文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

急性呼吸窘迫综合征严重程度的病理生理标志物与电阻抗断层成像测得的通气/灌注失匹配相关

Pathophysiological Markers of Acute Respiratory Distress Syndrome Severity Are Correlated With Ventilation-Perfusion Mismatch Measured by Electrical Impedance Tomography.
PubMed 文献 · Crit Care Med · 2024-10-24
一句话结论在深度镇静、控制通气的ARDS成人患者中,EIT测得的失匹配通气/灌注单元与肺上皮/内皮功能障碍标志物、平台压及影像受累范围相关,可能反映ARDS严重程度。

本研究为前瞻性观察性研究,纳入大学附属医院综合ICU的25例深度镇静、气管插管、接受控制机械通气的成人ARDS患者,用电阻抗断层成像(EIT)测定失匹配通气/灌注单元(中位数37.1%,29.2-49.2%)。失匹配通气/灌注单元与血浆CA9(rho=0.47;p=0.01)、HIF1(rho=0.40;p=0.05)、RAGE(rho=0.46;p=0.02)、ANG2(rho=0.42;p=0.03)相关,与平台压(r=0.38;p=0.05)及胸片受累象限数(r=0.73;p<0.01)相关。区域失匹配通气/灌注单元与CT所示通气不良肺组织比例(r=0.62;p=0.01)及肺组织重量比例(rho=0.51;p=0.04)相关。作者认为失匹配通气/灌注单元可能代表ARDS严重程度的综合标志物。

要点

  • 25例深度镇静、控制通气的成人ARDS患者,EIT测得失匹配通气/灌注单元中位数为37.1%(29.2-49.2%)。
  • 失匹配通气/灌注单元与血浆CA9(rho=0.47;p=0.01)、RAGE(rho=0.46;p=0.02)、ANG2(rho=0.42;p=0.03)、HIF1(rho=0.40;p=0.05)相关。
  • 失匹配通气/灌注单元与平台压(r=0.38;p=0.05)及胸片受累象限数(r=0.73;p<0.01)相关。
  • 区域失匹配通气/灌注单元与CT所示通气不良肺组织比例(r=0.62;p=0.01)及肺组织重量比例(rho=0.51;p=0.04)相关。
  • 作者认为失匹配通气/灌注单元可能代表ARDS严重程度的综合标志物,反映复杂的器官病理生理并强化其预后意义。

适用人群与场景

  • 大学附属医院综合ICU中深度镇静、气管插管、接受控制机械通气的成人ARDS患者。

研究设计与关键结果

  • 前瞻性观察性研究,纳入25例深度镇静、气管插管、控制通气的成人ARDS患者,同时用EIT测定失匹配通气/灌注单元、测定血浆生物标志物、呼吸力学、气体交换及定量胸部CT。
  • 失匹配通气/灌注单元定义为通气但无灌注的肺单元加灌注但无通气的肺单元的分数,中位数为37.1%(29.2-49.2%)。
  • 失匹配通气/灌注单元与血浆CA9(rho=0.47;p=0.01)、HIF1(rho=0.40;p=0.05)、RAGE(rho=0.46;p=0.02)、ANG2(rho=0.42;p=0.03)相关。
  • 失匹配通气/灌注单元与平台压(r=0.38;p=0.05)及胸片受累象限数(r=0.73;p<0.01)相关。
  • 区域失匹配通气/灌注单元与CT所示通气不良肺组织比例(r=0.62;p=0.01)及肺组织重量比例(rho=0.51;p=0.04)相关。

证据类型、等级与局限

  • 证据类型:前瞻性观察性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在深度镇静、控制通气的成人ARDS患者中,EIT测得的失匹配通气/灌注单元与肺上皮及内皮功能障碍标志物、肺应力增加和肺水肿的病理生理标志物相关,作者认为其可能代表ARDS严重程度的综合标志物并强化其预后意义。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: Pulmonary ventilation/perfusion (V/Q) mismatch measured by electrical impedance tomography (EIT) is associated with the outcome of patients with the acute respiratory distress syndrome (ARDS), but the underlying pathophysiological mechanisms have not been fully elucidated. The present study aimed to verify the correlation between relevant pathophysiological markers of ARDS severity and V/Q mismatch.

DESIGN: Prospective observational study.

SETTING: General ICU of a university-affiliated hospital.

PATIENTS: Deeply sedated intubated adult patients with ARDS under controlled mechanical ventilation.

INTERVENTIONS: Measures of V/Q mismatch by EIT, respiratory mechanics, gas exchange, lung imaging, and plasma biomarkers.

MEASUREMENTS AND MAIN RESULTS: Unmatched V/Q units were assessed by EIT as the fraction of ventilated nonperfused plus perfused nonventilated lung units. At the same time, plasma biomarkers with proven prognostic and mechanistic significance for ARDS (carbonic anhydrase 9 [CA9], hypoxia-inducible factor 1 [HIF1], receptor for advanced glycation endproducts [RAGE], angiopoietin 2 [ANG2], gas exchange, respiratory mechanics, and quantitative chest CT scans were measured. Twenty-five intubated ARDS patients were included with median unmatched V/Q units of 37.1% (29.2-49.2%). Unmatched V/Q units were correlated with plasma levels of CA9 (rho = 0.47; p = 0.01), HIF1 (rho = 0.40; p = 0.05), RAGE (rho = 0.46; p = 0.02), and ANG2 (rho = 0.42; p = 0.03). Additionally, unmatched V/Q units correlated with plateau pressure ( r = 0.38; p = 0.05) and with the number of quadrants involved on chest radiograph ( r = 0.73; p < 0.01). Regional unmatched V/Q units were correlated with the corresponding fraction of poorly aerated lung tissue ( r = 0.62; p = 0.01) and of lung tissue weight (rho: 0.51; p = 0.04) measured by CT scan.

CONCLUSIONS: In ARDS patients, unmatched V/Q units are correlated with pathophysiological markers of lung epithelial and endothelial dysfunction, increased lung stress, and lung edema. Unmatched V/Q units could represent a comprehensive marker of ARDS severity, reflecting the complex organ pathophysiology and reinforcing their prognostic significance.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Spinelli E, Perez J, Chiavieri V, et al. Pathophysiological Markers of Acute Respiratory Distress Syndrome Severity Are Correlated With Ventilation-Perfusion Mismatch Measured by Electrical Impedance Tomography. Crit Care Med. 2024. PMID: 39445936. doi:10.1097/CCM.0000000000006458

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。