不同拔管技术对重症监护病房机械通气患者拔管效果比较
该前瞻性随机对照研究纳入2023年7月至11月广西医科大学第一附属医院重症医学科机械通气患者,随机分为负压组、正压1组(PS 7 cmH2O、PEEP 5 cmH2O)和正压2组(PS 15 cmH2O、PEEP 10 cmH2O),每组45例,最终每组42例。结果显示正压1组和正压2组拔管后呼吸急促、剧烈咳嗽、咽喉疼痛、上气道梗阻痉挛、低氧血症和高碳酸血症的发生率均低于负压组(均P<0.05),两正压组间无显著差异;拔管后1分钟和30分钟正压1组和正压2组血氧饱和度均高于负压组(均P<0.05)。结论认为正压拔管可有效减少拔管相关并发症,有利于维持拔管后30分钟内血氧饱和度稳定,推荐采用低压拔管。
要点
- 正压1组(PS 7 cmH2O、PEEP 5 cmH2O)拔管后呼吸急促7.14%、剧烈咳嗽7.14%、咽喉疼痛61.90%、上气道梗阻痉挛11.90%、低氧血症7.14%、高碳酸血症4.76%,均低于负压组的33.33%、28.57%、88.10%、45.24%、30.95%、28.57%(均P<0.05)。
- 正压2组(PS 15 cmH2O、PEEP 10 cmH2O)拔管后呼吸急促9.52%、剧烈咳嗽4.76%、咽喉疼痛52.38%、上气道梗阻痉挛19.05%、低氧血症7.14%、高碳酸血症2.38%,均低于负压组(均P<0.05)。
- 正压1组与正压2组拔管相关并发症无显著差异;三组拔管失败率无统计学显著差异。
- 拔管后1分钟和30分钟,正压1组和正压2组血氧饱和度均高于负压组(1分钟:0.97±0.02、0.97±0.02 vs. 0.95±0.02;30分钟:1.00±0.01、1.00±0.01 vs. 0.99±0.02,均P<0.05)。
- 作者推荐采用低压拔管。
适用人群与场景
- 2023年7月至11月广西医科大学第一附属医院重症医学科收治的机械通气患者。
处置流程与药物剂量
- 负压组在常规护理基础上采用负压拔管技术拔除气管导管。
- 正压1组在常规护理基础上采用正压拔管,压力支持(PS)为7 cmH2O(1 cmH2O≈0.098 kPa)、呼气末正压(PEEP)为5 cmH2O。
- 正压2组在常规护理基础上采用正压拔管,PS为15 cmH2O、PEEP为10 cmH2O。
研究设计与关键结果
- 前瞻性随机对照研究,纳入2023年7月至11月广西医科大学第一附属医院重症医学科机械通气患者,按Excel随机数字表分为负压组、正压1组和正压2组,每组45例,最终每组42例。
- 三组性别、年龄、导管留置天数、机械通气时间、急性生理学与慢性健康状况评分Ⅱ(APACHEⅡ)、导管型号和诊断比较均无显著差异,具有可比性。
- 三组呼吸急促、剧烈咳嗽、咽喉疼痛、上气道梗阻痉挛、低氧血症和高碳酸血症发生率比较,差异均有统计学意义;拔管失败率差异无统计学意义。
- 正压1组和正压2组拔管后呼吸急促发生率分别为7.14%、9.52%,均低于负压组的33.33%;剧烈咳嗽分别为7.14%、4.76%,均低于负压组的28.57%;咽喉疼痛分别为61.90%、52.38%,均低于负压组的88.10%;上气道梗阻痉挛分别为11.90%、19.05%,均低于负压组的45.24%;低氧血症分别为7.14%、7.14%,均低于负压组的30.95%;高碳酸血症分别为4.76%、2.38%,均低于负压组的28.57%(均P<0.05)。
- 正压1组与正压2组拔管相关并发症比较无显著差异。
- 三组拔管后30分钟内心率、收缩压、舒张压、平均动脉压和血氧饱和度时间效应差异均有统计学意义(F值分别为145.792、49.749、22.486、23.622、242.664,均P<0.01)。
- 血氧饱和度组间效应有统计学意义(F=3.835,P=0.024),拔管后1分钟和30分钟正压1组和正压2组血氧饱和度均高于负压组(1分钟:0.97±0.02、0.97±0.02 vs. 0.95±0.02;30分钟:1.00±0.01、1.00±0.01 vs. 0.99±0.02,均P<0.05)。
- 心率和血氧饱和度的交互效应有统计学意义(F值分别为3.512、7.226,均P<0.01)。
证据类型、等级与局限
- 证据类型:前瞻性随机对照研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 与负压拔管相比,正压拔管可有效减少ICU机械通气患者拔管相关并发症。
- 正压拔管有利于维持拔管后30分钟内血氧饱和度稳定,临床应用效果较好。
- 作者推荐采用低压拔管。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare the application effects of three different extubation techniques in patients with mechanical ventilation in intensive care unit (ICU).
