指南与共识创伤与烧伤复苏、休克与脓毒症

创伤患者中局部旋转血栓弹力图推荐意见的依从性:一项回顾性队列研究

Adherence to local rotational thromboelastometry recommendations in the care of trauma patients: A retrospective cohort study.
指南 / 共识 · Transfusion · 2025-07-30
一句话结论创伤患者对基于ROTEM的局部止血治疗推荐完全依从率仅46.6%,完全依从与院内死亡率降低无显著相关(OR 0.71,95%CI 0.35-1.41)。

该回顾性队列研究纳入了2017年1月1日至2021年12月31日期间在一级创伤中心接受ROTEM检测的创伤患者,比较首次ROTEM检测后实际使用的血液制品与依据ROTEM结果应使用的血液制品,以评估对局部ROTEM最佳实践的依从性。结果显示仅46.6%(208/446)的患者完全依从ROTEM推荐。当ROTEM推荐启动某血液制品时,该制品对应的依从性更低。ROTEM异常数量越多(OR 0.11,95%CI 0.05-0.19)和损伤严重度评分越高(OR 0.96,95%CI 0.94-0.98)依从性越低。依从ROTEM与院内死亡率降低无显著相关(OR 0.71,95%CI 0.35-1.41),而ROTEM异常数量与院内死亡率相关(OR 3.07,95%CI 2.01-4.77)。作者认为量化依从性对理解ROTEM在创伤救治中的实施有价值。

要点

  • 仅46.6%(208/446)的创伤患者完全依从局部ROTEM推荐,整体依从性为中等。
  • 当ROTEM推荐启动某血液制品时,该制品对应的依从性低于不推荐启动时。
  • ROTEM异常数量越多(OR 0.11,95%CI 0.05-0.19)和损伤严重度评分越高(OR 0.96,95%CI 0.94-0.98),依从性越低。
  • 依从ROTEM与院内死亡率降低无显著相关(OR 0.71,95%CI 0.35-1.41)。
  • ROTEM异常数量与院内死亡率相关(OR 3.07,95%CI 2.01-4.77)。

适用人群与场景

  • 2017年1月1日至2021年12月31日期间在一级创伤中心接受ROTEM检测的创伤患者。

研究设计与关键结果

  • 研究类型为回顾性队列研究,纳入一级创伤中心接受ROTEM检测的创伤患者446例,其中208例(46.6%)完全依从ROTEM推荐。
  • 当ROTEM推荐启动某血液制品时,该制品对应的依从性低于不推荐启动时。
  • ROTEM异常数量越多,依从性越低(OR 0.11,95%CI 0.05-0.19);损伤严重度评分越高,依从性越低(OR 0.96,95%CI 0.94-0.98)。
  • 依从ROTEM与院内死亡率降低无显著相关(OR 0.71,95%CI 0.35-1.41)。
  • ROTEM异常数量与院内死亡率相关(OR 3.07,95%CI 2.01-4.77)。

证据类型、等级与局限

  • 证据类型:回顾性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为量化依从性对理解ROTEM在创伤救治中的实施有价值。
  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Rotational thromboelastometry (ROTEM) is a blood test that measures hemostatic parameters to guide hemostatic therapy. ROTEM outputs can be cognitively challenging to interpret, which may limit adherence in trauma care. Our objective was to assess hemostatic therapy administration adherence to local ROTEM recommendations.

STUDY DESIGN AND METHODS: We conducted a retrospective cohort study of trauma patients receiving ROTEM testing at a level 1 trauma center between January 1st 2017, and December 31st 2021. Adherence to local ROTEM best practices was determined by comparing the blood products patients received after a patient's first ROTEM test to those that should have been administered based on their ROTEM results. Multivariable logistic regression models were used to determine the association between clinical and patient covariates with ROTEM adherence and between ROTEM adherence and in-hospital mortality.

RESULTS: Only 46.6% (n = 208/446) of patients had complete adherence to ROTEM recommendations. Product-specific adherence was lower when product initiation was recommended (vs. not) by ROTEM. A greater number of ROTEM abnormalities (odds ratio [OR]: 0.11, 95% confidence interval [CI]: 0.05-0.19) and a higher injury severity score (OR: 0.96, 95% CI: 0.94-0.98) reduced adherence. Adherence to ROTEM did not reduce in-hospital mortality (OR: 0.71, 95% CI: 0.35-1.41). The number of ROTEM abnormalities was associated with in-hospital mortality (OR: 3.07, 95% CI: 2.01-4.77).

DISCUSSION: We found moderate adherence to admission ROTEM recommendations with lower adherence for more severely injured patients. The number of ROTEM abnormalities increased the odds of in-hospital mortality. Quantifying adherence is valuable for understanding ROTEM implementations in trauma care.

来源:Transfusion,查看原文。版权归原作者所有。