文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

改良袖带漏气试验预测有创机械通气患者再插管风险:多中心、单盲、随机对照试验

Modified Cuff Leak Test for Predicting the Risk of Reintubation in Patients With Invasive Mechanical Ventilation: A Multicenter, Single-Anonymized, Randomized Controlled Trial.
PubMed 文献 · Chest · 2025-02-06
一句话结论改良袖带漏气试验未降低48小时内再插管率,但可能更好预测拔管后24小时内喘鸣,尤其在机械通气≥6天者。

这项前瞻性、多中心、随机对照试验纳入536例有创机械通气患者,随机分为改良袖带漏气试验组(n=268)和对照组(n=268)。主要终点拔管后48小时内再插管需求发生率两组无差异。改良组拔管后24小时内喘鸣发生率高于对照组(5.22% vs 1.49%;OR,0.275 [95% CI,0.089-0.846];P=.028),有创机械通气时间短于对照组(137小时 [74,218] vs 159小时 [95,252];OR,1.001 [95% CI,1.000-1.002];P=.046)。在机械通气≥6天的患者中,改良组喘鸣发生率为2.95%,对照组为0.74%(OR,0.203 [95% CI,0.042-0.975];P=.048)。作者认为改良袖带漏气试验可能更好预测拔管后24小时内喘鸣,但未显示降低再插管发生率和死亡率。

要点

  • 改良袖带漏气试验组与对照组48小时内再插管需求发生率无差异。
  • 改良组拔管后24小时内喘鸣发生率高于对照组(5.22% vs 1.49%;OR,0.275 [95% CI,0.089-0.846];P=.028)。
  • 改良组有创机械通气时间短于对照组(137小时 [74,218] vs 159小时 [95,252];OR,1.001 [95% CI,1.000-1.002];P=.046)。
  • 机械通气≥6天患者中,改良组喘鸣发生率为2.95%,对照组为0.74%(OR,0.203 [95% CI,0.042-0.975];P=.048)。
  • 作者认为改良袖带漏气试验可能更好预测拔管后24小时内喘鸣,但未显示降低再插管发生率和死亡率。

适用人群与场景

  • 接受有创机械通气的成人患者,来自多中心随机对照试验人群。

研究设计与关键结果

  • 研究类型为前瞻性、多中心、随机对照试验,共随机536例患者,改良袖带漏气试验组n=268,对照组n=268。
  • 主要终点拔管后48小时内再插管需求发生率两组无差异。
  • 拔管后24小时内喘鸣发生率改良组高于对照组(5.22% vs 1.49%;OR,0.275 [95% CI,0.089-0.846];P=.028)。
  • 有创机械通气时间改良组短于对照组(137小时 [74,218] vs 159小时 [95,252];OR,1.001 [95% CI,1.000-1.002];P=.046)。
  • 机械通气≥6天患者中,拔管后喘鸣发生率改良组为2.95%,对照组为0.74%(OR,0.203 [95% CI,0.042-0.975];P=.048)。
  • 作者认为改良袖带漏气试验未显示降低再插管发生率和死亡率。

证据类型、等级与局限

  • 证据类型:前瞻性、多中心、随机对照试验(单盲)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为改良袖带漏气试验可能更好预测拔管后24小时内喘鸣,尤其对机械通气时间超过6天的患者,但未显示降低再插管发生率和死亡率。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The cuff leak test (CLT) is an important tool to assess the risk of upper airway obstruction after extubation.

RESEARCH QUESTION: Does a modified CLT approach have superior ability in predicting reintubation compared with the traditional method?

STUDY DESIGN AND METHODS: This was a prospective, multicenter, randomized controlled trial. The primary end point was the incidence of the need for reintubation within 48 hours of extubation. Secondary end points included, among others, the actual incidence of reintubation, the incidence of postextubation stridor (PES), and the duration of invasive mechanical ventilation (IMV).

RESULTS: A total of 536 patients were randomized to either the modified CLT group (n = 268) or the control group (n = 268). The incidence of reintubation within 48 hours of extubation did not differ between the groups. PES within 24 hours of extubation was more frequent in the modified CLT group than in the control group (5.22% vs 1.49%; OR, 0.275 [95% CI, 0.089-0.846]; P = .028). The IMV duration was shorter in the modified CLT group than in the control group (137 hours [74, 218] vs 159 hours [95, 252]; OR, 1.001 [95% CI, 1.000-1.002]; P = .046). In the patients with IMV duration ≥ 6 days, the incidence of PES was 2.95% in the modified CLT group and 0.74% in the control group (OR, 0.203 [95% CI, 0.042-0.975]; P = .048).

INTERPRETATION: Compared with the control group, the modified CLT approach might better predict PES within 24 hours of extubation, especially for patients with IMV duration longer than 6 days, but it was not shown to decrease the reintubation incidence and mortality.

CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT05550220; URL: clinicaltrials.gov.

来源:Chest,查看原文。版权归原作者所有。

参考来源

  1. Tang X, Gu YM, Shi Y, et al. Modified Cuff Leak Test for Predicting the Risk of Reintubation in Patients With Invasive Mechanical Ventilation: A Multicenter, Single-Anonymized, Randomized Controlled Trial. Chest. 2025. PMID: 39922534. doi:10.1016/j.chest.2025.01.033

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。