文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

急性低氧性呼吸衰竭中不对称气道闭合导致两肺充气延迟

Inter-lung asymmetrical airway closure cause insufflation delay between lungs in acute hypoxemic respiratory failure.
PubMed 文献 · Ann Intensive Care · 2024-10-23
一句话结论急性低氧性呼吸衰竭伴不对称气道闭合时,电阻抗断层成像可测两肺充气延迟,滴定PEEP可减少延迟。

研究纳入23例急性低氧性呼吸衰竭伴气道闭合患者(22例ARDS),用低流量压力-容积曲线和电阻抗断层成像(EIT)测量两肺气道开放压(AOP)及充气延迟。9例存在不对称气道闭合,病侧肺AOP为10 [6-13] cmH2O,健侧肺为5 [3-9] cmH2O。低流量充气时,无不对称与有不对称患者的肺间充气延迟分别为0 [0-112] ms与1450 [375-2400] ms,p<0.0001,延迟与两肺AOP差值相关(Spearman R2=0.800,p<0.0001)。将PEEP设定在EIT递减PEEP试验的交叉点可减少延迟;压力支持通气下延迟仍可测量,将PEEP从5增至10 cmH2O可减少延迟。

要点

  • 23例急性低氧性呼吸衰竭伴气道闭合患者中9例存在不对称气道闭合,病侧肺AOP 10 [6-13] cmH2O vs 健侧肺5 [3-9] cmH2O。
  • 低流量充气时肺间充气延迟:无不对称者0 [0-112] ms vs 有不对称者1450 [375-2400] ms,p<0.0001。
  • 潮式通气时肺间充气延迟:无不对称者0 [0-62] ms vs 有不对称者150 [50-355] ms,p=0.019。
  • 充气延迟与两肺AOP差值相关,Spearman R2=0.800,p<0.0001。
  • 将PEEP设定在EIT递减PEEP试验的交叉点可减少肺间充气延迟;压力支持通气下将PEEP从5增至10 cmH2O也可减少延迟。

适用人群与场景

  • 急性低氧性呼吸衰竭伴气道闭合的患者,23例中22例为ARDS。

诊断标准与关键阈值

  • 以EIT测量两肺气道开放压(AOP),不对称气道闭合定义为两肺AOP存在差异;病侧肺AOP为10 [6-13] cmH2O,健侧肺为5 [3-9] cmH2O。

处置流程与药物剂量

  • 在控制通气下记录低流量压力-容积曲线和EIT信号以测量两肺AOP和肺间充气延迟。
  • 将PEEP设定在递减EIT-based PEEP试验的交叉点,可减少肺间充气延迟。
  • 压力支持通气下,对不对称肺损伤患者将PEEP从5 cmH2O增至10 cmH2O可减少充气延迟。

研究设计与关键结果

  • 研究纳入23例急性低氧性呼吸衰竭伴气道闭合患者,其中22例ARDS;9例存在不对称气道闭合,病侧肺AOP为10 [6-13] cmH2O,健侧肺为5 [3-9] cmH2O。
  • 低流量充气时,无不对称与有不对称患者的肺间充气延迟分别为0 [0-112] ms与1450 [375-2400] ms,p<0.0001。
  • 充气延迟与两肺AOP差值相关,Spearman R2=0.800,p<0.0001。
  • 潮式通气时,无不对称与有不对称患者的肺间充气延迟分别为0 [0-62] ms与150 [50-355] ms,p=0.019。
  • 将PEEP设定在递减EIT-based PEEP试验的交叉点可减少肺间充气延迟。
  • 压力支持通气下充气延迟仍可测量,对不对称肺损伤患者将PEEP从5 cmH2O增至10 cmH2O可减少延迟。

证据类型、等级与局限

  • 证据类型:研究论文(摘要)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 对急性低氧性呼吸衰竭伴气道闭合患者,可用EIT监测两肺AOP和充气延迟,以识别不对称气道闭合。
  • 作者认为,在不对称气道闭合时,滴定PEEP可最小化肺间充气延迟,并可通过EIT监测。
  • 作者认为,在无法进行低流量充气曲线时,压力支持通气下减少延迟和通气不对称也是可行的。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Electrical Impedance Tomography (EIT) can quantify ventilation in the two lungs and be used to measure the airway opening pressure (AOP) of each lung. Asymmetrical AOPs can cause inter-lung insufflation delay.

OBJECTIVES: To assess the relation between AOP asymmetry and inter-lung insufflation delay at different PEEP levels.

METHODS: Patients with acute hypoxemic respiratory failure and airway closure were included. Low-flow pressure-volume curves and EIT signal were recorded during controlled ventilation and for some patients in pressure support ventilation.

RESULTS: 23 patients were studied, 22 patients had ARDS, 9 patients had asymmetrical airway closure with an AOP of 10 [6-13] cmH20 in the sicker lung (AOPsicker) vs. 5 [3-9, ] cmH20 in the healthier lung. During a low flow inflation, the inter-lung inflation delay was 0 [0-112]ms vs. 1450 [375-2400]ms in patients without or with asymmetrical AOPs, p < 0.0001. This delay was correlated to the difference of AOP between the 2 lungs, Spearman R2 = 0.800, p < 0.0001. During tidal ventilation, median delay was 0 [0-62] ms vs. 150 [50-355] ms in patients without vs. with asymmetry, p = 0.019. Setting PEEP at the crossing point of a decremental EIT-based PEEP trial decreased the inter-lung insufflation delay. During pressure support insufflation delay could still be measured and was reduced by increasing PEEP from 5 to 10 cmH2O in patient with asymmetrical lung injury.

CONCLUSION: In asymmetrical airway closure, titrating PEEP can minimize inter-lung insufflation delay and can be monitored by EIT. Reducing the delay and reducing ventilation asymmetry is also feasible during pressure support ventilation when low flow inflation curves cannot be performed.

来源:Ann Intensive Care,查看原文。版权归原作者所有。

参考来源

  1. Rozé H, Bonnardel E, Gallo E, et al. Inter-lung asymmetrical airway closure cause insufflation delay between lungs in acute hypoxemic respiratory failure. Ann Intensive Care. 2024. PMID: 39441425. doi:10.1186/s13613-024-01379-y

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。