评估机械通气患者潮气量设定公式的普适性:观察性、多队列、回顾性研究
该观察性、多队列、回顾性研究比较了ARMA试验用预测体重(PBW)与全球肺功能倡议2012(GLI 2012)肺量计参考方程计算的预测用力肺活量(PFVC)作为伤前肺容积代理的差异。纳入MIMIC-IV的9152例和eICU-CRD的12420例接受肺保护性通气、低氧血症、身高150-210 cm的患者。结果显示,在相同PBW下,年轻、男性、白人患者的PFVC大于年老、女性、非白人患者;PBW:PFVC比值每增加1个标准差,MIMIC-IV中死亡 odds 升高1.43倍(95%CI 1.17-1.76),eICU-CRD中观察到类似结果。作者认为PBW公式会高估部分人群的伤前潮气肺容积,这种算法偏倚可能造成通气患者的死亡率差异,需进一步研究确定最佳潮气量。
要点
- 在相同PBW下,年轻、男性、白人患者的PFVC大于年老、女性、非白人患者,PBW公式会高估后者的伤前潮气肺容积。
- PBW:PFVC比值每增加1个标准差,MIMIC-IV中死亡 odds 升高1.43倍(95%CI 1.17-1.76),eICU-CRD中观察到类似结果。
- 研究纳入接受肺保护性通气、低氧血症、身高150-210 cm的患者,来自MIMIC-IV(单中心,9152例)和eICU-CRD(208家医院,12420例)。
- 作者认为这种算法偏倚可能造成通气患者的死亡率差异,需进一步研究确定最佳潮气量。
适用人群与场景
- 纳入接受肺保护性通气、低氧血症、身高150-210 cm的患者。
- MIMIC-IV队列来自美国波士顿单家学术医学中心的患者,共9152例。
- eICU-CRD队列来自美国208家医院的患者,共12420例。
研究设计与关键结果
- 研究类型为观察性、多队列、回顾性研究,比较ARMA PBW与GLI 2012参考方程计算的PFVC作为伤前肺容积代理。
- MIMIC-IV纳入9152例(女性3064例[33.5%],男性6088例[66.5%];黑人645例[7.0%],白人5885例[64.3%],其他种族2622例[28.6%];平均年龄63岁[SD 16])。
- eICU-CRD纳入12420例(女性4262例[34.3%],男性8158例[65.7%];黑人1023例[8.2%],白人10093例[81.3%],其他种族1304例[10.5%];平均年龄62岁[SD 16])。
- 在相同PBW下,年轻、男性、白人患者的PFVC大于年老、女性、非白人患者。
- PBW:PFVC比值每增加1个标准差,MIMIC-IV中死亡 odds 升高1.43倍(95%CI 1.17-1.76),eICU-CRD中观察到类似结果。
证据类型、等级与局限
- 证据类型:观察性、多队列、回顾性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,与其他人相比,使用PBW公式调整潮气量会高估年老、矮小、女性和非白人患者的伤前潮气肺容积。
- 作者认为,这种算法偏倚可能造成通气患者的死亡率差异。
- 作者认为,需进一步研究确定机械通气患者的最佳潮气量。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Lung-protective mechanical ventilation with low tidal volume (VT) decreased mortality in the ARMA trial. VT in that trial was adjusted to predicted bodyweight (PBW) as a proxy for preinjury lung volumes, an approach that is now commonly used to set target VT in patients who are mechanically ventilated. In other clinical contexts, PBW is not used to estimate lung volumes and spirometric reference equations are used instead. We aimed to compare predicted forced vital capacity (PFVC), calculated using the Global Lung Initiative 2012 spirometric reference equations, with PBW as a proxy for preinjury lung volume.
METHODS: In this observational, multicohort, retrospective study we compared ARMA PBW with PFVC estimated with the Global Lung Initiative 2012 reference equations for two cohorts: Medical Information Mart for Intensive Care-IV (MIMIC-IV), a cohort of patients from a single academic medical centre in Boston, MA, USA, and electronic Intensive Care Unit Collaborative Research Database (eICU-CRD), a cohort of patients from 208 hospitals in the USA. Patients who had lung-protective ventilation, hypoxaemia, and height in the range 150-210 cm were included. The data were collected from publicly available, deidentified datasets. We then studied the association between normalised VT (VT per PBW or VT per PFVC) and the ratio of lung volume estimates (PBW:PFVC) and mortality, driving pressure, and normalised elastance in patients receiving lung-protective ventilation with VT per PBW of 6-8 mL/kg.
FINDINGS: 9152 patients were included from MIMIC-IV (3064 [33·5%] female and 6088 [66·5%] male; 645 [7·0%] Black, 5885 [64·3%] White, and 2622 [28·6%] other race; mean age 63 years [SD 16]) and 12 420 patients were included from eICU-CRD (4262 [34·3%] female and 8158 [65·7%] male; 1023 [8·2%] Black, 10 093 [81·3%] White, and 1304 [10·5%] other race; mean age 62 years [SD 16]). Patients who were younger, male, and White had greater PFVCs than patients who were older, female, and non-White with the same PBW. A 1 SD increase in PBW:PFVC ratio was associated with 1·43-fold (95% CI 1·17-1·76) higher odds of death in MIMIC-IV and similar results were observed in the eICU-CRD cohort.
INTERPRETATION: Adjusting VT using PBW formulas leads to overestimation of preinjury tidal lung volumes in patients who are older, shorter, female, and non-White compared with other patients. This algorithmic bias could contribute to mortality disparities in patients who are ventilated. Further research is required to establish the optimal tidal volumes for patients who are mechanically ventilated.
FUNDING: National Heart, Lung, and Blood Institute.
参考来源
- Sarma A, Sullivan KM, Baugh AD, et al. Evaluating the generalisability of formulas used to set tidal volumes in mechanically ventilated patients: an observational, multicohort, retrospective study. Lancet Respir Med. 2025. PMID: 40680763. doi:10.1016/S2213-2600(25)00126-2
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。