儿童创伤性气胸初始胸片大小与观察失败独立相关
单中心回顾性研究纳入2010至2023年一家1级儿童创伤中心收治的18岁及以下创伤性气胸患儿,排除无胸片及置管后转入者,共313例儿童358次气胸事件。观察定义为已知气胸但未置管继续治疗,观察失败定义为初始观察后行胸腔置管;接受观察者中45例(13.5%)失败。失败者初始气胸更大(14.1% vs 6.5%,p<0.001),入院低血压、血气胸、吸氧方式及PICU入住比例更高。胸片预测需置管的最佳气胸大小为12.5%(AUROC 0.715);多变量回归控制机械通气、血气胸和低血压后,仅大小≥12.5%与观察失败相关。
要点
- 儿童创伤性气胸接受观察者中45/313例(13.5%)观察失败需胸腔置管。
- 观察失败者初始胸片气胸体积大于观察成功者(14.1% vs 6.5%,p<0.001)。
- 胸片预测需胸腔置管的最佳气胸界值为12.5%(AUROC 0.715)。
- 多变量回归控制机械通气、血气胸、低血压后,仅气胸≥12.5%与观察失败独立相关。
- 作者认为较小创伤性气胸预防性胸腔置管可能不必要,应考虑观察。
适用人群与场景
- 18岁及以下、到1级儿童创伤中心就诊的创伤性气胸患儿,研究期间为2010至2023年。
- 排除无胸片者及置管后转入者。
诊断标准与关键阈值
- 观察:已知创伤性气胸但未行胸腔置管而继续治疗。
- 观察失败:初始观察后行胸腔置管。
- 气胸大小用Collins体积法在初始胸片上估算。
- 预测需胸腔置管的最佳胸片气胸大小为12.5%(AUROC 0.715)。
红旗征与不能漏的情况
- 观察失败者更常见入院时低血压(26.7% vs 10.2%,p=0.006)。
- 观察失败者更常见血气胸(22.2% vs 3.5%,p<0.001)。
- 观察失败者更常入住儿科重症监护病房(47.4% vs 30.6%,p=0.008)。
研究设计与关键结果
- 单中心回顾性研究,313例儿童共358次创伤性气胸事件;接受观察者中45例(13.5%)失败。
- 观察失败者初始气胸体积大于未失败者(14.1% vs 6.5%,p<0.001)。
- 观察失败者入院低血压比例26.7% vs 10.2%(p=0.006),血气胸22.2% vs 3.5%(p<0.001),PICU入住47.4% vs 30.6%(p=0.008)。
- 吸氧方式分布:鼻导管33.3% vs 11.1%,非重复呼吸面罩37.8% vs 58.5%,机械通气15.6% vs 10.7%(总体p<0.001)。
- 多变量回归控制气胸≥12.5%、机械通气、血气胸和低血压后,仅气胸大小≥12.5%与观察失败相关。
证据类型、等级与局限
- 研究类型:单中心回顾性研究。
- 证据等级:治疗/管理,Level III。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,较小创伤性气胸患儿预防性胸腔置管可能不必要,应考虑观察。
- 对胸片Collins法气胸≥12.5%的儿童,观察失败风险独立升高,需据此权衡置管与观察策略。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Traumatic pneumothorax (tPTX) in children is typically treated with tube thoracostomy (TT). We aimed to determine if the size of tPTX on initial chest x-ray (CXR) was associated with a need for TT and failure of observation without TT.
METHODS: We performed a single-institution retrospective review of children (18 years or younger) presenting to a Level 1 pediatric trauma center between 2010 and 2023 with tPTX, excluding children without CXR and those transferred after TT. Observation was defined as progression in care with known tPTX but without TT; failed observation was defined as TT after initial observation. The volumetric Collins method was used to estimate size of tPTX on CXR. Area under the receiver operating characteristic curve (AUROC), Youden's index, and multivariable regression analyses were performed.
RESULTS: There were 313 children with 358 instances of tPTX; of those undergoing observation, 45 (13.5%) failed. Those who failed observation had larger tPTX (14.1% vs. 6.5%, p < 0.001) and more frequently were hypotensive on arrival (26.7% vs. 10.2%, p = 0.006), had hemopneumothorax (22.2% vs. 3.5%, p < 0.001), received supplemental oxygenation (nasal cannula, 33.3% vs. 11.1%; nonrebreather, 37.8% vs. 58.5%; ventilated, 15.6% vs. 10.7%; overall p < 0.001), and were admitted to the pediatric intensive care unit (47.4% vs. 30.6%, p = 0.008). Optimal size predicting need for TT placement on CXR was 12.5% (AUROC 0.715). On multivariable regression controlling for tPTX size ≥12.5%, mechanical ventilation, hemopneumothorax, and hypotension, only size ≥12.5% was associated with failure of observation.
CONCLUSION: In children observed with tPTX, Collins size of ≥12.5% on CXR was independently associated with failure. In children with smaller tPTX, prophylactic TT placement may not be necessary, and observation should be considered.
LEVEL OF EVIDENCE: Therapeutic/Care Management; Level III.
参考来源
- Srinivas S, Rachwal B, Bergus KC, et al. Size of traumatic pneumothorax on initial chest x-ray is independently associated with failed observation in children. J Trauma Acute Care Surg. 2025. PMID: 40604364. doi:10.1097/TA.0000000000004638
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。