血液细胞回收对静脉-静脉体外膜氧合撤管后输血需求的影响:一项模拟试验分析
该研究为在英国两家ECMO中心开展的模拟试验,纳入841例接受VV-ECMO撤管的患者,比较撤管时血液细胞回收(BCS)与未行血液细胞回收(n-BCS),采用逆倾向治疗加权控制混杂,估计BCS对撤管后2天内输注浓缩红细胞(PRBC)及血红蛋白(Hb)变化的平均处理效应。结果显示BCS组估计边际平均输注PRBC为0.2单位(95%CI 0.16, 0.25),n-BCS组为0.51单位(95%CI 0.44, 0.59),平均处理效应为-0.31单位(95%CI -0.40, -0.22);BCS使接受任何PRBC输血的风险降低17.1%(95%CI 11.1%, 22.9%),NNT为6(95%CI 5, 9);撤管后预期Hb差异为5.0 g/L(95%CI 4.2, 5.8)。作者认为,VV-ECMO撤管期间使用BCS可能是提高血红蛋白水平并减少PRBC输注的有效策略。
要点
- 在841例VV-ECMO撤管患者中,BCS组撤管后2天内估计边际平均输注PRBC 0.2单位(95%CI 0.16, 0.25),n-BCS组0.51单位(95%CI 0.44, 0.59),平均处理效应-0.31单位(95%CI -0.40, -0.22)。
- BCS使接受任何PRBC输血的风险降低17.1%(95%CI 11.1%, 22.9%),NNT为6(95%CI 5, 9)。
- BCS与n-BCS撤管后预期Hb差异为5.0 g/L(95%CI 4.2, 5.8)。
- 作者认为,VV-ECMO撤管期间使用BCS可能是提高血红蛋白水平并减少PRBC输注的有效策略。
适用人群与场景
- 在英国两家ECMO中心接受VV-ECMO撤管的841例患者。
处置流程与药物剂量
- 在VV-ECMO撤管时使用血液细胞回收(BCS),与未行血液细胞回收(n-BCS)比较,评估撤管后2天内PRBC输注量及Hb变化。
研究设计与关键结果
- 研究类型:模拟试验分析,纳入英国两家ECMO中心841例接受VV-ECMO撤管的患者,采用逆倾向治疗加权控制混杂,比较BCS与n-BCS。
- 主要终点:BCS组撤管后2天内估计边际平均输注PRBC 0.2单位(95%CI 0.16, 0.25),n-BCS组0.51单位(95%CI 0.44, 0.59),平均处理效应-0.31单位(95%CI -0.40, -0.22)。
- BCS使接受任何PRBC输血的风险降低17.1%(95%CI 11.1%, 22.9%),NNT为6(95%CI 5, 9)。
- 撤管后预期Hb水平BCS与n-BCS差异为5.0 g/L(95%CI 4.2, 5.8)。
证据类型、等级与局限
- 证据类型:模拟试验分析(emulated trial analysis),采用逆倾向治疗加权控制混杂。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,VV-ECMO撤管期间使用BCS可能是提高血红蛋白水平并减少PRBC输注的有效策略。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Veno-venous extracorporeal membrane oxygenation (VV-ECMO) is a supportive therapy for acute respiratory failure with increased risk of packed red blood cells (PRBC) transfusion. Blood cell salvage (BCS) aims to reduce blood transfusion, but its efficacy is unclear. This study aimed to estimate the effect of BCS at the time of removal of the ECMO circuit (ECMO decannulation) on PRBC transfused.
METHODS: To compare BCS to non-blood cell salvage (n-BCS), we conducted an emulated trial of patients at two ECMO centres in the United Kingdom. We used inverse propensity of treatment weighting to control for confounding and estimated the average treatment effect of BCS on PRBC transfused within two days of decannulation, and on changes in haemoglobin (Hb).
RESULTS: We included 841 patients who underwent VV-ECMO decannulation. The estimated marginal mean number of PRBC transfused when using BCS was 0·2 (95%CI: 0·16, 0·25) units compared to 0·51 (95%CI: 0·44, 0·59) units with n-BCS; an average treatment effect of -0·31 (95%CI: -0·40, -0·22) units. BCS reduced the risk of receiving any PRBC transfusion by 17·1% (95%CI: 11·1%, 22·9%) equating to a number needed to treat for any PRBC transfusion of 6 (95%CI: 5, 9). The difference in expected Hb levels after decannulation between BCS and n-BCS was 5·0 (95%CI: 4·2, 5·8) g/L.
CONCLUSIONS: The use of BCS during VV-ECMO decannulation may be an effective strategy to augment haemoglobin levels and reduce PRBC transfusions.
参考来源
- Camarda V, Sanderson B, Barrett NA, et al. The effects of blood cell salvage on transfusion requirements after decannulation from veno-venous extracorporeal membrane oxygenation: an emulated trial analysis. Crit Care. 2024. PMID: 39639320. doi:10.1186/s13054-024-05177-7
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。