人工智能辅助图像判读对临床医生在胸部X线片上识别气管插管位置诊断性能的影响:多病例多阅片者研究

Evaluation of the impact of artificial intelligence-assisted image interpretation on the diagnostic performance of clinicians in identifying endotracheal tube position on plain chest X-ray: a multi-case multi-reader study.
PubMed 文献 · Crit Care · 2025-07-28
一句话结论在成人插管患者胸片判读中,AI辅助使气管插管位置分类准确率从73.6%升至77.4%,危重错位识别准确率从79.3%升至89.0%。

本研究回顾性纳入来自John Radcliffe医院(牛津)及另外两家英国NHS医院的400张插管成人患者胸片,由胸科放射科医师共识分类(位置正确、过低[远端]、过高[近端])作为参考标准,正确位置定义为导管尖端位于隆突上方3-7 cm。来自四家NHS医院、六个临床专科的18名不同年资临床读者在在线平台上对每张图像进行盲法判读,洗脱期四周后借助AI辅助图像判读工具重复判读,共完成14,400次图像判读。AI辅助使插管位置分类汇总准确率从73.6%提升至77.4%(p=0.002),危重错位识别准确率从79.3%提升至89.0%(p=0.001),读者信心提升,平均判读时间维持36秒/张不变。作者认为AI辅助可能作为支持临床医生在胸片上识别插管错位的有用辅助手段。

要点

  • 危重错位插管识别准确率在AI辅助下从79.3%升至89.0%(p=0.001),为本次研究中获益最明显的判读场景。
  • 插管位置分类汇总准确率从73.6%升至77.4%(p=0.002),AI辅助带来小幅但统计学显著的提升。
  • AI辅助后读者判读信心提升,平均判读时间保持36秒/张不变。
  • 参考标准由胸科放射科医师共识分类确定,正确位置定义为导管尖端位于隆突上方3-7 cm。
  • 作者认为AI辅助可能作为临床医生在胸片上识别插管错位的有用辅助手段。

适用人群与场景

  • 插管成人患者的胸片,图像来自重症监护病房(ICU)和急诊科(ED)等多种临床场景。

诊断标准与关键阈值

  • 正确气管插管位置定义为导管尖端位于隆突上方3-7 cm,与现有指南一致。
  • 参考标准分类为位置正确、过低(远端)或过高(近端),由胸科放射科医师共识确定。

研究设计与关键结果

  • 研究类型为多病例多阅片者研究,回顾性纳入400张插管成人患者胸片,来自John Radcliffe医院(牛津)及另外两家英国NHS医院,共完成14,400次图像判读。
  • 18名来自四家NHS医院、六个临床专科的不同年资临床读者参与,洗脱期四周后借助AI辅助工具重复判读。
  • 插管位置分类汇总准确率从73.6%升至77.4%(p=0.002)。
  • 危重错位插管识别准确率从79.3%升至89.0%(p=0.001)。
  • AI辅助后读者信心提升,平均判读时间保持36秒/张不变。

证据类型、等级与局限

  • 证据类型为多病例多阅片者研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为AI辅助可能作为支持临床医生在胸片上识别插管错位的有用辅助手段。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Incorrectly placed endotracheal tubes (ETTs) can lead to serious clinical harm. Studies have demonstrated the potential for artificial intelligence (AI)-led algorithms to detect ETT placement on chest X-Ray (CXR) images, however their effect on clinician accuracy remains unexplored. This study measured the impact of an AI-assisted ETT detection algorithm on the ability of clinical staff to correctly identify ETT misplacement on CXR images.

METHODS: Four hundred CXRs of intubated adult patients were retrospectively sourced from the John Radcliffe Hospital (Oxford) and two other UK NHS hospitals. Images were de-identified and selected from a range of clinical settings, including the intensive care unit (ICU) and emergency department (ED). Each image was independently reported by a panel of thoracic radiologists, whose consensus classification of ETT placement (correct, too low [distal], or too high [proximal]) served as the reference standard for the study. Correct ETT position was defined as the tip located 3-7 cm above the carina, in line with established guidelines. Eighteen clinical readers of varying seniority from six clinical specialties were recruited across four NHS hospitals. Readers viewed the dataset using an online platform and recorded a blinded classification of ETT position for each image. After a four-week washout period, this was repeated with assistance from an AI-assisted image interpretation tool. Reader accuracy, reported confidence, and timings were measured during each study phase.

RESULTS: 14,400 image interpretations were undertaken. Pooled accuracy for tube placement classification improved from 73.6 to 77.4% (p = 0.002). Accuracy for identification of critically misplaced tubes increased from 79.3 to 89.0% (p = 0.001). Reader confidence improved with AI assistance, with no change in mean interpretation time at 36 s per image.

CONCLUSION: Use of assistive AI technology improved accuracy and confidence in interpreting ETT placement on CXR, especially for identification of critically misplaced tubes. AI assistance may potentially provide a useful adjunct to support clinicians in identifying misplaced ETTs on CXR.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Novak A, Ather S, Morgado ATE, et al. Evaluation of the impact of artificial intelligence-assisted image interpretation on the diagnostic performance of clinicians in identifying endotracheal tube position on plain chest X-ray: a multi-case multi-reader study. Crit Care. 2025. PMID: 40722100. doi:10.1186/s13054-025-05566-6