文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

严重呼吸道传染病所致急性呼吸窘迫综合征:维持人工气道密闭的临床意义与解决方案

[Acute respiratory distress syndrome caused by severe respiratory infectious diseases: clinical significance and solution of maintaining artificial airway closure].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2025-01-01
一句话结论严重呼吸道传染病所致ARDS机械通气时,短暂断开人工气道与呼吸机管路可致气溶胶外溢并加重呼吸机相关肺损伤,目前缺乏气道管路临时密闭的明确指南。

本文综述严重呼吸道传染病(SARS、MERS、甲型H1N1流感及新型冠状病毒感染)所致急性呼吸窘迫综合征(ARDS)的临床救治中,人工气道与呼吸机管路短暂断开连接导致气溶胶外溢、污染环境、增加包括医务人员在内的院内感染风险,同时干扰肺保护性通气策略实施并加重呼吸机诱导肺损伤(VILI)。研究表明大量医务人员发生院内感染,尤其是参与气管插管、拔管等气道相关操作者。除加强个人防护外,保障医务人员免受气溶胶污染、降低气道管理相关风险至关重要。目前关于气道管路与呼吸机系统临时密闭的研究较少,缺乏明确指导,本文汇总相关领域研究现状以提供参考。

要点

  • 气溶胶携带病原体是多种严重呼吸道传染病的主要传播途径,可导致感染者严重呼吸衰竭甚至ARDS。
  • 机械通气是ARDS的主要治疗,小潮气量、适当水平呼气末正压的肺保护性通气策略可有效降低VILI发生率。
  • 临床治疗中有时需短暂断开人工气道与呼吸机管路的连接,可致呼吸道残留气溶胶外溢污染环境,增加包括医务人员在内的院内感染风险。
  • 断开连接还干扰肺保护性通气策略实施并加重VILI。
  • 大量医务人员发生院内感染,尤其是参与气管插管、拔管等气道相关操作者;除加强个人防护外,保障医务人员免受气溶胶污染至关重要。

适用人群与场景

  • 感染严重呼吸道传染病(如SARS、MERS、甲型H1N1流感及新型冠状病毒感染)并发生严重呼吸衰竭甚至ARDS、接受机械通气的患者。

处置流程与药物剂量

  • 机械通气是ARDS的主要治疗,采用小潮气量、适当水平呼气末正压的肺保护性通气策略以有效降低VILI发生率。
  • 除增强个人防护措施外,保障医务人员免受气溶胶污染并尽量减少气道管理相关风险至关重要。

红旗征与不能漏的情况

  • 临床治疗中有时需短暂断开人工气道与呼吸机管路的连接,可致呼吸道残留气溶胶外溢污染周围环境,增加包括医务人员在内的院内感染风险,并干扰肺保护性通气策略实施、加重VILI。

研究设计与关键结果

  • 本文为综述,汇总严重呼吸道传染病所致ARDS救治中维持人工气道密闭的相关研究现状。
  • 气溶胶携带病原体是多种严重呼吸道传染病的主要传播途径,可导致感染者严重呼吸衰竭甚至ARDS。
  • 机械通气是ARDS的主要治疗,小潮气量、适当水平呼气末正压的肺保护性通气策略可有效降低VILI发生率。
  • 短暂断开人工气道与呼吸机管路连接可致残留气溶胶外溢污染环境、增加院内感染风险,并干扰肺保护性通气策略、加重VILI。
  • 研究表明大量医务人员发生院内感染,尤其是参与气管插管、拔管等气道相关操作者。
  • 目前关于气道管路与呼吸机系统临时密闭的研究较少,缺乏明确指导。

证据类型、等级与局限

  • 证据类型:综述。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,除增强个人防护措施外,保障医务人员免受气溶胶污染并尽量减少气道管理相关风险至关重要。
  • 目前关于气道管路与呼吸机系统临时密闭的研究较少且缺乏明确指导,本文汇总相关领域研究现状以提供参考。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Since the beginning of the 21st century, the severe respiratory infectious diseases worldwide [such as severe acute respiratory syndrome (SARS), Middle East respiratory syndrome (MERS), influenza A H1N1 and novel coronavirus infection have attracted wide attention from all walks of life due to their superior pathogenicity and transmissibility. Aerosols-carrying pathogens are the main transmission route of many severe respiratory infectious diseases, which can lead to severe respiratory failure and even acute respiratory distress syndrome (ARDS) in infected individuals. Mechanical ventilation is the primary treatment for ARDS, and the small tidal volume, appropriate level of positive end-expiratory pressure based lung protective ventilation strategy can effectively reduce the incidence of ventilator-induced lung injury (VILI). However, in the process of clinical treatment, it is sometimes necessary to briefly disconnect the connection between the artificial airway and the ventilator circuit, which will not only cause the residual aerosol in the respiratory system to spill out and pollute the surrounding environment, increase the risk of nosocomial infection including medical staff, but also interfere with the implementation of lung protective ventilation strategy and aggravate ventilator-induced lung injury. In addition, studies have shown that a lot of medical staff have nosocomial infections, especially staff involved in tracheal intubation, extubation and other airway related operations. In addition to enhancing personal protective measures, it is crucial to safeguard healthcare workers from aerosol contamination and minimize associated risks during airway management. At present, there are few researches on the temporary sealing of airway lines and ventilator system, and there is a lack of clear guidance. This review summarizes the research status in related fields to provide a reference for corresponding solutions and programs.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Zhang J, Li Y, Li H, et al. [Acute respiratory distress syndrome caused by severe respiratory infectious diseases: clinical significance and solution of maintaining artificial airway closure]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2025. PMID: 40201990. doi:10.3760/cma.j.cn121430-20240506-00404

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。