水上救援艇行进中口对口、袖珍面罩或i-gel®通气对心肺复苏的影响:一项先导研究
该随机交叉先导研究纳入16名受过训练救生员,在20节航行的充气救生艇上对复苏模型分别采用口对口(MM)、袖珍面罩(PM)和i-gel®声门上气道(IG)三种通气方式行心肺复苏。MM启动心肺复苏时间中位4秒,短于PM的8秒和IG的14秒;IG启动通气显著晚于MM(p<0.001)和IG(p=0.006,原文此处写作IG,按上下文应为PM)。三种方式的有效通气次数和平均通气量无显著差异(p>0.05)。作者认为,MM或PM等简单策略在模型上通气效果与IG相当,且能更快速启动心肺复苏。
要点
- 20节航行救生艇上,口对口通气启动心肺复苏中位时间4秒,短于袖珍面罩8秒和i-gel®14秒。
- i-gel®启动通气显著晚于口对口(p<0.001),也显著晚于袖珍面罩(p=0.006,原文此处写作IG,按上下文应为PM)。
- 三种通气方式的有效通气次数和平均通气量无显著差异(p>0.05)。
- 研究为16名救生员的随机交叉先导研究,在复苏模型上完成,非真实心脏骤停患者。
适用人群与场景
- 16名受过训练的救生员,在20节航行的充气救生艇上对复苏模型实施心肺复苏。
研究设计与关键结果
- 随机交叉先导研究,16名救生员,在20节航行的充气救生艇上对复苏模型分别采用口对口、袖珍面罩和i-gel®三种通气方式行心肺复苏。
- 启动心肺复苏中位时间:口对口4秒,袖珍面罩8秒,i-gel®14秒。
- i-gel®启动通气显著晚于口对口(p<0.001),也显著晚于袖珍面罩(p=0.006,原文此处写作IG,按上下文应为PM)。
- 有效通气次数和平均通气量在三种方法间无显著差异(p>0.05)。
证据类型、等级与局限
- 证据类型:随机交叉先导研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,口对口或袖珍面罩等简单策略在模型上通气效果与i-gel®相当,且能在航行救生艇上更快速启动心肺复苏。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: The use of Inflatable Rescue Boats (IRBs) for cardiopulmonary resuscitation (CPR) in aquatic environments presents unique challenges due to their inherent instability and technical limitations. Despite the critical role of effective ventilation in cardiac arrest, there is a significant knowledge gap regarding optimal strategies to achieve this on IRBs.
AIM: To compare the effectiveness of three ventilation methods-Mouth-to-Mouth (MM), Pocket Mask (PM), and i-gel® supraglottic airway device (IG)-in initiating CPR on a moving IRB.
METHODS: A randomized crossover pilot study was conducted with 16 trained lifeguards. Each participant performed CPR using the three ventilation methods on a resuscitation manikin with the IRB under power (cruising) at 20 knots. The study measured the time to initiate CPR and resuscitation skills, including ventilations and chest compressions.
RESULTS: The MM method resulted in the shortest time to initiate CPR, with a median of 4 s, compared to PM and IG, which had medians of 8 and 14 s, respectively. IG was significantly later in initiating ventilation compared to MM (p < 0.001) and IG (p = 0.006). No significant differences were observed in the number of effective ventilations or average ventilation volume among the methods (p > 0.05).
CONCLUSIONS: Simple strategies such as MM or PM provide ventilations that are just as effective as those using IG in manikins and allow for faster initiation of CPR while under power in an IRB.
参考来源
- Carracedo-Rodríguez E, Webber J, Fernández-Méndez M, et al. Mouth-to-mouth, pocket mask, or i-gel® resuscitation on a moving rescue boat: How do different ventilation methods affect CPR? A pilot study. Am J Emerg Med. 2025. PMID: 40882489. doi:10.1016/j.ajem.2025.07.026