氧疗目标对院外心脏骤停后肺血流动力学的影响:BOX心脏骤停试验的子研究
该研究为BOX试验预设的两中心、前瞻性、双盲子研究,纳入730例院外心脏骤停后昏迷复苏患者,随机分为限制性氧疗目标(PaO2 9-10 kPa)或宽松氧疗目标(PaO2 13-14 kPa),通过肺动脉导管和系列血气分析监测初始48小时血流动力学。主要终点为48小时内肺血管阻力(PVR)组间差异,结果显示宽松组与限制组PVR均值差异为0.05 WU(95%CI -0.09至0.18,p=0.50),无统计学显著差异;平均肺动脉压(mPAP)、肺动脉搏动指数(PAPi)和右心房压组间亦无显著差异(p>0.05)。与mPAP<20 mmHg相比,肺动脉高压(mPAP>30 mmHg)与死亡风险升高相关(OR=4.2;95%CI 2.0-9.2,p<0.001)。结论认为肺动脉高压是院外心脏骤停后昏迷复苏患者死亡的独立危险因素,但限制性氧疗策略不增加PVR或恶化右心室功能。
要点
- 院外心脏骤停后昏迷患者中,限制性氧疗目标(PaO2 9-10 kPa)与宽松氧疗目标(PaO2 13-14 kPa)相比,48小时内肺血管阻力无显著差异(均值差0.05 WU,95%CI -0.09至0.18,p=0.50)。
- 平均肺动脉压(mPAP)、肺动脉搏动指数(PAPi)和右心房压在两氧疗组间均无显著差异(p>0.05)。
- 与mPAP<20 mmHg相比,肺动脉高压(mPAP>30 mmHg)与一年死亡风险升高独立相关(OR=4.2;95%CI 2.0-9.2,p<0.001)。
- 入院时中位PVR为2.4 WU(95%CI 1.7-3.4),mPAP为25 mmHg(95%CI 21-30),PAPi为1.3(95%CI 0.8-1.8)。
- 在院外心脏骤停后复苏后重症监护中,采用限制性氧疗目标(PaO2 9-10 kPa)未观察到肺血管阻力升高或右心室功能恶化。
适用人群与场景
- 院外心脏骤停后昏迷复苏患者,纳入BOX试验随机分组且具有右心导管检查的730例(占789例随机患者的93%)。
- 研究场景为复苏后重症监护,初始48小时进行有创血流动力学评估。
诊断标准与关键阈值
- 限制性氧疗目标:动脉血氧分压(PaO2)9-10 kPa。
- 宽松氧疗目标:动脉血氧分压(PaO2)13-14 kPa。
- 肺动脉高压定义:平均肺动脉压(mPAP)>30 mmHg(对照参考mPAP<20 mmHg)。
处置流程与药物剂量
- 随机分配至限制性氧疗目标(PaO2 9-10 kPa)或宽松氧疗目标(PaO2 13-14 kPa)。
- 通过肺动脉导管进行有创血流动力学监测,并行动脉血气系列分析,持续初始48小时。
红旗征与不能漏的情况
- 肺动脉高压(mPAP>30 mmHg)与一年死亡风险升高独立相关(OR=4.2;95%CI 2.0-9.2,p<0.001),需识别并关注。
研究设计与关键结果
- 研究类型:预设的两中心、前瞻性、双盲子研究,来自BOX试验。
- 样本量:789例随机患者中730例(93%)具有右心导管检查并纳入本子研究。
- 人群:院外心脏骤停后昏迷复苏患者。
- 干预与对照:限制性氧疗目标(PaO2 9-10 kPa)vs 宽松氧疗目标(PaO2 13-14 kPa)。
- 主要终点:48小时内肺血管阻力(PVR)组间差异,采用线性混合模型重复测量;宽松组与限制组平均PVR均值差0.05 WU(95%CI -0.09至0.18,p=0.50),无显著差异。
- 关键次要终点:mPAP、PAPi、右心房压组间均无显著差异(p>0.05);入院时中位PVR 2.4 WU(95%CI 1.7-3.4),mPAP 25 mmHg(95%CI 21-30),PAPi 1.3(95%CI 0.8-1.8)。
- 肺动脉高压与结局:与mPAP<20 mmHg相比,肺动脉高压(mPAP>30 mmHg)与死亡风险升高相关(OR=4.2;95%CI 2.0-9.2,p<0.001);校正后一年死亡比值比在宽mPAP范围内呈渐进线性增加。
证据类型、等级与局限
- 证据类型:前瞻性、双盲、随机对照试验的子研究(预设分析)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在院外心脏骤停后昏迷复苏患者的复苏后重症监护中,采用限制性氧疗目标(PaO2 9-10 kPa)未观察到肺血管阻力升高或右心室功能恶化,与宽松氧疗目标(PaO2 13-14 kPa)相比肺血流动力学无显著差异。
- 肺动脉高压(mPAP>30 mmHg)是院外心脏骤停后昏迷复苏患者死亡的独立危险因素(OR=4.2;95%CI 2.0-9.2),提示应关注此类患者的肺动脉压评估。
指南或共识出处
- BOXA心脏骤停试验(Blood pressure and oxygenation targets after out-of-hospital cardiac arrest, BOX)子研究,发表于Resuscitation。
提炼说明
- 本条依据论文摘要整理;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
