视神经鞘直径超声诊断非创伤性神经重症患者颅内压升高:诊断准确性系统评价与Meta分析
该系统评价与Meta分析检索PubMed、Embase和Cochrane Library,纳入18项观察性研究、共1484例成人非创伤性神经重症患者,评估超声测量视神经鞘直径(ONSD)诊断颅内压升高(IICP)的准确性,参照标准为有创或无创方法。IICP病因包括中枢神经系统感染、颅内出血、急性缺血性卒中、动脉瘤性蛛网膜下腔出血、特发性颅内高压和缺氧缺血性脑损伤。汇总诊断比值比44.7(95%CI 22.5-80.1),敏感度0.92(95%CI 0.85-0.95),特异度0.90(95%CI 0.84-0.94),阳性似然比6.19(95%CI 4.4-8.5),阴性似然比0.148(95%CI 0.09-0.22),SROC曲线下面积0.925(95%CI 0.84-0.927)。作者认为超声ONSD可能是有用的无创IICP诊断工具。
要点
- 非创伤性神经重症患者中,超声ONSD诊断IICP的汇总敏感度0.92(95%CI 0.85-0.95)、特异度0.90(95%CI 0.84-0.94)。
- 汇总阳性似然比6.19(95%CI 4.4-8.5)、阴性似然比0.148(95%CI 0.09-0.22),SROC曲线下面积0.925(95%CI 0.84-0.927)。
- 汇总诊断比值比44.7(95%CI 22.5-80.1),基于18项观察性研究、1484例成人患者。
- 有创与无创参照标准的亚组分析显示超声ONSD诊断准确性相似。
- 纳入病因包括中枢神经系统感染、颅内出血、急性缺血性卒中、动脉瘤性蛛网膜下腔出血、特发性颅内高压和缺氧缺血性脑损伤。
适用人群与场景
- 成人非创伤性神经重症患者,IICP病因包括中枢神经系统感染、颅内出血、急性缺血性卒中、动脉瘤性蛛网膜下腔出血、特发性颅内高压和缺氧缺血性脑损伤。
研究设计与关键结果
- 系统评价与Meta分析,纳入18项观察性研究、共1484例成人非创伤性神经重症患者,评估超声ONSD诊断IICP的准确性,参照标准为有创或无创方法。
- 汇总诊断比值比44.7(95%CI 22.5-80.1);汇总敏感度0.92(95%CI 0.85-0.95),特异度0.90(95%CI 0.84-0.94)。
- 汇总阳性似然比6.19(95%CI 4.4-8.5),阴性似然比0.148(95%CI 0.09-0.22);SROC曲线下面积0.925(95%CI 0.84-0.927)。
- 有创与无创参照标准的亚组分析显示超声ONSD诊断IICP的准确性相似。
证据类型、等级与局限
- 证据类型:诊断准确性系统评价与Meta分析,纳入18项观察性研究;采用QUADAS-2工具进行质量评价,异质性用I²统计量检验,采用双变量随机效应模型汇总。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,超声ONSD可能是非创伤性脑损伤患者IICP诊断中有用的无创工具。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Optic nerve sheath diameter (ONSD) assessed by ultrasound is a feasible bedside method for increased intracranial pressure (IICP) diagnosis. However, most of the evidence relies on the population of patients with traumatic brain injury, with few data available on other populations. Consequently, its efficacy in nontraumatic critically ill patients remains underexplored. Our purpose was to examine the accuracy of ONSD ultrasonography for diagnosing IICP in nontraumatic neurocritically ill patients.
METHODS: We conducted a systematic search of PubMed, Embase, and the Cochrane Library databases for comparative studies of adult nontraumatic critically ill patients that evaluated the accuracy of sonographic ONSD for IICP diagnosis compared with invasive or noninvasive reference standards. Two reviewers independently completed the search, data abstraction, and quality assessment with Quality Assessment of Diagnostic Accuracy Studies-2 tool. Heterogeneity was examined with I2 statistics. We used a bivariate model of random effects to summarize pooled diagnostic odds ratio, sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and summary receiver operating characteristic.
RESULTS: We included 18 observational studies, comprising 1,484 patients. Etiology of IICP was mixed, being composed of central nervous system infection, intracranial hemorrhage, acute ischemic stroke, aneurysmal subarachnoid hemorrhage, idiopathic intracranial hypertension, and hypoxic-ischemic brain injury. The pooled diagnostic odds ratio was 44.7 (95% confidence interval [CI] 22.5-80.1). Pooled sensitivity and specificity were 0.92 (95% CI 0.85-0.95) and 0.90 (95% CI 0.84-0.94), respectively, with a positive likelihood ratio of 6.19 (95% CI 4.4-8.5), and a negative likelihood ratio of 0.148 (95% CI 0.09-0.22). Summary receiver operating characteristic showed a calculated area under the curve of 0.925 (95% CI 0.84-0.927). Subgroup analysis of invasive and noninvasive reference standards showed similar accuracy of ultrasound ONSD for IICP diagnosis.
CONCLUSIONS: Ultrasound ONSD may be a potentially useful noninvansive tool for IICP diagnosis in patients with nontraumatic brain injury.
参考来源
- Melo RH, Gioli-Pereira L, Machado FS, et al. Optic Nerve Sheath Diameter Sonography for the Diagnosis of Increased Intracranial Pressure in Nontraumatic Neurocritically Ill Patients: a Diagnostic Accuracy Systematic Review and Meta-Analysis. Neurocrit Care. 2025. PMID: 40169492. doi:10.1007/s12028-025-02249-6
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。