两种预氧合方式与气管插管期间低氧血症的关联:一项二次分析
本研究为两项急诊气管插管随机试验的二次分析,纳入1156例危重患者,其中136例采用球囊面罩装置预氧合,1020例采用非重复呼吸面罩氧预氧合。主要终点为麻醉诱导至气管插管后2分钟内外周血氧饱和度<85%。球囊面罩组低氧血症发生率为14.7%(20/136),面罩氧组为15.0%(153/1020)。多变量分析显示,球囊面罩预氧合与面罩氧预氧合相比,低氧血症的调整比值比为1.22(95%CI 0.72–2.16),两组无显著差异。结论认为,在危重患者气管插管中,球囊面罩预氧合并未较面罩氧预氧合降低低氧血症风险。
要点
- 在1156例急诊气管插管危重患者中,球囊面罩预氧合组低氧血症发生率为14.7%(20/136),面罩氧组为15.0%(153/1020)。
- 多变量分析显示,球囊面罩预氧合与面罩氧预氧合相比,低氧血症的调整OR为1.22(95%CI 0.72–2.16),无显著差异。
- 低氧血症定义为麻醉诱导至气管插管后2分钟内外周血氧饱和度<85%。
- 研究为两项随机试验的二次分析,采用倾向加权多变量logistic回归模型比较两组低氧血症发生率。
适用人群与场景
- 急诊科和重症监护病房中接受紧急气管插管的危重患者。
诊断标准与关键阈值
- 低氧血症定义:麻醉诱导至气管插管后2分钟内,外周血氧饱和度<85%。
研究设计与关键结果
- 研究类型:两项急诊气管插管随机试验的二次分析,样本量1156例,其中球囊面罩预氧合组136例,面罩氧预氧合组1020例。
- 主要终点:低氧血症(外周血氧饱和度<85%)发生率在球囊面罩组为14.7%(20/136),面罩氧组为15.0%(153/1020)。
- 多变量分析:球囊面罩预氧合与面罩氧预氧合相比,低氧血症的调整OR为1.22(95%CI 0.72–2.16),无显著差异。
证据类型、等级与局限
- 证据类型:随机试验的二次分析。
- 局限:原文未报告局限性。
对床旁实践的改变
- 对于急诊科和ICU接受紧急气管插管的危重患者,选择球囊面罩装置或面罩氧进行预氧合,低氧血症风险无显著差异。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
STUDY OBJECTIVES: Oxygen masks (bag-valve-mask device and nonrebreathing facemask oxygen) are the most common method of preoxygenation in critically ill patients undergoing emergency tracheal intubation in the emergency department and intensive care unit. Whether the type of oxygen mask used for preoxygenation alters the risk of hypoxemia during intubation is uncertain. We sought to compare the incidence of hypoxemia during intubation in patients preoxygenated with a bag-valve-mask device to the incidence of hypoxemia in patients preoxygenated with facemask oxygen.
METHODS: We conducted a secondary analysis of 2 randomized trials of emergency tracheal intubation. The primary outcome of hypoxemia was defined as a peripheral oxygen saturation <85% between induction of anesthesia and 2 minutes after tracheal intubation. We used a propensity-weighted multivariable logistic regression model to compare the incidence of hypoxemia between groups. We hypothesized that preoxygenation with a bag-valve-mask device would be associated with a lower incidence of hypoxemia compared to preoxygenation with facemask oxygen.
RESULTS: We included 1,156 patients in this analysis, of whom 136 were preoxygenated with a bag-valve-mask device and 1,020 were preoxygenated with facemask oxygen. Hypoxemia occurred in 20 of 136 (14.7%) participants in the bag-valve-mask device group and 153 of 1,020 (15.0%) participants in the facemask oxygen group. In the multivariable analysis, participants preoxygenated with a bag-valve-mask device had similar odds of hypoxemia to those preoxygenated with facemask oxygen (adjusted odds ratio 1.22, 95% confidence interval 0.72 to 2.16).
CONCLUSION: In critically ill patients undergoing tracheal intubation, preoxygenation with a bag-valve-mask device did not reduce the risk of hypoxemia compared to preoxygenation with facemask oxygen.