文献速递创伤与烧伤重症综合管理与镇静镇痛

定量测量髓源性抑制细胞检测创伤后感染效用的一项初步研究

A Pilot Study Assessing the Utility of Quantitative Myeloid-Derived Suppressor Cell Measurements in Detecting Posttraumatic Infection.
PubMed 文献 · Crit Care Explor · 2025-03-17
一句话结论单中心前瞻性初步研究显示,创伤后感染患者总髓源性抑制细胞计数高于无感染患者,ROC曲线下面积0.83,可能有助于指导进一步诊断检查。

本研究为单中心前瞻性观察性初步研究,纳入需要机械通气≥48小时的创伤患者,用11参数定量髓源性抑制细胞(MDSC)检测分析全血,并由两名医师盲法裁定感染。21例(54%)发生感染,11例(28%)死亡。感染患者总MDSC计数为696(368-974)个/μL,高于无感染患者的304(181-404)个/μL(p<0.001);淋巴细胞、中性粒细胞和CD45+白细胞计数在两组间无统计学差异;总MDSC区分感染与无感染的ROC曲线下面积为0.83(p<0.001)。作者认为MDSC计数可检测创伤后感染,可能有助于指导危重创伤患者的进一步诊断检查。

要点

  • 创伤后感染患者总MDSC计数为696(368-974)个/μL,高于无感染患者的304(181-404)个/μL(p<0.001)。
  • 总MDSC区分创伤后感染与无感染的ROC曲线下面积为0.83(p<0.001)。
  • 淋巴细胞、中性粒细胞和CD45+白细胞计数在感染与无感染组间无统计学差异。
  • 队列39例,79%为男性,中位年龄48岁(IQR 32-65),损伤严重度评分29(IQR 21-41),ICU住院13天(IQR 8-19)。
  • 21例(54%)发生感染,11例(28%)死亡。

适用人群与场景

  • 单中心前瞻性观察性初步研究,纳入需要机械通气≥48小时的创伤患者(n=39)。

研究设计与关键结果

  • 单中心前瞻性观察性初步研究,39例需要机械通气≥48小时的创伤患者,无干预。
  • 感染由两名医师通过盲法病历审查裁定;21例(54%)发生感染,11例(28%)死亡。
  • 感染患者总MDSC计数为696(368-974)个/μL,高于无感染患者的304(181-404)个/μL(p<0.001)。
  • 淋巴细胞、中性粒细胞和CD45+白细胞计数在感染与无感染组间无统计学差异。
  • 总MDSC区分感染与无感染的ROC曲线下面积为0.83(p<0.001)。

证据类型、等级与局限

  • 证据类型:单中心前瞻性观察性初步研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,定量全血流式细胞术测定的MDSC计数可检测创伤后感染,可能有助于指导危重创伤患者的进一步诊断检查。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: Biomarkers that facilitate earlier diagnosis of posttraumatic infection could improve outcomes by expediting treatment and mitigating complications, including sepsis. We hypothesized that circulating myeloid-derived suppressor cell (MDSC) counts could identify patients with posttraumatic infection.

DESIGN, SETTING, AND PATIENTS: We conducted a single-center, prospective observational pilot study of trauma victims who required greater than or equal to 48 hours of mechanical ventilation. Whole blood was collected and tested by flow cytometry.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN RESULTS: Samples were analyzed in real-time with an 11-parameter quantitative MDSC assay. Two physician adjudications of infection were performed through a blinded review of medical records. MDSC and other cell counts were compared between subjects with and without posttraumatic infection using non-parametric methods. Data are presented as medians (25th-75th percentile). The area under the receiver operating characteristic (ROC) curves were used to assess the accuracy of cell counts for diagnosing infection. Most subjects (n = 39) were male (79%) with a median age of 48 (interquartile range [IQR] 32-65), Injury Severity Score of 29 (IQR 21-41), and ICU length of stay of 13 days (IQR 8-19). Twenty-one (54%) developed an infection and 11 (28%) of the cohort died. We compared total MDSC (T-MDSC) counts closest to the day of infection diagnosis with the initial T-MDSC counts in subjects without infection. T-MDSC counts were higher in those with infection compared to those without infection (696 [368-974] and 304 [181-404] cells/μL, respectively; p < 0.001). Lymphocyte, neutrophil, and CD45+ leukocyte counts were not statistically different between the groups. The area under the ROC curve distinguishing those with infection from those without for T-MDSC was 0.83 (p < 0.001).

CONCLUSIONS: MDSC counts determined by quantitative whole blood flow cytometrics can detect posttraumatic infection and may be useful to guide further diagnostic testing in critically ill trauma victims.

来源:Crit Care Explor,查看原文。版权归原作者所有。

参考来源

  1. O'Keefe GE, Wu Y, Mirabadi N, et al. A Pilot Study Assessing the Utility of Quantitative Myeloid-Derived Suppressor Cell Measurements in Detecting Posttraumatic Infection. Crit Care Explor. 2025. PMID: 40100961. doi:10.1097/CCE.0000000000001228

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。