文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

动态肺顺应性标准化机械能与机械通气患者撤机结局及预后的相关性分析

[Correlation analysis between mechanical power normalized to dynamic lung compliance and weaning outcomes and prognosis in mechanically ventilated patients: a prospective, observational cohort study].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2025-01-01
一句话结论Cdyn-MP与撤机失败独立相关(OR=1.190,95%CI 1.086-1.309,P<0.001),预测撤机失败的AUC为0.761。

该前瞻性观察性队列研究纳入2022年1月至2023年12月连云港市第一人民医院和第二人民医院ICU中接受有创机械通气超过24小时并以T管通气策略撤机的366例患者,其中撤机成功243例、撤机失败123例。撤机失败组SOFA评分、SBT期间体温和呼吸频率、SBT前4小时内PEEP、Pplat、Ppeak、ΔPaw、FiO2、MP及Cdyn-MP均显著升高,Cdyn显著降低,有创通气时间、ICU住院时间和总住院时间显著延长。多因素Logistic回归显示SOFA评分(OR=1.081,95%CI 1.008-1.160,P=0.030)、PEEP(OR=1.191,95%CI 1.075-1.329,P=0.001)、FiO2(OR=1.035,95%CI 1.006-1.068,P=0.021)和Cdyn-MP(OR=1.190,95%CI 1.086-1.309,P<0.001)是撤机失败的独立危险因素。Cdyn-MP预测撤机失败的AUC为0.761(95%CI 0.712-0.810,P<0.001),最佳截断值408.5 J/min×cmH2O/mL×10-3时敏感度68.29%、特异度71.19%。

要点

  • SBT前4小时内Cdyn-MP是撤机失败的独立危险因素(OR=1.190,95%CI 1.086-1.309,P<0.001)。
  • Cdyn-MP预测撤机失败的AUC为0.761(95%CI 0.712-0.810,P<0.001),最佳截断值408.5 J/min×cmH2O/mL×10-3,敏感度68.29%、特异度71.19%。
  • SBT前4小时内PEEP(OR=1.191,95%CI 1.075-1.329,P=0.001)和FiO2(OR=1.035,95%CI 1.006-1.068,P=0.021)也是撤机失败的独立危险因素。
  • SOFA评分是撤机失败的独立危险因素(OR=1.081,95%CI 1.008-1.160,P=0.030)。
  • Cdyn-MP与ΔPaw(r=0.773,P<0.01)、MP(r=0.865,P<0.01)正相关,与Cdyn负相关(r=-0.587,P<0.01)。

适用人群与场景

  • 2022年1月至2023年12月连云港市第一人民医院和第二人民医院ICU中接受有创机械通气超过24小时、采用T管通气策略撤机的患者。
  • 共纳入366例,撤机成功243例,撤机失败123例;其中23例在首次SBT成功撤机后48小时内再插管、无创通气或死亡。

诊断标准与关键阈值

  • 撤机失败定义:首次SBT成功撤机后48小时内再插管、无创通气或死亡。
  • Cdyn-MP预测撤机失败的最佳截断值为408.5 J/min×cmH2O/mL×10-3,敏感度68.29%,特异度71.19%。

研究设计与关键结果

  • 研究类型:前瞻性观察性队列研究;纳入366例有创机械通气患者,撤机成功组243例 vs 撤机失败组123例。
  • 撤机失败组较撤机成功组SOFA评分、SBT期间体温和呼吸频率、SBT前4小时内通气频率、PEEP、Pplat、Ppeak、ΔPaw、FiO2、MP及Cdyn-MP均显著升高,Cdyn显著降低,有创通气时间、ICU住院时间和总住院时间显著延长。
  • 两组年龄、性别、BMI、吸烟史、主要入ICU原因、SBT期间心率、平均动脉压、SpO2及白细胞计数、白蛋白、血清肌酐无统计学显著差异。
  • 多因素Logistic回归:SOFA评分OR=1.081(95%CI 1.008-1.160,P=0.030)、PEEP OR=1.191(95%CI 1.075-1.329,P=0.001)、FiO2 OR=1.035(95%CI 1.006-1.068,P=0.021)、Cdyn-MP OR=1.190(95%CI 1.086-1.309,P<0.001)为撤机失败独立危险因素。
  • 限制性立方样条分析(校正混杂因素后)显示,SBT前4小时内Cdyn-MP升高,撤机失败风险显著增加(P<0.001)。
  • Spearman秩相关:SBT前4小时内Cdyn-MP与ΔPaw(r=0.773,P<0.01)和MP(r=0.865,P<0.01)正相关,与Cdyn负相关(r=-0.587,P<0.01);与有创通气时间(r=0.295)、ICU住院时间(r=0.196)、总住院时间(r=0.120)正相关(均P<0.05)。
  • ROC曲线分析:SBT前4小时内Cdyn-MP、MP、Cdyn、ΔPaw对撤机失败均有预测价值,Cdyn-MP预测能力更优,AUC=0.761(95%CI 0.712-0.810,P<0.001)。

证据类型、等级与局限

  • 证据类型:前瞻性观察性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为Cdyn-MP与机械通气患者撤机结局和预后相关,在评估撤机失败风险方面具有良好预测能力。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To explore the correlation between mechanical power normalized to dynamic lung compliance (Cdyn-MP) and weaning outcomes and prognosis in mechanically ventilated patients.

