脓毒症的气味:电子鼻测量改善急诊早期识别脓毒症

The smell of sepsis: Electronic nose measurements improve early recognition of sepsis in the ED.
PubMed 文献 · Am J Emerg Med · 2024-11-26
一句话结论在急诊疑似感染患者中,床旁电子鼻测量诊断脓毒症的AUROC为0.78,验证模型AUC为0.83,可辅助早期识别。

本研究为队列研究,前瞻性收集急诊疑似感染患者的床旁电子鼻测量数据,基于Sepsis-3标准回顾性定义脓毒症。共分析160次电子鼻测量,判别分析显示诊断脓毒症的AUROC为0.78(95%CI 0.69-0.87),敏感性72%、特异性73%、总体准确率73%;验证模型AUC为0.83(95%CI 0.71-0.94),敏感性71%、特异性83%、准确率80%。结论认为电子鼻测量可在急诊疑似感染患者中识别脓毒症。

要点

  • 在急诊疑似感染患者中,床旁电子鼻测量诊断脓毒症的AUROC为0.78(95%CI 0.69-0.87),敏感性72%、特异性73%、准确率73%。
  • 验证子集模型显示AUC为0.83(95%CI 0.71-0.94),敏感性71%、特异性83%、准确率80%。
  • 脓毒症诊断基于Sepsis-3标准回顾性定义,电子鼻数据用于判别分析评估早期识别性能。
  • 数据集随机分为训练集(67%)和验证集(33%),判别函数来自训练集并应用于验证集分类。
  • 作者结论认为电子鼻测量可在急诊疑似感染患者中识别脓毒症。

适用人群与场景

  • 急诊科疑似感染的患者。

诊断标准与关键阈值

  • 脓毒症诊断基于Sepsis-3标准回顾性定义。

研究设计与关键结果

  • 研究类型为队列研究,前瞻性收集急诊疑似感染患者的床旁电子鼻测量数据,脓毒症诊断基于Sepsis-3标准回顾性定义;共分析160次电子鼻测量。
  • 电子鼻测量诊断脓毒症的AUROC为0.78(95%CI 0.69-0.87),敏感性72%,特异性73%,总体准确率73%。
  • 验证模型AUC为0.83(95%CI 0.71-0.94),敏感性71%,特异性83%,准确率80%。
  • 数据集随机分为训练集(67%)和验证集(33%),判别函数来自训练集并应用于验证集分类新观测。

证据类型、等级与局限

  • 证据类型:队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为电子鼻测量可在急诊疑似感染患者中识别脓毒症,可能有助于早期识别。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: Early recognition of sepsis is essential for timely initiation of adequate care. However, this is challenging as signs and symptoms may be absent or nonspecific. The cascade of events leading to organ failure in sepsis is characterized by immune-metabolic alterations. Volatile organic compounds (VOCs) are metabolic byproducts released in expired air. We hypothesize that measuring the VOC profile using electronic nose technology (eNose) could improve early recognition of sepsis.

MATERIAL AND METHODS: In this cohort study, bedside eNose measurements were collected prospectively from ED patients with suspected infections. Sepsis diagnosis was retrospectively defined based on Sepsis-3 criteria. eNose sensor data were used in a discriminant analysis to evaluate the predictive performance for early sepsis recognition. The dataset was randomly split into training (67 %) and validation (33 %) subsets. The derived discriminant function from the training subset was then applied to classify new observations in the validation subset. Model performance was evaluated using receiver operating characteristic (ROC) curves and predictive values.

RESULTS: We analyzed a total of 160 eNose measurements. The eNose measurements had an area under the ROC (AUROC) of 0.78 (95 % CI: 0.69-0.87) for diagnosing sepsis, with a sensitivity of 72 %, specificity of 73 %, and an overall accuracy of 73 %. The validation model showed an AUC of 0.83 (95 % CI: 0.71-0.94), sensitivity of 71 %, specificity of 83 %, and an accuracy of 80 %.

CONCLUSION: eNose measurements can identify sepsis among patients with a suspected infection at the ED.

CLINICAL TRIAL REGISTRATION: The study is embedded in the Acutelines data-biobank (www.acutelines.nl), registered in Clinicaltrials.gov (NCT04615065).

来源:Am J Emerg Med,查看原文。版权归原作者所有。