文献速递呼吸衰竭与机械通气心脑血管急症

使用年龄校正D-二聚体切点与D-二聚体单位检测评估疑似肺栓塞患者结局

Evaluating outcomes of patients with suspected pulmonary embolism using an age-adjusted cutoff with a D-dimer unit-based assay.
PubMed 文献 · Am J Emerg Med · 2025-04-12
一句话结论在基于D-二聚体单位(DDU)的检测中,年龄校正D-二聚体切点较常规切点提高特异性(16.6% vs 7.3%),敏感性相近(96.1% vs 97.4%),差异无统计学意义。

本研究纳入1831例急诊就诊并完成D-二聚体检测后行CT肺动脉造影(CTA)的疑似肺栓塞患者,实验室使用HemosIL D-Dimer HS试剂,以DDU(ng/mL)报告D-二聚体值。研究者按年龄(岁)×5 ng/mL公式回顾性校正D-二聚体水平,形成年龄校正切点组,与常规切点230 ng/mL比较诊断效能。结果显示年龄校正切点敏感性96.1%(95%CI 93.5-98.6%)、特异性16.6%(95%CI 14.8-18.4%);常规切点敏感性97.4%(95%CI 95.3-99.4%)、特异性7.3%(95%CI 6.0-8.6%)。作者结论认为,在DDU检测中年龄校正切点特异性更高而敏感性相近,差异无统计学意义。

要点

  • 在DDU报告D-二聚体的检测中,年龄校正切点(年龄×5 ng/mL)特异性16.6%,高于常规切点230 ng/mL的7.3%。
  • 年龄校正切点敏感性96.1%,常规切点97.4%,两者差异无统计学意义。
  • 年龄校正切点阴性预测值96.7%(95%CI 94.6-98.8%),常规切点95.1%(95%CI 91.3-98.9%)。
  • 年龄校正切点阳性预测值14.1%(95%CI 12.3-15.8%),常规切点13%(95%CI 11.4-14.6%)。
  • 本研究为回顾性调整D-二聚体水平形成比较组,评估疑似肺栓塞急诊患者的诊断效能。

适用人群与场景

  • 就诊于急诊科并完成诊断检查的疑似肺栓塞患者,检查包括D-二聚体检测后行CT肺动脉造影(CTA)。
  • 共纳入1831例患者。

诊断标准与关键阈值

  • 常规D-二聚体切点:230 ng/mL(DDU)。
  • 年龄校正D-二聚体切点:年龄(岁)×5 ng/mL(DDU)。

研究设计与关键结果

  • 研究类型:回顾性研究,纳入1831例急诊疑似肺栓塞患者,使用HemosIL D-Dimer HS试剂以DDU(ng/mL)报告D-二聚体值。
  • 常规切点230 ng/mL:敏感性97.4%(95%CI 95.3-99.4%),特异性7.3%(95%CI 6.0-8.6%),阳性预测值13%(95%CI 11.4-14.6%),阴性预测值95.1%(95%CI 91.3-98.9%)。
  • 年龄校正切点:敏感性96.1%(95%CI 93.5-98.6%),特异性16.6%(95%CI 14.8-18.4%),阳性预测值14.1%(95%CI 12.3-15.8%),阴性预测值96.7%(95%CI 94.6-98.8%)。
  • 年龄校正切点特异性高于常规切点,敏感性相近,差异无统计学意义。

证据类型、等级与局限

  • 证据类型:回顾性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在采用DDU报告D-二聚体的实验室中,年龄校正切点(年龄×5 ng/mL)较常规切点230 ng/mL提高特异性(16.6% vs 7.3%),敏感性相近(96.1% vs 97.4%),差异无统计学意义。
  • 本研究为回顾性调整D-二聚体水平形成比较组,作者结论认为年龄校正切点特异性更高而敏感性相近,差异无统计学意义。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Studies have suggested that an age-adjusted D-dimer (AADD) could improve specificity while maintaining sensitivity for the diagnosis of pulmonary embolism (PE). Most laboratories and published data report D-dimer in fibrinogen equivalent units, but some laboratory assays report using D-dimer units (DDU). However, only two small studies have examined AADD with a DDU-based assay. Our study aims to assess the sensitivity and specificity of AADD cutoffs, compared to the conventional cutoffs, in a large cohort of patients who underwent D-dimer testing using a DDU-based assay, for suspected PE.

METHODS: We included 1831 patients who presented to the emergency department and underwent a diagnostic workup that included a D-dimer test followed by computed tomography pulmonary angiography (CTA). The laboratory utilized the HemosIL D-Dimer HS reagent, reporting D-dimer values in DDU (ng/mL). We retrospectively adjusted D-dimer levels for patients using the formula: age (years) x 5 ng/mL. This adjustment created a comparison group to evaluate the test characteristics of the AADD cutoff compared to the conventional cutoff.

RESULTS: The conventional D-dimer cutoff of 230 ng/mL had a sensitivity of 97.4 % (95 % Confidence Interval [CI]: 95.3-99.4 %), specificity of 7.3 % (CI: 6.0-8.6 %), positive predictive value (PPV) of 13 % (CI: 11.4-14.6 %), and negative predictive value (NPV) of 95.1 % (CI: 91.3-98.9 %). The AADD cutoff had a sensitivity of 96.1 % (CI: 93.5-98.6 %), specificity of 16.6 % (CI: 14.8-18.4 %), PPV of 14.1 % (CI: 12.3-15.8 %), and NPV of 96.7 % (CI: 94.6-98.8 %).

CONCLUSION: In this study using a DDU-based assay, the specificity of the AADD cutoff was greater while the sensitivity was similar to that of the unadjusted cutoff, with no statistically significant difference observed.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Novak D, Quinn E, Butt M, et al. Evaluating outcomes of patients with suspected pulmonary embolism using an age-adjusted cutoff with a D-dimer unit-based assay. Am J Emerg Med. 2025. PMID: 40262289. doi:10.1016/j.ajem.2025.04.026

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。