METHODS: A prospective, observational cohort study was conducted. Patients who underwent invasive mechanical ventilation (IMV) for more than 24 hours and used a T-tube ventilation strategy for extubation in the intensive care unit (ICU) of Lianyungang First People's Hospital and Lianyungang Second People's Hospital between January 2022 and December 2023 were enrolled. The collected data encompassed patients' baseline characteristics, primary causes of ICU admission, vital signs and laboratory indicators during the initial spontaneous breathing trial (SBT), respiratory mechanics parameters within the 4-hour period prior to the SBT, weaning outcomes and prognostic indicators. Mechanical power (MP) and Cdyn-MP were calculated using a simplified MP equation. Univariate and multivariate Logistic regression analyses were utilized to determine the independent risk factors associated with weaning failure in patients undergoing mechanical ventilation. Restricted cubic spline (RCS) analysis and Spearman rank-sum test were employed to investigate the correlation between Cdyn-MP and weaning outcomes as well as prognosis. Receiver operator characteristic curve (ROC curve) was constructed, and the area under the ROC curve (AUC) was computed to evaluate the predictive accuracy of Cdyn-MP for weaning outcomes in mechanically ventilated patients.

RESULTS: A total of 366 patients undergoing IMV were enrolled in this study, with 243 cases classified as successful weaning and 123 cases classified as failed weaning. Among them, 23 patients underwent re-intubation within 48 hours after the successful withdrawal of the first SBT, non-invasive ventilation, or died. Compared with the successful weaning group, the patients in the failed weaning group had significantly increased levels of sequential organ failure assessment (SOFA) score, body temperature and respiratory rate (RR) during SBT, and respiratory mechanical parameters within the 4-hour period prior to the SBT [ventilation frequency, positive end-expiratory pressure (PEEP), platform pressure (Pplat), peak inspiratory pressure (Ppeak), dynamic driving pressure (ΔPaw), fraction of inspired oxygen (FiO2), MP, and Cdyn-MP], dynamic lung compliance (Cdyn) was significantly reduced, and duration of IMV, ICU length of stay, and total length of hospital stay were significantly prolonged. However, there were no statistically significant differences in age, gender, body mass index (BMI), smoking history, main causes of ICU admission, other vital signs [heart rate (HR), mean arterial pressure (MAP), saturation of peripheral oxygen (SpO2)] and laboratory indicators [white blood cell count (WBC), albumin (Alb), serum creatinine (SCr)] during SBT of patients between the two groups. Univariate Logistic regression analysis was conducted, and variables with P < 0.05 and no multicollinearity with Cdyn-MP were selected for inclusion in the multivariate Logistic regression model. The results demonstrated that SOFA score [odds ratio (OR) = 1.081, 95% confidence interval (95%CI) was 1.008-1.160, P = 0.030], and PEEP (OR = 1.191, 95%CI was 1.075-1.329, P = 0.001), FiO2 (OR = 1.035, 95%CI was 1.006-1.068, P = 0.021) and Cdyn-MP (OR = 1.190, 95%CI was 1.086-1.309, P < 0.001) within the 4-hour period prior to the SBT were independent risk factors for weaning failure in patients undergoing IMV. The RCS analysis after adjusting for confounding factors showed that as Cdyn-MP within the 4-hour period prior to the SBT increased, the risk of weaning failure in patients undergoing IMV significantly increased (P < 0.001). The Spearman rank correlation test showed that Cdyn-MP within the 4-hour period prior to the SBT was positively correlated with respiratory mechanical parameters including ΔPaw and MP (r values were 0.773 and 0.865, both P < 0.01), and negatively correlated with Cdyn (r = -0.587, P < 0.01). Cdyn-MP within the 4-hour period prior to the SBT was positively correlated with prognostic indicators such as duration of IMV, length of ICU stay, and total length of hospital stay (r values were 0.295, 0.196, and 0.120, all P < 0.05). ROC curve analysis demonstrated that, within the 4-hour period preceding the SBT, Cdyn-MP, MP, Cdyn, and ΔPaw possessed predictive value for weaning failure in patients undergoing IMV. Notably, Cdyn-MP exhibited superior predictive capability, evidenced by an AUC of 0.761, with a 95%CI ranging from 0.712 to 0.810 (P < 0.001). At the optimal cut-off value of 408.5 J/min×cmH2O/mL×10-3, the sensitivity was 68.29%, and the specificity was 71.19%.

CONCLUSION: Cdyn-MP is related to weaning outcomes and prognosis in mechanically ventilated patients, and has good predictive ability in assessing the risk of weaning failure.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Yan Y, Xie Y, Du Z, et al. [Correlation analysis between mechanical power normalized to dynamic lung compliance and weaning outcomes and prognosis in mechanically ventilated patients: a prospective, observational cohort study]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2025. PMID: 39968584. doi:10.3760/cma.j.cn121430-20240126-00085

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。