AIM: Hypoxia may induce harmful effects in critically ill patients, potentially including pulmonary vasoconstriction. We aimed to assess the impact of two different oxygen targets on pulmonary hemodynamics in comatose patients resuscitated from out-of-hospital cardiac arrest (OHCA). Furthermore, we assessed the prevalence of pulmonary hypertension in patients with OHCA and its association with outcome.
METHODS: Predefined, two-centre, prospective, double-blinded sub-study of the "Blood pressure and oxygenation targets after out-of-hospital cardiac arrest (BOX)"-trial. Patients were randomized to a restrictive oxygen target of a partial pressure of arterial oxygen (PaO2) of 9-10 kPa or a liberal oxygen target of a PaO2 of 13-14 kPa. Invasive hemodynamic assessment was recorded from pulmonary artery catheterization and serial blood-gas analyses for an initial 48 h. The primary endpoint was the difference in pulmonary vascular resistance (PVR) within 48 h between oxygen groups using linear mixed models for repeated measures.
RESULTS: Among 789 randomized patients, 730 (93%), who had right heart catheterization, were included in this sub-study. At admission, the median PVR, mean pulmonary artery pressure (mPAP), and pulmonary artery pulsatility index (PAPi) were 2.4 wood unit (WU) (95% CI, 1.7-3.4), 25 mmHg (95% CI, 21-30) and 1.3 (95% CI, 0.8-1.8), respectively. The average PVR in the liberal oxygen group was comparable to that of the restrictive group (mean difference 0.05 WU, 95% CI, -0.09 to 0.18, p = 0.50). mPAP, PAPi, and right atrial pressure did not differ between groups (p > 0.05). The adjusted odds ratio for one-year mortality increased progressively and linearly over a wide mPAP range. Compared with mPAP < 20 mmHg, pulmonary hypertension (mPAP > 30 mmHg) was associated with an increased risk of mortality (OR = 4.2; 95% CI, 2.0-9.2, p < 0.001).
CONCLUSION: Pulmonary hypertension is an independent risk factor for mortality in comatose resuscitated patients after OHCA. However, a restrictive oxygen strategy aiming at a PaO2 of 9-10 kPa during post-resuscitation critical care was not associated with a higher PVR or deterioration of right ventricular function compared to a liberal oxygen strategy.
参考来源
- Mølstrøm S, Beske RP, Grand J, et al. Effect of oxygen targets on pulmonary hemodynamics after out-of-hospital cardiac arrest - A sub-study of the BOX cardiac arrest trial. Resuscitation. 2025. PMID: 40517936. doi:10.1016/j.resuscitation.2025.110680
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。