文献速递复苏、休克与脓毒症

德国院外心脏骤停中使用心肺复苏反馈设备:与自主循环恢复率改善相关但使用率低——基于107548例登记数据的分析

Use of CPR feedback devices to treat out-of-hospital cardiac arrest in Germany: Associated with improved ROSC-rates, but infrequent usage, in a registry-based analysis of 107,548 cases.
PubMed 文献 · Resuscitation · 2024-12-05
一句话结论德国院外心脏骤停中反馈设备使用率仅17.5%,校正后与任何自主循环恢复(ROSC)小幅相关(OR 1.09),但与入院时ROSC无关(OR 0.98)。

该研究基于德国复苏登记库2015至2022年107548例院外心脏骤停记录,回顾性比较使用与未使用实时视听反馈(RTAVF)设备患者的结局。反馈设备总体使用率为17.5%,从2015年7.1%升至2022年23.2%。使用反馈设备者入院时自主循环恢复率较未使用者高2.6%(35.9% vs 33.3%),两组ROSC率均高于RACA评分预测值。多因素校正后,RTAVF使用与任何ROSC有小幅关联(OR 1.09,95%CI 1.04-1.14),但与入院时ROSC无关联(OR 0.98,95%CI 0.93-1.03)。作者认为需进一步研究实施策略、可持续性及其他应用场景的有效性。

要点

  • 德国院外心脏骤停中反馈设备总体使用率仅17.5%,2015年7.1%升至2022年23.2%。
  • 使用反馈设备者入院时自主循环恢复率35.9%,未使用者33.3%,高2.6%。
  • 多因素校正后,反馈设备与任何ROSC小幅相关(OR 1.09,95%CI 1.04-1.14)。
  • 多因素校正后,反馈设备与入院时ROSC无关联(OR 0.98,95%CI 0.93-1.03)。
  • 两组ROSC率均高于RACA评分预测值。

适用人群与场景

  • 德国院外心脏骤停患者,由急救医疗服务人员救治,记录来自德国复苏登记库2015至2022年。

研究设计与关键结果

  • 研究类型:基于登记库的回顾性研究,分析德国复苏登记库2015至2022年107548例院外心脏骤停记录。
  • 干预与对照:比较使用与未使用实时视听反馈(RTAVF)设备患者的结局。
  • 反馈设备总体使用率17.5%,从2015年7.1%升至2022年23.2%。
  • 使用反馈设备者入院时自主循环恢复率35.9%,未使用者33.3%,高2.6%。
  • 两组ROSC率均高于RACA评分预测值。
  • 多因素校正后,RTAVF使用与任何ROSC相关(OR 1.09,95%CI 1.04-1.14)。
  • 多因素校正后,RTAVF使用与入院时ROSC无关联(OR 0.98,95%CI 0.93-1.03)。

证据类型、等级与局限

  • 证据类型:基于登记库的回顾性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,需进一步研究实施策略、可持续性并评估反馈设备在其他应用场景中的有效性。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Out-of-hospital cardiac arrest is a leading cause of mortality in Europe. Quality cardiopulmonary resuscitation, particularly of chest compressions, is crucial. Real-time audiovisual feedback (RTAVF) devices aim to enhance chest compression quality. Recent studies on these tools have reported improved outcomes for in-hospital but not for out-of-hospital cardiac arrest. This registry-based, retrospective study investigated the use of feedback-devices by emergency medical services personnel to treat out-of-hospital cardiac arrest in Germany and assessed its effect on return of spontaneous circulation (ROSC).

METHODS: We analyzed 107,548 records from the German Resuscitation Registry between 2015 and 2022 and compared patient outcomes of patients treated with feedback devices or not. ROSC rates both at any time and at hospital admission were compared to expected rates based on the "Rosc After Cardiac Arrest" (RACA) score. Furthermore, a generalized linear mixed methods model was calculated to receive an adjusted effect for those devices.

RESULTS: Feedback-devices were used in 17.5% of cases overall, rising from 7.1% (2015) to 23.2% (2022). Patients resuscitated with feedback devices had a 2.6% higher rate of hospital admission with spontaneous circulation (35.9% vs. 33.3%). In both groups, the ROSC rates were higher than predicted by the RACA score. After multivariable adjustment we found a minor effect for RTAVF use on any ROSC (odds ratio 1.09, 95% confidence interval 1.04-1.14), but no effect on the ROSC rate on admission (odds ratio 0.98, 95% confidence interval 0.93-1.03).

CONCLUSION: We could show a minor association between the use of feedback devices and any ROSC, but not for ROSC on hospital admission, in out-of-hospital cardiac arrest patients in a generalized linear mixed model. Further research should address implementation strategies, sustainability and evaluate its effectiveness for other applications.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Breuer-Kaiser AFC, Lefering R, Weber TP, et al. Use of CPR feedback devices to treat out-of-hospital cardiac arrest in Germany: Associated with improved ROSC-rates, but infrequent usage, in a registry-based analysis of 107,548 cases. Resuscitation. 2024. PMID: 39645022. doi:10.1016/j.resuscitation.2024.110453

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。