机械功率与COVID-19机械通气患者死亡率无关
本研究为CIBERESUCICOVID项目的二次分析,纳入西班牙50个重症监护病房2020年2月至2021年12月期间799例接受有创机械通气的COVID-19诱导呼吸衰竭患者,评估机械功率及其组分(弹性静态、弹性动态、总弹性及阻力功率)与90天死亡率的相关性。结果显示,机械通气开始时PaO2/FiO2为106(78;150),通气比为1.69(1.40;2.05),呼吸系统顺应性为35.7(29.2;44.5)ml/cmH2O,机械功率为24.3(18.9;29.6)J/min,3天后无显著变化。多变量回归分析中,机械通气开始时机械功率及其组分与90天死亡率无关;3天后总弹性功率和弹性静态功率与90天死亡率升高相关,但呼气末正压也显示相同关系。结论认为,在COVID-19诱导的急性呼吸衰竭机械通气开始时,机械功率及其组分与死亡率无独立关联;3天后静态弹性功率和总弹性功率与生存率降低相关,但呼气末正压和平台压以类似方式捕捉到该风险。
要点
- 在799例COVID-19机械通气患者中,机械通气开始时机械功率为24.3(18.9;29.6)J/min,3天后无显著变化。
- 多变量回归分析显示,机械通气开始时机械功率及其组分(弹性静态、弹性动态、总弹性及阻力功率)与90天死亡率无关。
- 机械通气3天后,总弹性功率和弹性静态功率与90天死亡率升高相关,但呼气末正压也显示相同关系。
- 机械通气开始时PaO2/FiO2为106(78;150),通气比为1.69(1.40;2.05),呼吸系统顺应性为35.7(29.2;44.5)ml/cmH2O。
适用人群与场景
- 西班牙50个重症监护病房中,2020年2月至2021年12月期间纳入的COVID-19诱导急性呼吸衰竭接受有创机械通气的患者。
研究设计与关键结果
- 研究类型:CIBERESUCICOVID项目的二次分析,多中心观察性队列研究,纳入799例COVID-19诱导呼吸衰竭接受有创机械通气的患者。
- 机械通气开始时:PaO2/FiO2为106(78;150),通气比为1.69(1.40;2.05),呼吸系统顺应性为35.7(29.2;44.5)ml/cmH2O,机械功率为24.3(18.9;29.6)J/min,3天后无显著变化。
- 多变量回归分析:机械通气开始时,机械功率及其组分(弹性静态、弹性动态、总弹性及阻力功率)与90天死亡率无关。
- 机械通气3天后:总弹性功率和弹性静态功率与90天死亡率升高相关,但呼气末正压也显示相同关系;呼气末正压和平台压以类似方式捕捉到该风险。
证据类型、等级与局限
- 证据类型:多中心观察性队列研究的二次分析。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,在COVID-19诱导的急性呼吸衰竭机械通气开始时,机械功率及其组分与死亡率无独立关联;3天后静态弹性功率和总弹性功率与生存率降低相关,但呼气末正压和平台压以类似方式捕捉到该风险。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: The relative contribution of the different components of mechanical power to mortality is a subject of debate and has not been studied in COVID-19. The aim of this study is to evaluate both the total and the relative impact of each of the components of mechanical power on mortality in a well-characterized cohort of patients with COVID-19-induced acute respiratory failure undergoing invasive mechanical ventilation. This is a secondary analysis of the CIBERESUCICOVID project, a multicenter observational cohort study including fifty Spanish intensive care units that included COVID-19 mechanically ventilated patients between February 2020 and December 2021. We examined the association between mechanical power and its components (elastic static, elastic dynamic, total elastic and resistive power) with 90-day mortality after adjusting for confounders in seven hundred ninety-nine patients with COVID-19-induced respiratory failure undergoing invasive mechanical ventilation.
RESULTS: At the initiation of mechanical ventilation, the PaO2/FiO2 ratio was 106 (78; 150), ventilatory ratio was 1.69 (1.40; 2.05), and respiratory system compliance was 35.7 (29.2; 44.5) ml/cmH2O. Mechanical power at the initiation of mechanical ventilation was 24.3 (18.9; 29.6) J/min, showing no significant changes after three days. In multivariable regression analyses, mechanical power and its components were not associated with 90-day mortality at the start of mechanical ventilation. After three days, total elastic and elastic static power were associated with higher 90-day mortality, but this relationship was also found for positive end-expiratory pressure.
CONCLUSIONS: Neither mechanical power nor its components were independently associated with mortality in COVID-19-induced acute respiratory failure at the start of MV. Nevertheless, after three days, static elastic power and total elastic power were associated with lower odds of survival. Positive end-expiratory pressure and plateau pressure, however, captured this risk in a similar manner.
参考来源
- Barbeta E, Barreiros C, Forin E, et al. Mechanical power is not associated with mortality in COVID-19 mechanically ventilated patients. Ann Intensive Care. 2025. PMID: 39998751. doi:10.1186/s13613-025-01430-6
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。