文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

压力控制通气中的机械功率:一种简单可靠的床旁方法

Mechanical Power in Pressure-Controlled Ventilation: A Simple and Reliable Bedside Method.
PubMed 文献 · Crit Care Explor · 2025-03-03
一句话结论在压力控制通气无自主呼吸患者中,用包含平台压的新公式可在床旁准确估算机械功率,与金标准几何法偏倚仅0.2 J/min。

该初步研究在荷兰单中心ICU对42例患者共56例次无自主呼吸的机械通气进行机械功率测定。作者提出一种纳入平台压的简易公式,并与几何法金标准及其他四种已有公式比较。新公式与参考值的偏倚为0.2 J/min,95%一致性界限为-3.1至+3.4 J/min。作者认为该公式可靠、简单且准确,适合临床常规使用。

要点

  • 在56例次无自主呼吸的机械通气中,新公式(含平台压)估算机械功率与几何法金标准的偏倚为0.2 J/min,95%一致性界限-3.1至+3.4 J/min。
  • van der Meijden公式的偏倚为-0.8 J/min,95%一致性界限-3.8至1.9 J/min。
  • 综合Becher公式的偏倚为-1.9 J/min,95%一致性界限-3.7至0.0 J/min。
  • 简化Becher公式的偏倚为-2.4 J/min,95%一致性界限-4.5至-0.3 J/min。
  • 线性模型公式的偏倚为-1.9 J/min,95%一致性界限-3.7至0.1 J/min。

适用人群与场景

  • 在荷兰单大学医学中心ICU接受机械通气、无自主呼吸努力的患者,共42例患者56例次测量。

研究设计与关键结果

  • 研究类型为初步研究,在荷兰单中心ICU纳入42例无自主呼吸的机械通气患者,共56例次测量。
  • 新提出的含平台压公式估算的机械功率与几何法参考值偏倚为0.2 J/min,95%一致性界限为-3.1至+3.4 J/min。
  • van der Meijden公式偏倚-0.8 J/min,95%一致性界限-3.8至1.9 J/min。
  • 综合Becher公式偏倚-1.9 J/min,95%一致性界限-3.7至0.0 J/min。
  • 简化Becher公式偏倚-2.4 J/min,95%一致性界限-4.5至-0.3 J/min。
  • 线性模型公式偏倚-1.9 J/min,95%一致性界限-3.7至0.1 J/min。

证据类型、等级与局限

  • 证据类型:初步研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,所提出的压力控制通气机械功率计算公式是已有公式的可靠、简单且准确的替代方法,因而非常适合临床常规使用。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Mechanical power (MP) represents the amount of energy applied by the ventilator to the respiratory system over time. There are two main methods to calculate MP in mechanical ventilation. The first is the geometric method, which directly measures the dynamic inspiratory area of the pressure-volume loop during the respiratory cycle. The second involves using various algebraic equations to estimate MP. However, almost all calculations are either complex or not reliable compared with the geometric method, considered the gold standard. This study aimed to develop an easy to use, reliable equation for bedside calculation of MP and to compare its accuracy with other existing equations for calculating MP.

METHODS: In a preliminary study, we measured MP in 56 cases who were mechanically ventilated and without spontaneous breathing efforts. The measurements were done at the ICU of a single university medical center in the Netherlands.

RESULTS: We found that the MP can be accurately calculated using an equation that incorporates the plateau pressure in 56 cases in 42 patients. The MP estimated with our new proposed equation (MP calculated using plateau pressure) correlated well with the reference value of MP with a bias of 0.2 J/min. The 95% limits of agreement (LoAs) were -3.1 to + 3.4 J/min. Other equations give the following bias and LoAs; bias of -0.8, LoA -3.8 to 1.9 J/min (van der Meijden equation), bias of -1.9, LoA -3.7 to -0.0 J/min (comprehensive Becher equation), bias of -2.4, LoA -4.5 to -0.3 J/min (simplified Becher equation), and a bias of -1.9, LoA -3.7 to 0.1 J/min (linear model equation).

CONCLUSIONS: The equation we propose to calculate MP in pressure-controlled ventilation is a reliable, simple, and accurate alternative for the previously published equations. Consequently, this method is highly suitable for routine use in clinical practice.

来源:Crit Care Explor,查看原文。版权归原作者所有。