文献速递儿科与产科急症消化、代谢与肾脏急症

床旁超声诊断儿童髋关节积液的诊断准确性:一项多中心诊断研究

Diagnostic Accuracy of Point-of-Care Ultrasound for Hip Effusion: A Multicenter Diagnostic Study.
PubMed 文献 · Ann Emerg Med · 2025-06-07
一句话结论由经过培训的儿科急诊医师操作床旁超声诊断儿童髋关节积液具有高敏感性和特异性,但准确性在操作量高的医师中更高。

这项多中心前瞻性研究在美国和澳大利亚的5个儿科急诊科进行,纳入2019年10月至2023年10月期间因临床需要接受放射科超声评估髋关节积液的18岁及以下儿童。共161名参与者(2月龄至15岁)接受儿科急诊医师的床旁超声和放射科超声检查,以放射科超声为参考标准。整体按髋分析,床旁超声敏感性89.3%(95%CI 80.6-95.0%),特异性99.2%(95%CI 97.0-99.9%)。3名高操作量医师的敏感性98.1%、特异性97.8%,其余15名医师敏感性83.3%、特异性97.4%。结论提示经聚焦培训的医师可获得高诊断准确性。

要点

  • 按髋分析,床旁超声诊断儿童髋关节积液敏感性89.3%(95%CI 80.6-95.0%),特异性99.2%(95%CI 97.0-99.9%)。
  • 3名高操作量儿科急诊医师的床旁超声敏感性98.1%(95%CI 88.8-99.9%),特异性97.8%(95%CI 86.8-99.9%)。
  • 其余15名医师的床旁超声敏感性83.3%(95%CI 61.8-94.5%),特异性97.4%(95%CI 84.6-99.9%)。
  • 床旁超声识别77个髋关节积液,放射科超声识别82个。
  • 共161名儿童(2月龄至15岁,平均62.4±3.1月龄)参与,扫描322个髋关节,由18名认证儿科急诊医师完成。

适用人群与场景

  • 18岁及以下儿童,因临床表现需要放射科超声评估髋关节积液而就诊于儿科急诊科。

研究设计与关键结果

  • 多中心前瞻性诊断研究,在美国和澳大利亚5个儿科急诊科进行,2019年10月至2023年10月纳入161名参与者(2月龄至15岁,平均62.4±3.1月龄),共扫描322个髋关节,由18名认证儿科急诊医师操作床旁超声,以放射科超声为参考标准。
  • 3名高操作量医师纳入99/161(61.5%)的受试者,其床旁超声敏感性98.1%(95%CI 88.8-99.9%),特异性97.8%(95%CI 86.8-99.9%)。
  • 其余15名医师的床旁超声敏感性83.3%(95%CI 61.8-94.5%),特异性97.4%(95%CI 84.6-99.9%)。
  • 按髋分析,床旁超声敏感性89.3%(95%CI 80.6-95.0%),特异性99.2%(95%CI 97.0-99.9%);床旁超声识别77个髋关节积液,放射科超声识别82个。

证据类型、等级与局限

  • 证据类型:多中心前瞻性诊断研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,由经过聚焦培训的儿科急诊医师操作床旁超声诊断儿童髋关节积液具有高敏感性和特异性,在类似培训的人员中可能可行。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

STUDY OBJECTIVE: To determine the diagnostic accuracy of point-of-care ultrasound (POCUS) performed by pediatric emergency physicians for the diagnosis of hip effusion.

METHODS: This multicenter, prospective study was conducted in 5 pediatric emergency departments (PEDs) in the United States and Australia from October 2019 to October 2023. Children aged 18 years and younger who presented to the PED with clinical presentation requiring radiology-performed ultrasound (RADUS) for evaluation of a hip effusion were eligible. Participants received POCUS by pediatric emergency physicians credentialed to perform hip ultrasound and RADUS of both hips. Physicians categorized their POCUS findings as "yes" or "no" for the presence of hip effusion based on standard measurement definition. The primary outcome was the diagnostic accuracy of POCUS using RADUS as the reference standard in diagnosing hip effusion.

RESULTS: A total of 161 participants, aged 2 months to 15 years, were enrolled (mean age 62.4 ± 3.1 months), with 322 hips scanned. A total of 18 credentialed pediatric emergency physicians enrolled the participants, with 3 physicians accounting for enrollment of 99/161 (61.5%) of the subjects. For the 3 high-volume pediatric emergency physicians, POCUS had a sensitivity of 98.1% (95% confidence interval [CI] 88.8% to 99.9%) and specificity of 97.8% (95% CI 86.8% to 99.9%). Among the remaining 15 physicians, POCUS had a sensitivity of 83.3% (95% CI 61.8% to 94.5%) and specificity of 97.4% (95% CI 84.6% to 99.9%). POCUS identified 77 hip effusions and RADUS identified 82 hip effusions. In per hip analysis, POCUS had a sensitivity of 89.3% (95% CI 80.6 to 95.0%) and specificity of 99.2% (95% CI 97.0 to 99.9%).

CONCLUSION: POCUS had high sensitivity and specificity for diagnosing hip effusion in children when performed by a small group of pediatric emergency physicians with focused training, suggesting that accurate diagnosis may be feasible in similarly trained individuals.

来源:Ann Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Jones RM, Malia L, Snelling PJ, et al. Diagnostic Accuracy of Point-of-Care Ultrasound for Hip Effusion: A Multicenter Diagnostic Study. Ann Emerg Med. 2025. PMID: 40481828. doi:10.1016/j.annemergmed.2025.04.033

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。