自动头高位与常规心肺复苏的呼气末二氧化碳水平比较:一项前后干预试验

Comparison of end tidal CO2 levels between automated head up and conventional cardiopulmonary resuscitation: A pre-post intervention trial.
PubMed 文献 · Resuscitation · 2024-10-02
一句话结论在目击性院外心脏骤停患者中,AHUP-CPR较常规CPR显著提高呼气末二氧化碳峰值(40.7 vs 30.3 mmHg),但自主循环恢复率与30天神经功能良好生存率无显著差异。

本研究为法国前瞻性单臂前后干预试验,2019年10月至2022年10月纳入122例目击性院外心脏骤停患者,前干预期59例接受人工常规CPR,后干预期63例接受AHUP-CPR(自动头/胸抬高+主动加压-减压CPR+阻抗阈值装置ITD-16),两个时期均由医生第二梯队响应车辆提供高级生命支持。主要终点为CPR期间呼气末二氧化碳峰值,AHUP-CPR组为40.7 mmHg(SD 17.8),常规CPR组为30.3 mmHg(SD 13.1),平均差10.6(95%CI 4.6至16.1,P<0.001),且该差异不随初始心律变化(交互作用P=0.99)。自主循环恢复率(32.2% vs 33.3%)、入院存活率(28.8% vs 30.2%)及30天神经功能良好生存率(13.6% vs 11.1%)两组间无显著差异。

要点

  • AHUP-CPR组CPR期间呼气末二氧化碳峰值40.7 mmHg(SD 17.8),常规CPR组30.3 mmHg(SD 13.1),平均差10.6(95%CI 4.6至16.1,P<0.001)。
  • 呼气末二氧化碳峰值差异不随首次记录心律变化(交互作用P=0.99)。
  • 自主循环恢复率AHUP-CPR组33.3%(21例) vs 常规CPR组32.2%(19例),无显著差异。
  • 30天神经功能良好生存率AHUP-CPR组11.1%(7例) vs 常规CPR组13.6%(8例),无显著差异。
  • 基线呼气末二氧化碳两组相当:常规CPR组20.1 mmHg(SD 16.3) vs AHUP-CPR组19.2 mmHg(SD 16.3)。

适用人群与场景

  • 法国目击性院外心脏骤停患者,2019年10月至2022年10月纳入,前干预期由消防员实施人工常规CPR,后干预期实施AHUP-CPR,两个时期均由医生第二梯队响应车辆提供高级生命支持。

研究设计与关键结果

  • 前瞻性单臂前后干预试验,纳入122例目击性院外心脏骤停患者,平均年龄67岁(SD 17),前干预期59例接受人工常规CPR,后干预期63例接受AHUP-CPR。
  • 主要终点CPR期间呼气末二氧化碳峰值:常规CPR组30.3 mmHg(SD 13.1) vs AHUP-CPR组40.7 mmHg(SD 17.8),平均差10.6(95%CI 4.6至16.1,P<0.001)。
  • 基线呼气末二氧化碳:常规CPR组20.1 mmHg(SD 16.3) vs AHUP-CPR组19.2 mmHg(SD 16.3)。
  • 呼气末二氧化碳峰值平均差按首次记录心律分层无交互作用(交互作用P=0.99)。
  • 自主循环恢复率:常规CPR组32.2%(19例) vs AHUP-CPR组33.3%(21例),无显著差异。
  • 入院存活率:常规CPR组28.8%(17例) vs AHUP-CPR组30.2%(19例),无显著差异。
  • 30天神经功能良好生存率:常规CPR组13.6%(8例) vs AHUP-CPR组11.1%(7例),无显著差异。

证据类型、等级与局限

  • 证据类型:前瞻性单臂前后干预试验(pre-post intervention trial)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者结论:AHUP-CPR期间呼气末二氧化碳值达到非心脏骤停的正常生理水平范围,且显著高于常规CPR,与初始心律无关;但自主循环恢复率、入院存活率及30天神经功能良好生存率两组无显著差异。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The combination of controlled automated head/thorax elevation, active compression-decompression (ACD) cardiopulmonary resuscitation (CPR), and an impedance threshold device (ITD-16), termed AHUP-CPR, lowers intracranial pressure and increases circulation and neurologically-sound survival in pigs versus conventional (C) CPR. This study examined whether AHUP-CPR increased end tidal (ET) CO2, a non-invasive marker of cardiac output and organ perfusion, compared with C-CPR in witnessed out-of-hospital cardiac arrest patients.

METHOD: We conducted a prospective, single-arm, pre-post intervention trial in France between October 2019 and October 2022.Firefighters treated patients enrolled during the pre-intervention period with manual C-CPR and with AHUP-CPR during the post-intervention period. Advanced life support was provided by a physician-staffed 2nd-tier response vehicle for the two study periods. The primary outcome was the peak ETCO2 value measured during CPR.

RESULTS: 122 patients with a mean age of 67 years (standard deviation [SD], 17) were enrolled (59 in the pre-intervention period and 63 in the post-intervention period). Based on an intention-to-treat analysis, mean baseline ETCO2 values were comparable between pre- (20.1 mmHg, SD,16.3) and post-(19.2 mmHg, SD, 16.3) intervention periods. Mean peak ETCO2 values during CPR were 30.3 mmHg (SD, 13.1) versus 40.7 mmHg (SD, 17.8) for the pre- and post-intervention study periods (mean difference, 10.6, 95% confidence interval, 4.6 to 16.1, P < 0.001). Mean differences in peak ETCO2 between study periods did not vary according to the first recorded cardiac rhythm (P for interaction = 0.99). The proportion of return of spontaneous circulation [19 (32.2%) vs. 21 (33.3%)], survival on hospital admission [17 (28.8%) vs. 19 (30.2%)], and 30-day survival with favorable neurological outcome [8 (13.6%) vs. 7 (11.1%)] did not differ between study periods.

CONCLUSION: ETCO2 values during AHUP-CPR reached the range of non-arrest normal physiological levels and were significantly higher than with C-CPR, regardless of the presenting cardiac rhythm.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Debaty G, Segond N, Duhem H, et al. Comparison of end tidal CO2 levels between automated head up and conventional cardiopulmonary resuscitation: A pre-post intervention trial. Resuscitation. 2024. PMID: 39366543. doi:10.1016/j.resuscitation.2024.110406

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。