一句话结论耐久性机械循环支持患者心脏骤停行胸外按压未报告装置脱位,11项研究226例中71例(31.4%)预后良好。

国际复苏联络委员会高级、基础与儿科生命支持工作组采用人群、情境与概念框架对文献进行范围综述。共纳入32篇关于耐久性机械循环支持患者需急性复苏的文献,多数为病例报告或小样本病例系列,其中11篇(34.4%)涉及接受胸外按压的患者。部分研究报道因连续流左心室辅助装置患者预期无脉及担心机械循环支持装置可能脱位而延迟胸外按压。3项观察性研究显示接受胸外按压者预后较未接受者差,但偏倚风险高。11项研究和2篇已发表科学摘要共226例耐久性机械循环支持期间心脏骤停并接受胸外按压的患者中,未报告装置脱位事件,71例(31.4%)预后良好。

要点

  • 11项研究和2篇科学摘要共226例耐久性机械循环支持期间心脏骤停接受胸外按压的患者中,未报告装置脱位,71例(31.4%)预后良好。
  • 3项观察性研究显示接受胸外按压的耐久性机械循环支持心脏骤停患者预后较未接受者差,但偏倚风险高。
  • 部分研究报道因连续流左心室辅助装置患者预期无脉及担心装置脱位而延迟胸外按压。
  • 32篇文献中多数为病例报告或小样本病例系列,11篇(34.4%)涉及胸外按压。

适用人群与场景

  • 接受耐久性机械循环支持且出现急性灌注受损或心脏骤停、需要急性复苏的患者,涵盖院内与院外场景。

红旗征与不能漏的情况

  • 连续流左心室辅助装置患者可能无脉,导致救援者延迟胸外按压。
  • 救援者因担心机械循环支持装置可能脱位而延迟胸外按压。

研究设计与关键结果

  • 国际复苏联络委员会高级、基础与儿科生命支持工作组采用人群、情境与概念框架进行范围综述,共纳入32篇文献。
  • 多数研究为病例报告或小样本病例系列,其中11篇(34.4%)涉及接受胸外按压的患者。
  • 3项观察性研究显示接受胸外按压的耐久性机械循环支持心脏骤停和急性灌注受损患者预后较未接受胸外按压者差,但偏倚风险高。
  • 11项研究和2篇已发表科学摘要共226例耐久性机械循环支持期间心脏骤停并接受胸外按压的患者中,未报告装置脱位事件,71例(31.4%)预后良好。

证据类型、等级与局限

  • 证据类型:范围综述;多数纳入研究为病例报告或小样本病例系列。
  • 3项观察性研究偏倚风险高。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 原文结论指出,缺乏证据指导耐久性机械循环支持患者急性灌注受损和心脏骤停的复苏;报告提示复苏延迟常源于救援者对胸外按压安全性的不确定;胸外按压后未记录到装置脱位,提示及时心肺复苏对这些患者的伤害风险可能很小。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: There is an increasing prevalence of durable mechanical circulatory supported patients in both the in-and-out of hospital communities. The scientific literature regarding the approach to patients supported by durable mechanical circulatory devices who suffer acutely impaired perfusion has not been well explored.

METHODS: The International Liaison Committee on Resuscitation Advanced, Basic, and Pediatric Life Support Task Forces conducted a scoping review of the literature using a population, context, and concept framework.

RESULTS: A total of 32 publications that included patients who were receiving durable mechanical circulatory support and required acute resuscitation were identified. Most of the identified studies were case reports or small case series. Of these, 11 (34.4%) included patients who received chest compressions. A number of studies reported upon delays in the application of chest compressions resulting from complexity due to the expected pulselessness in some patients with continuous flow left-ventricular assist devices as well as from concern regarding potential dislodgement of the mechanical circulatory support device. Three observational studies identified worse outcomes in durable mechanical circulatory support receiving patients with cardiac arrest and acutely impaired perfusion who received chest compressions as compared to those who did not, however those studies were at high risk of bias. Of 226 patients across 11 studies and two published scientific abstracts who sustained cardiac arrest while supported by durable MCS and underwent chest compressions, there were no reported instances of device dislodgement and 71 (31.4%) patients had favorable outcomes.

CONCLUSIONS: There is a scarcity of evidence to inform the resuscitation of patients with durable mechanical circulatory support (MCS) experiencing acute impairment in perfusion and cardiac arrest. Reports indicate that delays in resuscitation often stem from rescuers' uncertainty about the safety of administering chest compressions. Notably, no instances of device dislodgement have been documented following chest compressions, suggesting that the risk of harm from timely CPR in these patients is minimal.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Moskowitz A, Pocock H, Lagina A, et al. Resuscitation of patients with durable mechanical circulatory support with acutely altered perfusion or cardiac arrest: A scoping review. Resuscitation. 2024. PMID: 39245405. doi:10.1016/j.resuscitation.2024.110389

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。