文献速递复苏、休克与脓毒症

不同胸外按压频率对家猪心肺复苏结局的影响

[The impact of different chest compression frequencies on cardiopulmonary resuscitation outcomes in domestic pigs].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2025-01-01
一句话结论在60–140次/分范围内,120次/分胸外按压在猪心搏骤停模型中血流动力学和复苏结局最优,但组间频率间隔宽,需进一步研究确定最佳频率范围。

该研究将40头健康雄性家猪随机分为60、80、100、120、140次/分五组(每组8头),建立室颤心搏骤停模型,按指定频率进行胸外按压(深度5 cm),全程未使用肾上腺素等药物。随按压频率增加,除颤次数和累计除颤能量显著下降,120次/分组最低(除颤2.25±0.71次、能量450.00±141.42 J),140次/分组再次升高;呼气末二氧化碳分压、按压前主动脉压和冠脉灌注压同样在120次/分组达峰值,140次/分组回落。自主循环恢复、复苏成功和24小时存活动物数在120次/分组最多(分别为7、7、7头),140次/分组减少(分别为3、3、2头);电镜下100和120次/分组脑组织超微结构损伤明显减轻。作者结论为120次/分在此模型中血流动力学和结局最有利,但因组间频率间隔宽,需进一步研究以更精确确定最佳按压频率范围。

要点

  • 在60–140次/分范围内,120次/分胸外按压的家猪除颤次数最少(2.25±0.71次)、累计除颤能量最低(450.00±141.42 J),140次/分再次升高(4.75±1.04次、950.00±207.02 J)。
  • 120次/分组呼气末二氧化碳分压(18.69±1.98 mmHg)、按压前主动脉压(95.13±7.06 mmHg)和冠脉灌注压(14.88±6.92 mmHg)均高于60次/分组(分别为8.67±1.30、71.00±6.41、8.57±3.42 mmHg)。
  • 120次/分组自主循环恢复、复苏成功和24小时存活动物数均为7头,60次/分组分别为2、2、1头,140次/分组分别为3、3、2头。
  • 电镜下60、80、140次/分组脑组织核膜不规则不完整、核仁不清、线粒体肿胀伴嵴减少和形态异常,100和120次/分组超微结构损伤明显减轻。
  • 作者指出组间频率间隔宽,需进一步研究以更精确确定最佳按压频率范围。

适用人群与场景

  • 健康雄性家猪心搏骤停模型,经右颈外静脉心内膜刺激电极以交流电诱发室颤导致心搏骤停。
  • 所有动物接受标准麻醉和气管插管,经左股动脉置管至胸主动脉监测主动脉压,经右颈外静脉置管至右心房监测右心房压。

处置流程与药物剂量

  • 室颤诱发心搏骤停后1分钟开始人工胸外按压,按分组频率(60、80、100、120或140次/分)进行,按压深度5 cm。
  • 心肺复苏2分钟后进行首次除颤;整个复苏过程未给予肾上腺素或其他药物。
  • 从室颤诱发前1分钟至自主循环恢复后10分钟动态监测主动脉压、冠脉灌注压和呼气末二氧化碳分压;自主循环恢复后24小时用透射电镜观察脑皮质超微结构。

研究设计与关键结果

  • 研究类型为动物实验,40头健康雄性家猪随机分为60、80、100、120、140次/分五组,每组8头。
  • 随按压频率增加,除颤次数和累计除颤能量显著下降,120次/分组最低:除颤次数从60次/分组的(4.88±0.83)次降至120次/分组的(2.25±0.71)次,能量从(975.00±166.90)J降至(450.00±141.42)J;140次/分组再次升高至(4.75±1.04)次和(950.00±207.02)J,组间差异均有统计学意义(均P<0.01)。
  • 随按压频率增加,呼气末二氧化碳分压、按压前主动脉压和冠脉灌注压显著改善,120次/分组达峰值:与60次/分组比较,呼气末二氧化碳分压(mmHg)18.69±1.98 vs. 8.67±1.30,主动脉压(mmHg)95.13±7.06 vs. 71.00±6.41,冠脉灌注压(mmHg)14.88±6.92 vs. 8.57±3.42;140次/分组上述值再次下降,分别为(10.59±1.40)、(72.38±11.49)和(10.36±4.57)mmHg,组间差异均有统计学意义(均P<0.01)。
  • 自主循环恢复、复苏成功和24小时存活动物数随按压频率增加而增加,120次/分组达峰值:与60次/分组比较,自主循环恢复7头 vs. 2头,复苏成功7头 vs. 2头,24小时存活7头 vs. 1头;140次/分组自主循环恢复、复苏成功和24小时存活分别为3、3、2头。
  • 透射电镜显示60、80、140次/分组脑组织核膜不规则且不完整、核仁不清、线粒体肿胀伴嵴减少和形态异常;100和120次/分组超微结构损伤明显减轻。