METHODS: A prospective randomized controlled study was conducted. Mechanical ventilation patients admitted to the critical care department of the First Affiliated Hospital of Guangxi Medical University from July to November 2023 were enrolled. According to the random number table generated by Excel, the patients were divided into negative pressure group, positive pressure group 1 and positive pressure group 2, with 45 cases in each group. On the basis of routine nursing, the negative pressure group used the negative pressure extubation technique to remove the tracheal catheter. In the positive pressure group, the pressure support (PS) and positive end-expiratory pressure (PEEP) of the positive pressure group 1 were 7 cmH2O (1 cmH2O≈0.098 kPa) and 5 cmH2O, and the PS and PEEP of the positive pressure group 2 were 15 cmH2O and 10 cmH2O. The main outcome measures were extubation related complications, including tachypnea, severe cough, sore throat, upper airway obstruction spasm, extubation failure, hypoxemia, and hypercapnia. The secondary outcome measures were the variation of heart rate, systolic blood pressure, diastolic blood pressure, mean arterial pressure and blood oxygen saturation before and 1, 15 and 30 minutes after extubation.
RESULTS: Finally, 42 patients were included in each group. There were no significant differences in gender, age, catheter retention days, duration of mechanical ventilation, acute physiology and chronic health evaluation II (APACHE II), catheter model and diagnosis among the three groups, which were comparable. There were statistically significant differences in the incidence of tachypnea, severe cough, sore throat, upper airway obstruction spasm, hypoxemia and hypercapnia among the three groups, while there was no statistically significant difference in the failure rate of extubation. The incidence of tachypnea, severe cough, sore throat, upper airway obstruction spasm, hypoxemia and hypercapnia after extubation in positive pressure group 1 and positive pressure group 2 were lower than those in negative pressure group (7.14%, 9.52% vs. 33.33%; 7.14%, 4.76% vs. 28.57%; 61.90%, 52.38% vs. 88.10%; 11.90%, 19.05% vs. 45.24%; 7.14%, 7.14% vs. 30.95%; 4.76%, 2.38% vs. 28.57%; all P < 0.05). There were no significant differences in extubation related complications between group 1 and group 2. There were significant differences in the time effect of heart rate, systolic blood pressure, diastolic blood pressure, mean arterial pressure and blood oxygen saturation 30 minutes after extubation among three groups (F values were 145.792, 49.749, 22.486, 23.622 and 242.664, respectively, all P < 0.01). The intergroup effect of blood oxygen saturation was statistically significant (F = 3.835, P = 0.024), and the blood oxygen saturation in positive pressure group 1 and positive pressure group 2 were higher than those in negative pressure group 1 minute and 30 minutes after extubation (1 minute after extubation: 0.97±0.02, 0.97±0.02 vs. 0.95±0.02; 30 minutes after extubation: 1.00±0.01, 1.00±0.01 vs. 0.99±0.02, all P < 0.05). The interaction effects of heart rate and blood oxygen saturation were statistically significant (F values were 3.512 and 7.226, respectively, both P < 0.01).
CONCLUSIONS: Compared with negative pressure extubation, positive pressure extubation can effectively reduce extubation related complications in ICU mechanically ventilated patients. It is beneficial to maintain stable blood oxygen saturation within 30 minutes after extubation, and has better clinical application effects. It is recommended to use low pressure extubation.
参考来源
- Zhao R, Liu Y, Huang Y, et al. [Comparison of the effect of different extubation techniques on extubation in patients with mechanical ventilation in intensive care unit]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2024. PMID: 39697020. doi:10.3760/cma.j.cn121430-20231107-00950
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。