文献速递复苏、休克与脓毒症心脑血管急症

振幅谱面积预测基础生命支持治疗院外心脏骤停中真性电击难治性室颤

Amplitude spectrum area to predict true shock-refractory ventricular fibrillation during basic life support-treated out-of-hospital cardiac arrest.
PubMed 文献 · Resuscitation · 2025-06-27
一句话结论在意大利8城市1646例可电击院外心脏骤停中,首次电击前振幅谱面积(AMSA)较低与真性电击难治性室颤相关(aOR 0.81,95%CI 0.73-0.88,p<0.0001)。

研究纳入意大利8个城市院外心脏骤停且初始心律为可电击心律的1646例患者,分析每次除颤前2秒室颤窗口的振幅谱面积(AMSA)。按指南定义(3次电击后室颤持续)判定为实用性难治性室颤者360例(22%),其中真性电击难治性室颤占18%、难治复发性室颤占82%。真性电击难治性室颤的AMSA显著低于难治复发性室颤,首次AMSA较低与真性电击难治性室颤发生相关(aOR 0.81,95%CI 0.73-0.88,p<0.0001)。作者认为早期识别不同室颤亚型可能有助于指导院外心脏骤停的高级复苏策略。

要点

  • 在1646例初始可电击心律的院外心脏骤停中,360例(22%)符合指南定义的实用性难治性室颤(3次电击后室颤持续)。
  • 360例实用性难治性室颤中,真性电击难治性室颤占18%,难治复发性室颤占82%。
  • 真性电击难治性室颤的AMSA显著低于难治复发性室颤。
  • 首次AMSA较低与真性电击难治性室颤发生相关(aOR 0.81,95%CI 0.73-0.88,p<0.0001)。
  • 作者认为早期识别不同室颤亚型可能有助于指导院外心脏骤停的高级复苏策略。

适用人群与场景

  • 意大利8个城市中由自动体外除颤器记录到心电图的院外心脏骤停患者,初始心律为可电击心律,共1646例。

诊断标准与关键阈值

  • 实用性难治性室颤:按指南定义,即3次电击后室颤持续。
  • 真性电击难治性室颤:在需要实施前3次电击的整个期间室颤持续存在。
  • 难治复发性室颤:前3次电击中任何一次电击短暂终止室颤后室颤再发。
  • 除颤成功定义为出现灌注性心律。

研究设计与关键结果

  • 研究为对意大利8个城市院外心脏骤停自动体外除颤器心电图的回顾性分析,纳入1646例初始可电击心律患者。
  • 1646例中360例(22%)符合实用性难治性室颤定义。
  • 360例实用性难治性室颤中,18%为真性电击难治性室颤,82%为难治复发性室颤。
  • 真性电击难治性室颤的AMSA显著低于难治复发性室颤。
  • 首次AMSA较低与真性电击难治性室颤发生相关(aOR 0.81,95%CI 0.73-0.88,p<0.0001)。

证据类型、等级与局限

  • 证据类型:基于自动体外除颤器心电图的观察性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为早期识别不同室颤亚型可能有助于指导院外心脏骤停的高级复苏策略。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM: Refractory ventricular fibrillation (VF) is associated with decreased survival. Guideline definition of refractory VF, i.e. a VF persisting after 3 shocks, includes cases of true shock-refractory VF or recurrent VF with transient defibrillation response. Predicting true shock-refractory VF before repeated shock failure could prioritize targeted interventions to improve out-of-hospital cardiac arrest (OHCA) outcomes. We hypothesized that amplitude spectrum area (AMSA) may predict cases of true refractory VF.

METHODS: ECGs recorded by automated external defibrillators were obtained from OHCAs in 8 cities in Italy. A 2-second VF window before each defibrillation was analyzed to calculate Amplitude Spectrum Area (AMSA). Defibrillation success was defined by occurrence of a perfusing rhythm, while refractory VF was defined as: "pragmatic-refractory" (based on guideline definition); or within this category, as "True shock-refractory", if VF continuously persisted over the period needed to deliver the first 3 shocks; or "refractory-recurrent", if VF recurred after any of the first three shocks transiently terminated VF.

RESULTS: 1646 OHCAs with shockable presenting rhythm were included, 360 (22 %) of whom met the definition of pragmatic-refractory VF. Among the 360 cases of pragmatic-refractory VF, 18 % were true shock-refractory and 82 % were refractory-recurrent VF. AMSA was significantly lower in true shock-refractory VF than in refractory-recurrent VF. A lower first AMSA was associated with occurrence of true shock-refractory VF (aOR:0.81; 95 %CI: 0.73-0.88; p < 0.0001).

CONCLUSIONS: Lower AMSA is associated with true shock-refractory VF, a subtype associated with persistent defibrillation failure and worse long-term survival. Identifying different VF subtypes early may help guide advanced resuscitation strategies in OHCA.

来源:Resuscitation,查看原文。版权归原作者所有。