低与高呼气末正压无创通气治疗低氧性呼吸衰竭:多中心随机对照试验
该多中心、开放标签随机对照试验纳入中国7个ICU的380例接受无创通气的低氧血症患者,1:1随机分为低PEEP组(5 cmH2O)和高PEEP组(10-15 cmH2O)。主要终点无创通气失败(插管、死亡或治疗中止)在高PEEP组为32%(61/190),低PEEP组为43%(82/190),绝对差异11.1%(95%CI 1.3-20.5%,p=0.034)。随机化后72小时内,低PEEP组PaO2/FiO2更低(平均差-31 mmHg,95%CI -38至-24)、潮气量更高(0.8 mL/kg预测体重,95%CI 0.5-1.1),但需要更高支持压力(平均差2.9 cmH2O,95%CI 2.7-3.1)。不良事件两组无差异。作者认为高PEEP可能降低治疗失败,但获益可能部分受低PEEP组更高潮气量混杂,且研究统计效力不足,解读需谨慎。
要点
- 高PEEP组(10-15 cmH2O)无创通气失败率32%(61/190),低PEEP组(5 cmH2O)为43%(82/190),绝对差异11.1%(95%CI 1.3-20.5%,p=0.034)。
- 随机化后72小时内,低PEEP组PaO2/FiO2较低PEEP组更低(平均差-31 mmHg,95%CI -38至-24),潮气量更高(0.8 mL/kg预测体重,95%CI 0.5-1.1)。
- 低PEEP组需要更高的支持压力(平均差2.9 cmH2O,95%CI 2.7-3.1),不良事件两组无差异。
- 作者认为高PEEP可能降低治疗失败,但获益可能部分受低PEEP组更高潮气量混杂,且研究统计效力不足,解读需谨慎。
适用人群与场景
- 中国7个ICU中接受无创通气(经口鼻面罩或鼻面罩)的低氧血症患者。
处置流程与药物剂量
- 低PEEP组:PEEP 5 cmH2O,IPAP 10-20 cmH2O。
- 高PEEP组:PEEP 10-15 cmH2O,IPAP 15-20 cmH2O。
研究设计与关键结果
- 多中心、开放标签、随机对照试验,中国7个ICU,2022年1月11日至2024年8月31日纳入380例(每组190例),意向性治疗分析。
- 主要终点无创通气失败(插管、死亡或治疗中止):低PEEP组43%(82/190) vs 高PEEP组32%(61/190),绝对差异11.1%(95%CI 1.3-20.5%,p=0.034)。
- 随机化后72小时内,低PEEP组PaO2/FiO2较低PEEP组更低(平均差-31 mmHg,95%CI -38至-24),潮气量更高(0.8 mL/kg预测体重,95%CI 0.5-1.1),需要更高支持压力(平均差2.9 cmH2O,95%CI 2.7-3.1)。
- 不良事件两组无差异。
证据类型、等级与局限
- 证据类型:多中心、开放标签、随机对照试验。
- 局限:作者指出获益可能部分受低PEEP组更高潮气量混杂;研究统计效力不足,无法检测显著差异;解读需谨慎。
对床旁实践的改变
- 作者认为高PEEP可能降低急性低氧性呼吸衰竭患者的无创通气治疗失败率,但解读需谨慎,因获益可能部分受低PEEP组更高潮气量混杂且研究统计效力不足。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
PURPOSE: To assess whether high positive end expiratory pressure (PEEP) reduces the rate of noninvasive ventilation (NIV) failure in hypoxemic patients.
METHODS: This multicenter, open-label, randomized controlled trial was conducted across seven ICUs in China. Hypoxemic patients who received NIV via oronasal or nasal mask were randomized 1:1 to either low PEEP (5 cmH2O) or high PEEP (10-15 cmH2O) groups, with inspiratory positive airway pressure (IPAP) set at 10-20 cmH2O and 15-20 cmH2O, respectively. The primary outcome was NIV failure, defined as intubation, death, or therapy withdrawal (refusal of intubation despite need).
RESULTS: Between January 11, 2022, and August 31, 2024, 380 patients (190 per group) were enrolled in an intention-to-treat analysis. NIV failure occurred in 43% (82/190) of the low PEEP group and 32% (61/190) of the high PEEP group (absolute difference: 11.1%, 95% CI 1.3-20.5%, p = 0.034). Within 72 h post-randomization, the low PEEP group exhibited lower PaO2/FiO2 ratios (mean difference: - 31 mmHg, 95% CI - 38 to - 24) and higher tidal volume (0.8 mL/kg predicted body weight, 95% CI 0.5-1.1) than the high PEEP group. However, the low PEEP group required higher support pressure (mean difference: 2.9 cmH2O, 95% CI 2.7-3.1). Adverse events did not differ between the groups.
CONCLUSIONS: High PEEP during NIV may reduce treatment failure in patients with acute hypoxemic respiratory failure, although this benefit may be partially confounded by higher tidal volume observed in the low PEEP group. However, the interpretation of this effect should be carried out with caution as the study has insufficient statistical power to detect a significant difference.
参考来源
- Duan J, Liu X, Shu W, et al. Low versus high positive end expiratory pressure in noninvasive ventilation for hypoxemic respiratory failure: a multicenter randomized controlled trial. Intensive Care Med. 2025. PMID: 40304742. doi:10.1007/s00134-025-07902-4