文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

吸入一氧化氮对ARDS患者通气/灌注匹配的影响:电阻抗断层成像的前瞻性观察研究

Effects of inhaled nitric oxide on ventilation/perfusion mismatch assessed by electrical impedance tomography in patients with ARDS: a prospective observational study.
PubMed 文献 · Crit Care · 2025-07-27
一句话结论单中心前瞻性生理学研究显示,ARDS患者吸入5 ppm一氧化氮后30分钟仅36.7%(11/30)为反应者,反应者EIT示肺灌注向腹侧重新分布、全肺仅灌注单元及不匹配单元比例降低。

该单中心前瞻性生理学研究纳入机械通气的ARDS患者,初始给予5 ppm吸入一氧化氮,30分钟时PaO2/FiO2提升≥20%者为反应者并维持该剂量,非反应者每30分钟剂量加倍至最高40 ppm直至达标,试验持续3小时。30分钟时36.7%(11/30)患者为反应者,与较年轻年龄和较低高血压患病率相关。反应者3小时时腹侧灌注比例显著增加(30分钟已可见),30分钟时背侧仅灌注单元比例显著降低,全肺水平仅灌注单元和不匹配单元比例降低;非反应者在延长高剂量吸入一氧化氮后3小时背侧和全肺仅灌注单元比例较基线增加。

要点

  • 机械通气ARDS患者吸入5 ppm一氧化氮,30分钟时36.7%(11/30)达到PaO2/FiO2提升≥20%的反应标准。
  • 反应者在30分钟即出现腹侧灌注比例增加,3小时时该变化持续存在。
  • 反应者30分钟时背侧仅灌注单元比例显著降低,全肺仅灌注单元和不匹配单元比例降低。
  • 非反应者在延长高剂量吸入一氧化氮后3小时,背侧和全肺仅灌注单元比例较基线增加。
  • 反应者与较年轻年龄和较低高血压患病率相关。

适用人群与场景

  • 单中心、前瞻性生理学研究纳入的机械通气ARDS患者。

诊断标准与关键阈值

  • 反应者定义为吸入一氧化氮后30分钟PaO2/FiO2提升≥20%。

处置流程与药物剂量

  • 所有患者初始吸入5 ppm一氧化氮;反应者维持该剂量,非反应者每30分钟剂量加倍,最高至40 ppm,直至PaO2/FiO2提升≥20%。
  • 试验持续3小时,于基线(0小时)、吸入一氧化氮后30分钟和3小时采集EIT数据及临床呼吸和血流动力学参数。

研究设计与关键结果

  • 30分钟时36.7%(11/30)患者为反应者,反应者与较年轻年龄和较低高血压患病率相关。
  • 反应者3小时时腹侧灌注比例显著增加,该变化在30分钟已观察到;30分钟时背侧仅灌注单元比例显著降低,全肺水平仅灌注单元和不匹配单元比例降低。
  • 非反应者在延长高剂量吸入一氧化氮后3小时,背侧和全肺仅灌注单元比例较基线增加。

证据类型、等级与局限

  • 证据类型:单中心、前瞻性生理学研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在反应者中EIT显示肺灌注可能向腹侧区域重新分布,全肺仅灌注单元和不匹配单元比例降低。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Our study aimed to assess the effects of inhaled nitric oxide (iNO) on ventilation/perfusion mismatch, and individual variability in patients with acute respiratory distress syndrome (ARDS) by electrical impedance tomography (EIT).

METHODS: This single-center, prospective physiological study enrolled mechanically ventilated ARDS patients. All patients initially received 5 ppm iNO; responders (≥ 20% increase in PaO2/FiO2 at 30 min) maintained this dose, while non-responders had their dose doubled every 30 min, up to 40 ppm, until achieving a ≥ 20% improvement. The trial lasted 3 h. EIT data and clinical respiratory and hemodynamic parameters were collected at baseline (0 h), and at 30 min and 3 h after iNO initiation.

RESULTS: At 30 min, 36.7% (11/30) of patients responded, associated with younger age and lower prevalence of hypertension. Among responders, the proportion of ventral perfusion significantly increased at 3 h, with this change already observed at 30 min. Responders also showed a significant reduction in the proportion of only perfused units in the dorsal region at 30 min; at the whole-lung level, the proportions of only perfused units and unmatched units decreased. In contrast, non-responders showed an increased proportion of only perfused units in both the dorsal region and whole lung at 3 h compared to baseline, following prolonged high-dose iNO administration.

CONCLUSIONS: The response to iNO varied. In responders, EIT showed a potential redistribution of lung perfusion toward ventral regions, with reductions in the proportions of only perfused units and unmatched units in the whole lung.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Zhang H, Gao X, Wu Y, et al. Effects of inhaled nitric oxide on ventilation/perfusion mismatch assessed by electrical impedance tomography in patients with ARDS: a prospective observational study. Crit Care. 2025. PMID: 40717064. doi:10.1186/s13054-025-05543-z

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。