SpO2/FiO2与PaO2/FiO2比值在机械通气ARDS患者中的临床表现:一项回顾性研究
该回顾性观察研究纳入258例已入组既往研究的机械通气ARDS患者,在ICU入院时及PEEP试验期间测量气体交换、SpO2和呼吸力学,用CT计算肺可复张性并评估肺分区。SpO2/FiO2与PaO2/FiO2呈非线性关联,动脉pH和PaCO2无影响;两者对ARDS严重程度分级呈中度一致性(组内相关系数=0.63)。对应严重程度分级之间,呼吸力学、气体交换、肺部影像特征及ICU死亡率无差异。SpO2/FiO2<235可检出89%静脉掺混>20%的患者,与PaO2/FiO2<200相似。作者认为SpO2/FiO2可更快速便捷地评估氧合障碍并分级ARDS严重程度,但结果可能不适用于不同患者人群,脉搏血氧仪仅为监测设备,信息应由医生根据患者特征和状况个体化解读。
要点
- 在258例机械通气ARDS患者中,SpO2/FiO2与PaO2/FiO2呈非线性关联,动脉pH和PaCO2对二者关系无影响。
- SpO2/FiO2与PaO2/FiO2对ARDS严重程度分级呈中度一致性,组内相关系数=0.63。
- 按SpO2/FiO2与PaO2/FiO2分级对应的类别之间,呼吸力学、气体交换、肺部影像特征及ICU死亡率均无差异,两个PEEP水平内亦然。
- SpO2/FiO2<235可检出89%静脉掺混>20%的患者,与PaO2/FiO2<200的检出能力相似。
- 作者认为SpO2/FiO2可更快速便捷地识别氧合障碍并分级ARDS严重程度,PEEP试验期间亦可使用。
适用人群与场景
- 258例机械通气ARDS患者,已入组既往研究,来自内科-外科ICU。
诊断标准与关键阈值
- SpO2/FiO2比值<235可检出89%静脉掺混>20%的患者,与PaO2/FiO2比值<200相似。
研究设计与关键结果
- 回顾性观察研究,纳入258例机械通气ARDS患者,在ICU入院时及PEEP试验期间测量气体交换、SpO2和呼吸力学,用CT数据计算肺可复张性并评估不同肺分区。
- SpO2/FiO2与PaO2/FiO2呈非线性关联;考虑脉搏血氧仪可能混杂因素后,动脉pH和PaCO2对二者关系无影响。
- SpO2/FiO2与PaO2/FiO2对ARDS严重程度分级呈中度一致性,组内相关系数=0.63。
- 按SpO2/FiO2与PaO2/FiO2分级对应的类别之间,呼吸力学、气体交换、肺部影像特征及ICU死亡率无差异,两个PEEP水平内亦然。
- SpO2/FiO2<235可检出89%静脉掺混>20%的患者,与PaO2/FiO2<200相似。
证据类型、等级与局限
- 证据类型:回顾性观察研究。
- 局限:作者指出结果可能不适用于不同患者人群;脉搏血氧仪仅为监测设备,信息应由医生根据患者特征和状况个体化解读。
对床旁实践的改变
- 作者认为SpO2/FiO2比值可更快速便捷地识别氧合障碍并分级ARDS严重程度,即使PEEP试验期间亦可使用。
- 作者指出结果可能不适用于不同患者人群;脉搏血氧仪仅为监测设备,信息应由医生根据患者特征和状况个体化解读。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: The present study aims to evaluate the severity classification of acute respiratory distress syndrome (ARDS) in mechanically ventilated patients according to peripheral oxygen saturation by pulse oximetry (Sp o2 )/F io2 ratio compared with Pa o2 /F io2 ratio and the relationship between Sp o2 /F io2 ratio and venous admixture.
DESIGN: Retrospective observational study.
SETTING: Medical-surgical ICU.
PATIENTS: A cohort of 258 mechanically ventilated patients with ARDS already enrolled in previous studies.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: Gas exchange, Sp o2 , and respiratory mechanics were measured on ICU admission and during the positive end-expiratory pressure (PEEP) trial. Radiological data from CTs were used to compute lung recruitability and to assess different lung compartments. A nonlinear association was found between Sp o2 /F io2 and Pa o2 /F io2 . Considering the possible confounding factors of the pulse oximeter on the relationship between Sp o2 /F io2 and Pa o2 /F io2 ratio, arterial pH, and Pa co2 had no effect. Sp o2 /F io2 and Pa o2 /F io2 ratio demonstrated a moderate agreement in classifying ARDS severity (intraclass correlation coefficient = 0.63). Between the correspondent classes according to Sp o2 /F io2 vs. Pa o2 /F io2 ratio-derived severity classifications, there was no difference in terms of respiratory mechanics, gas exchange, lung radiological characteristics and mortality in ICU, and within two levels of PEEP. A Sp o2 /F io2 ratio less than 235 was able to detect 89% of patients with a venous admixture greater than 20%, similarly to a Pa o2 /F io2 ratio less than 200.
CONCLUSIONS: Sp o2 /F io2 ratio can detect oxygenation impairment and classify ARDS severity similarly to Pa o2 /F io2 ratio in a more rapid and handy way, even during a PEEP trial. However, our results may not be applicable to different patient populations; in fact, the pulse oximeter is merely a monitoring device and the information should be personalized by the physician on the patient's characteristics and conditions.