文献速递重症综合管理与镇静镇痛呼吸衰竭与机械通气

高流量氧疗在脑死亡诊断呼吸暂停试验中的可行性

Feasibility of High-Flow Oxygen Therapy in Apnea Testing for Brain Death Diagnosis.
PubMed 文献 · Crit Care Med · 2025-05-19
一句话结论在临床脑死亡患者中,经气管插管给予高流量氧(50 L/min、FiO2 1.0)进行呼吸暂停试验可行且安全,10分钟时PaCO2达71.3±6.0 mm Hg,且氧合维持稳定。

这项前瞻性、干预性、单中心研究在法国奥尔良大学医院ICU纳入15例符合临床脑死亡标准、需行呼吸暂停试验的成年患者,每例先后接受两次各持续10分钟的呼吸暂停试验:第一次为经气管插管T管给氧8 L/min(标准试验),第二次为经气管插管专用装置给予高流量氧50 L/min、FiO2 1.0。两种方法全部患者试验结束时PaCO2均>60 mm Hg;10分钟时T管组PaCO2为69.1±5.9 mm Hg,高流量氧组为71.3±6.0 mm Hg。T管试验期间PaO2从404±115 mm Hg显著降至215±118 mm Hg,而高流量氧试验期间PaO2从342±114 mm Hg至308±92 mm Hg保持稳定。作者认为经气管插管高流量氧是呼吸暂停试验可行且安全的方法,在标准试验已确认脑死亡的患者中可获得一致的诊断结果并维持更好的氧合,但需进一步研究尤其是随机试验证实其获益。

要点

  • 15例临床脑死亡成年患者先后接受两次10分钟呼吸暂停试验:T管8 L/min给氧与经气管插管高流量氧50 L/min、FiO2 1.0。
  • 两种方法全部患者试验结束时PaCO2均>60 mm Hg;10分钟时T管组PaCO2 69.1±5.9 mm Hg,高流量氧组71.3±6.0 mm Hg。
  • T管试验期间PaO2从404±115降至215±118 mm Hg,高流量氧试验期间PaO2从342±114至308±92 mm Hg保持稳定。
  • 作者认为经气管插管高流量氧是呼吸暂停试验可行且安全的方法,在标准试验已确认脑死亡的患者中可获得一致诊断结果并维持更好氧合。
  • 作者指出需进一步研究尤其是随机试验证实高流量氧在呼吸暂停试验中的获益。

适用人群与场景

  • 法国奥尔良大学医院ICU收治的符合临床脑死亡标准、需行呼吸暂停试验的成年患者。

处置流程与药物剂量

  • 第一次呼吸暂停试验(标准试验):经气管插管连接T管给氧8 L/min,不使用呼气末正压阀,持续10分钟。
  • 第二次呼吸暂停试验:经气管插管连接专用装置给予高流量氧50 L/min、FiO2 1.0,持续10分钟。
  • 两次试验期间每2分钟测量一次动脉血气。

研究设计与关键结果

  • 研究类型:前瞻性、干预性、单中心研究;地点为法国奥尔良大学医院ICU;样本量15例成年患者。
  • 干预:每例患者按同一顺序先后接受两次各10分钟的呼吸暂停试验,第一次为T管给氧8 L/min(标准试验),第二次为经气管插管高流量氧50 L/min、FiO2 1.0。
  • 主要终点:所有患者在两种呼吸暂停试验结束时均达到PaCO2>60 mm Hg;10分钟时PaCO2在T管组为69.1±5.9 mm Hg,在高流量氧组为71.3±6.0 mm Hg。
  • 氧合:T管试验期间PaO2从404±115 mm Hg显著降至215±118 mm Hg;高流量氧试验期间PaO2从342±114 mm Hg至308±92 mm Hg保持稳定。

证据类型、等级与局限

  • 证据类型:前瞻性、干预性、单中心研究。
  • 局限:原文未报告局限性;作者指出需进一步研究,尤其是随机试验,以证实高流量氧在呼吸暂停试验中的获益。

对床旁实践的改变

  • 作者认为,经气管插管高流量氧是呼吸暂停试验可行且安全的方法;在标准呼吸暂停试验已确认脑死亡的患者中,高流量氧可获得一致的诊断结果并维持更好的氧合。
  • 作者指出需进一步研究尤其是随机试验证实高流量氧在呼吸暂停试验中的获益。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to assess the feasibility and safety of use of high-flow oxygen (HFO) through the endotracheal tube for apnea testing during brain death evaluation.

DESIGN: Prospective, interventional, single-center study.

SETTING: ICUs at the Orléans University Hospital, France.

PATIENTS: All adult patients meeting the criteria for clinical brain death and requiring an apnea test were eligible.

INTERVENTIONS: Fifteen patients underwent two successive apnea tests in the same order, each lasting 10 minutes: The first apnea test used 8 L/min of oxygen via a T-piece without a positive end-expiratory pressure valve connected to the endotracheal tube (standard test). The second apnea test used HFO at 50 L/min and F io 2 of 1.0 through a specialized device connected to the endotracheal tube. Arterial blood gases were measured every 2 minutes during both apnea tests. The primary objective was to investigate the feasibility and safety of use of HFO through the endotracheal tube for apnea testing compared with use of a T-piece in patients whose clinical examination was consistent with brain death and required an apnea test.

MEASUREMENTS AND MAIN RESULTS: All patients reached Pa co 2 greater than 60 mm Hg by the end of both apnea tests. At 10 minutes, Pa co 2 was 69.1 ± 5.9 mm Hg with the T-piece and 71.3 ± 6.0 mm Hg with HFO. Pa o 2 decreased significantly during the T-piece apnea test (from 404 ± 115 to 215 ± 118 mm Hg) but remained stable with HFO apnea test (from 342 ± 114 to 308 ± 92 mm Hg).

CONCLUSIONS: HFO through the endotracheal tube is feasible and safe method for apnea testing. In patients with confirmed brain death via the standard apnea test, HFO yielded consistent diagnostic results while maintaining better oxygenation. Further research, particularly randomized trials, is needed to confirm the benefits of HFO in apnea testing.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Barrier D, Vanacker L, Muller G, et al. Feasibility of High-Flow Oxygen Therapy in Apnea Testing for Brain Death Diagnosis. Crit Care Med. 2025. PMID: 40387463. doi:10.1097/CCM.0000000000006717

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。