证据类型、等级与局限

  • 证据类型为动物实验(家猪心搏骤停模型)。
  • 局限:组间按压频率间隔宽,需进一步研究以更精确确定最佳按压频率范围。

对床旁实践的改变

  • 作者认为,在测试的60–140次/分胸外按压频率中,120次/分在猪心搏骤停心肺复苏模型中血流动力学和结局最有利。
  • 作者指出,由于组间频率间隔宽,需进一步研究以更精确确定最佳按压频率范围。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To compare the effects of different chest compression rates (60-140 times/min) on hemodynamic parameters, return of spontaneous circulation (ROSC), resuscitation success, and survival in a porcine model of cardiac arrest (CA) followed by cardiopulmonary resuscitation (CPR).

METHODS: Forty healthy male domestic pigs were randomly divided into five groups based on chest compression rate: 60, 80, 100, 120, and 140 times/min (n = 8). All animals underwent standard anesthesia and tracheal intubation. A catheter was inserted via the left femoral artery into the thoracic aorta to monitor aortic pressure (AOP), and another via the right external jugular vein into the right atrium to monitor right atrial pressure (RAP). In each group, animals were implanted with a stimulating electrode via the right external jugular vein to the endocardium, and ventricular fibrillation (VF) was induced by delivering alternating current stimulation, resulting in CA. After a 1-minute, manual chest compressions were performed at the assigned rate with a compression depth of 5 cm. The first defibrillation was delivered after 2 minutes of CPR. No epinephrine or other pharmacologic agents were administered during the entire resuscitation process. From 1 minute before VF induction to 10 minutes after ROSC, dynamic monitoring of AOP, coronary perfusion pressure (CPP), and partial pressure of end-tidal carbon dioxide (PETCO2). Cortical ultrastructure was examined 24 hours post-ROSC using transmission electron microscopy.

RESULTS: With increasing compression rates, both the total number of defibrillations and cumulative defibrillation energy significantly decreased, reaching their lowest levels in the 120 times/min group. The number of defibrillations decreased from (4.88±0.83) times in the 60 times/min group to (2.25±0.71) times in the 120 compressions/min group, and energy from (975.00±166.90)J to (450.00±141.42)J. However, both parameters increased again in the 140 times/min group [(4.75±1.04)times, (950.00±207.02)J], the differences among the groups were statistically significant (both P < 0.01). As compression frequency increased, PETCO2, pre-defibrillation AOP and CPP significantly improved, peaking in the 120 times/min group [compared with the 60 times/min group, PETCO2 (mmHg, 1 mmHg≈0.133 kPa): 18.69±1.98 vs. 8.67±1.30, AOP (mmHg): 95.13±7.06 vs. 71.00±6.41, CPP (mmHg): 14.88±6.92 vs. 8.57±3.42]. However, in the 140 times/min group, these values declined significantly again [PETCO2, AOP, and CPP were (10.59±1.40), (72.38±11.49), and (10.36±4.57) mmHg, respectively], the differences among the groups were statistically significant (all P < 0.01). The number of animals achieving ROSC, successful resuscitation, and 24-hour survival increased with higher compression rates, reaching a peak in the 120 times/min group (compared with the 60 times/min group, ROSC: 7 vs. 2, successful resuscitation: 7 vs. 2, 24-hour survival: 7 vs.1), then decreased again in the 140 times/min group (the animals that ROSC, successfully recovered and survived for 24 hours were 3, 3, and 2, respectively). Transmission electron microscopy revealed that in the 60, 80, and 140 times/min groups, nuclear membranes in cerebral tissue were irregular and incomplete, nucleoli were indistinct, and mitochondria were swollen with reduced cristae and abnormal morphology. In contrast, the 100 times/min and 120 times/min groups exhibited significantly attenuated ultrastructural damage.

CONCLUSIONS: Among the tested chest compression rates of 60-140 times/min, a chest compressions frequency of 120 times/min is the most favorable hemodynamic profile and outcomes during CPR in a porcine CA model. However, due to the wide spacing between groups, further investigation is needed to determine the optimal compression rate range more precisely.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Xu N, Zhang J, Luo J, et al. [The impact of different chest compression frequencies on cardiopulmonary resuscitation outcomes in domestic pigs]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2025. PMID: 40819948. doi:10.3760/cma.j.cn121430-20250124-00083

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。