文献速递复苏、休克与脓毒症心脑血管急症

心肺复苏中脉冲波脑组织氧饱和度与呼气末二氧化碳的相关性

Correlation between pulse-wave cerebral tissue oxygen saturation and end-tidal carbon dioxide during cardiopulmonary resuscitation.
PubMed 文献 · Am J Emerg Med · 2025-06-22
一句话结论心脏骤停患者CPR期间,脉冲波脑组织氧饱和度(SnO2)与呼气末二氧化碳(ETCO2)呈正相关,SnO2可更快速测量,作者认为其有助于在插管前或无法插管时评估CPR质量。

本研究为回顾性观察研究,纳入到达山形大学医院急诊部的28例心脏骤停患者,探讨CPR期间脑组织氧饱和度与ETCO2的相关性,以SnO2和TOI作为脑组织氧饱和度标志物。插管后3分钟时,SnO2与ETCO2的相关系数为0.586(p=0.004),TOI为0.555(p=0.003);平均SnO2与平均ETCO2的相关系数为0.630(p=0.002),平均TOI为0.643(p<0.001)。作者结论认为SnO2和TOI与ETCO2在平均值及插管后3分钟记录值上均呈正相关,SnO2比ETCO2测量更快速,可用于插管前或无法插管时评估CPR质量。

要点

  • 心脏骤停CPR期间,插管后3分钟SnO2与ETCO2相关系数0.586(p=0.004),TOI为0.555(p=0.003)。
  • 平均SnO2与平均ETCO2相关系数0.630(p=0.002),平均TOI与平均ETCO2相关系数0.643(p<0.001)。
  • SnO2比ETCO2测量更快速,作者认为可用于插管前或无法插管时评估CPR质量。
  • 研究为回顾性观察研究,纳入28例到达急诊部的心脏骤停患者。

适用人群与场景

  • 到达山形大学医院急诊部的心脏骤停患者,共28例。

研究设计与关键结果

  • 研究类型:回顾性观察研究,单中心(山形大学医院急诊部),样本量28例心脏骤停患者。
  • 干预与对照:无干预分组,测量CPR期间SnO2、TOI与ETCO2并分析相关性。
  • 主要终点结果:插管后3分钟SnO2与ETCO2相关系数0.586(p=0.004),TOI与ETCO2相关系数0.555(p=0.003)。
  • 关键次要终点:平均SnO2与平均ETCO2相关系数0.630(p=0.002),平均TOI与平均ETCO2相关系数0.643(p<0.001)。

证据类型、等级与局限

  • 证据类型:回顾性观察研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为SnO2可更快速测量,有助于在插管前或无法插管的情况下评估CPR质量。
  • 本研究为回顾性观察研究,SnO2与ETCO2的相关性结果需结合原文结论理解,原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: There is mounting evidence showing that physiological monitoring of cardiopulmonary resuscitation (CPR) quality is important for achieving high-quality CPR. Cerebral tissue oxygen saturation and end-tidal carbon dioxide (ETCO2) are expected to become useful indicators for CPR quality. To reveal whether pulse-wave cerebral tissue oxygen saturation (SnO2) could be used as an indicator of CPR quality, we investigated the correlation between SnO2 and ETCO2 during CPR.

METHODS: We performed this retrospective observational study to investigate the correlation between cerebral tissue oxygen saturation and ETCO2 during CPR in patients in cardiac arrest who arrived at the emergency division of Yamagata University Hospital. SnO2 and tissue oxygenation index (TOI) were measured as markers of cerebral tissue oxygen saturation.

RESULTS: Twenty-eight patients were included in this study. The correlation coefficients between cerebral tissue oxygen saturation and ETCO2 at 3 min after intubation were 0.586 for SnO2 (p = 0.004) and 0.555 for TOI (p = 0.003). The correlation coefficients between cerebral tissue oxygen saturation and mean ETCO2 were 0.630 for mean SnO2 (p = 0.002) and 0.643 for mean TOI (p < 0.001).

CONCLUSIONS: SnO2 and TOI were positively correlated with ETCO2 during CPR in terms of the mean values and the values recorded at 3 min after intubation. SnO2 can be measured more rapidly than ETCO2, making it useful for assessing CPR quality before intubation or in situations where intubation is not feasible.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Sakaguchi K, Saito S, Takada M, et al. Correlation between pulse-wave cerebral tissue oxygen saturation and end-tidal carbon dioxide during cardiopulmonary resuscitation. Am J Emerg Med. 2025. PMID: 40570488. doi:10.1016/j.ajem.2025.06.051

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。