文献速递心脑血管急症重症综合管理与镇静镇痛

心脏肌钙蛋白用于院外心脏骤停后患者急性心肌梗死诊断的价值

Cardiac troponin for the diagnosis of acute myocardial infarction in patients after out-of-hospital cardiac arrest.
PubMed 文献 · Resuscitation · 2025-08-15
一句话结论在院外心脏骤停幸存者中,肌钙蛋白诊断急性心肌梗死的价值不足,用其确定骤停病因会导致急性心肌梗死过度诊断。

该研究纳入618例存活出院的院外心脏骤停患者,盲法评估病历以确定急性心肌梗死诊断,并分析高敏肌钙蛋白T和肌钙蛋白I。结果发现ST段抬高型心肌梗死179例(29%)、非ST段抬高型心肌梗死77例(13%)、无急性心肌梗死362例(59%)。以超过4倍正常参考值上限诊断任何急性心肌梗死,特异度74%(95%CI 69-79)、阳性预测值60%(95%CI 53-68);以不超过1倍正常参考值上限排除任何急性心肌梗死,敏感度95%(95%CI 92-98)、阴性预测值83%(95%CI 72-94)。作者结论认为肌钙蛋白对院外心脏骤停患者急性心肌梗死的诊断价值不足,用于确定骤停病因会导致过度诊断。

要点

  • 在618例存活出院的院外心脏骤停患者中,ST段抬高型心肌梗死179例(29%)、非ST段抬高型心肌梗死77例(13%)、无急性心肌梗死362例(59%)。
  • 以超过4倍正常参考值上限诊断任何急性心肌梗死,特异度74%(95%CI 69-79)、阳性预测值60%(95%CI 53-68)。
  • 以不超过1倍正常参考值上限排除任何急性心肌梗死,敏感度95%(95%CI 92-98)、阴性预测值83%(95%CI 72-94)。
  • ST段抬高型心肌梗死与非ST段抬高型心肌梗死患者首次高敏肌钙蛋白T差异有统计学意义(p≤0.001),非ST段抬高型心肌梗死与无急性心肌梗死患者间差异亦有统计学意义(p=0.013)。
  • 在无急性心肌梗死患者中,电击次数(p<0.001)和自主循环恢复时间(p<0.001)与高敏肌钙蛋白T峰值显著相关。

适用人群与场景

  • 存活出院的院外心脏骤停患者。

诊断标准与关键阈值

  • 急性心肌梗死诊断由研究者盲法评估病历确定,未依赖肌钙蛋白结果。
  • 以超过4倍正常参考值上限作为诊断任何急性心肌梗死的阈值。
  • 以不超过1倍正常参考值上限作为排除任何急性心肌梗死的阈值。

研究设计与关键结果

  • 研究类型为诊断准确性研究,纳入618例存活出院的院外心脏骤停患者,分析高敏肌钙蛋白T和肌钙蛋白I。
  • ST段抬高型心肌梗死179例(29%)、非ST段抬高型心肌梗死77例(13%)、无急性心肌梗死362例(59%)。
  • ST段抬高型心肌梗死与非ST段抬高型心肌梗死患者首次高敏肌钙蛋白T差异有统计学意义(p≤0.001),非ST段抬高型心肌梗死与无急性心肌梗死患者间差异亦有统计学意义(p=0.013)。
  • 以超过4倍正常参考值上限诊断任何急性心肌梗死,特异度74%(95%CI 69-79)、阳性预测值60%(95%CI 53-68)。
  • 以不超过1倍正常参考值上限排除任何急性心肌梗死,敏感度95%(95%CI 92-98)、阴性预测值83%(95%CI 72-94)。
  • ST段抬高型心肌梗死与非ST段抬高型心肌梗死诊断的ROC曲线下面积分别为0.772(95%CI 0.721-0.824)和0.657(95%CI 0.575-0.740),ST段抬高型心肌梗死与非ST段抬高型心肌梗死比较的ROC曲线下面积为0.649(95%CI 0.561-0.738)。
  • 在无急性心肌梗死患者中,电击次数(p<0.001)和自主循环恢复时间(p<0.001)与高敏肌钙蛋白T峰值显著相关。

证据类型、等级与局限

  • 证据类型为诊断准确性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者结论认为肌钙蛋白对院外心脏骤停患者急性心肌梗死的诊断价值不足,使用肌钙蛋白确定骤停病因会导致急性心肌梗死过度诊断。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: After out-of-hospital cardiac arrest (OHCA), global ischemia may cause cardiac troponin (cTn) elevation and false-positive diagnoses of acute myocardial infarction (AMI). We determined the diagnostic value of cTn to diagnose AMI in OHCA patients.

METHODS: OHCA patients who survived to discharge were included. Hospital records were assessed, blinded to cTn, to determine the diagnosis AMI. High-sensitivity troponin T (hs-TnT) and troponin I (TnI) were analysed.

RESULTS: Of 618 patients, ST-elevation MI (STEMI) was diagnosed in 179 patients (29 %), non-ST elevation MI (NSTEMI) in 77 patients (13 %) and 362 patients (59 %) had no AMI. There was a significant difference in first hs-TnT between STEMI and NSTEMI patients (p ≤ 0.001) and between NSTEMI patients and patients without AMI (p = 0.013). To rule in any AMI (exceeding 4 × upper reference limit of normal (URL), specificity was 74 % (95 % CI 69-79) and positive predictive value 60 % (95 % CI 53-68). To rule out any AMI (not exceeding 1× URL), sensitivity was 95 % (95 % CI 92-98) and negative predictive value 83 % (95 % CI 72-94). AUC of the ROC curves of STEMI and NSTEMI, vs. no AMI were 0.772(95 % CI 0.721-0.824), 0.657(95 % CI 0.575-0.740) respectively and STEMI vs. NSTEMI 0.649(95 % CI 0.561-0.738). Number of shocks (p < 0.001) and time until return of spontaneous circulation (p < 0.001) were significantly correlated to peak hs-TnT in patients without AMI.

CONCLUSIONS: cTn has insufficient diagnostic value for AMI in OHCA patients. Use of cTn to establish the cause of OHCA results in overdiagnosis of AMI.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Verkaik BJ, van der Werf C, Fischer JC, et al. Cardiac troponin for the diagnosis of acute myocardial infarction in patients after out-of-hospital cardiac arrest. Resuscitation. 2025. PMID: 40819815. doi:10.1016/j.resuscitation.2025.110774

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。