床旁超声预测无脉性电活动患者复苏结局的预后准确性:系统评价与Meta分析
该研究为系统评价与Meta分析,检索PubMed、Embase和Cochrane CENTRAL,纳入18项研究共1202例无脉性电活动(PEA)患者,用双变量模型汇总床旁超声(POCUS)检出心脏活动预测复苏结局的敏感度、特异度和SROC曲线下面积。结果:预测自主循环恢复的汇总敏感度0.86(95%CI 0.67-0.95)、特异度0.64(95%CI 0.51-0.75);预测存活入院敏感度0.89(95%CI 0.80-0.94)、特异度0.73(95%CI 0.63-0.81);预测存活出院敏感度0.79(95%CI 0.58-0.91)、特异度0.58(95%CI 0.47-0.68)。存活入院的SROC曲线下面积最高,为0.89(95%CI 0.86-0.92)。作者认为POCUS可能作为多模式方法的重要组成,用于早期终止复苏。
要点
- PEA患者床旁超声检出心脏活动预测存活入院的汇总敏感度0.89(95%CI 0.80-0.94)、特异度0.73(95%CI 0.63-0.81),SROC曲线下面积0.89(95%CI 0.86-0.92)。
- 预测自主循环恢复的汇总敏感度0.86(95%CI 0.67-0.95)、特异度0.64(95%CI 0.51-0.75)。
- 预测存活出院的汇总敏感度0.79(95%CI 0.58-0.91)、特异度0.58(95%CI 0.47-0.68)。
- 作者认为POCUS可能作为多模式方法的重要组成,用于早期终止复苏。
适用人群与场景
- 无脉性电活动(PEA)患者,共1202例(18项研究)。
研究设计与关键结果
- 系统评价与Meta分析,检索PubMed、Embase和Cochrane Central Register of Controlled Trials,纳入18项研究共1202例PEA患者,采用双变量模型汇总。
- 床旁超声检出心脏活动预测自主循环恢复:汇总敏感度0.86(95%CI 0.67-0.95)、特异度0.64(95%CI 0.51-0.75)。
- 预测存活入院(SHA):汇总敏感度0.89(95%CI 0.80-0.94)、特异度0.73(95%CI 0.63-0.81)。
- 预测存活出院:汇总敏感度0.79(95%CI 0.58-0.91)、特异度0.58(95%CI 0.47-0.68)。
- SROC曲线下面积最高为存活入院,0.89(95%CI 0.86-0.92)。
证据类型、等级与局限
- 证据类型:系统评价与Meta分析(18项研究,1202例)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为床旁超声可能作为多模式方法的重要组成,用于早期终止复苏。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: The prognosis for pulseless electrical activity (PEA) is typically poor; however, patients with cardiac activity observed on point-of-care ultrasound (POCUS) tend to have better outcomes compared to those without. This systematic review and meta-analysis were conducted to assess the prognostic accuracy of cardiac activity detected by POCUS in predicting resuscitation outcomes in patients experiencing PEA.
METHODS: A comprehensive literature search was conducted in PubMed, Embase, and the Cochrane Central Register of Controlled Trials to identify relevant studies. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio, and the area under the summary receiver operating characteristic curve (SROC) were calculated using the bivariate model.
RESULTS: Eighteen studies comprising 1202 patients were included in the meta-analysis. Cardiac activity observed on POCUS demonstrated a pooled sensitivity of 0.86 (95% CI 0.67-0.95) and specificity of 0.64 (95% CI 0.51-0.75) for predicting return of spontaneous circulation, a pooled sensitivity of 0.89 (95% CI 0.80-0.94) and specificity of 0.73 (95% CI 0.63-0.81) for survival to admission (SHA), and a pooled sensitivity of 0.79 (95% CI 0.58-0.91) and specificity of 0.58 (95% CI 0.47-0.68) for survival to discharge. The highest area under the SROC, 0.89 (95% CI 0.86-0.92), was observed for SHA.
CONCLUSIONS: Our study suggests that POCUS may serve as a vital component of a multimodal approach for early termination of resuscitation.
参考来源
- Jian SZ, Cheng TH, Yen CC, et al. Prognostic accuracy of point-of-care ultrasound in patients with pulseless electrical activity: a systematic review and meta-analysis. Scand J Trauma Resusc Emerg Med. 2025. PMID: 39930527. doi:10.1186/s13049-025-01327-0
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。