratio in the treatment of patients with trauma requiring massive transfusion and explore the nonlinear relationship between the ratio of WB to TTV and patient's outcomes.
METHODOLOGY: We performed a retrospective cohort study using the National Trauma Data Bank from the USA in 2020. The study included patients aged ≥16 years who received WB transfusion within 4 hours of hospital arrival. Patients were categorised into two groups based on the optimal cut-off value (0.5) of the WB to TTV ratio. The primary outcomes were in-hospital mortality at 24 hours and 30 days. Secondary outcomes included transfusion-related adverse events.
RESULTS: Among the 902 patients (median (IQR) age, 34 (24-51) years; 783 male (86.9%)), the optimal cut-off value for the WB to TTV ratio was 0.5. Based on this cut-off value, 143 patients (15.85%) were classified into the high WB group and 759 (84.15%) into the low WB group. Inverse probability of treatment weighting-adjusted logistic regression demonstrated that the high WB group had lower odds of 24-hour mortality (OR, 0.29; 95% CI 0.22 to 0.38; p<0.001) and 30-day mortality (OR, 0.40; 95% CI 0.32 to 0.49; p<0.001) compared with the low WB group.
CONCLUSION: A high WB to TTV ratio was associated with reduced mortality in patients with trauma requiring massive transfusion. These findings suggested that incorporating a high WB to TTV ratio into resuscitation protocols may improve outcomes for patients with trauma, warranting further research to optimise transfusion strategies.
参考来源
- Peng C, Zhu R, Yang F, et al. High whole blood to total transfusion volume ratio and survival outcomes in patients with trauma requiring massive transfusions. Emerg Med J. 2025. PMID: 40789646. doi:10.1136/emermed-2025-215051
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。