文献速递心脑血管急症重症综合管理与镇静镇痛

脑室内出血患者弥散张量成像系列变化与脑室血清除速率

Serial Diffusion Tensor Imaging and Rate of Ventricular Blood Clearance in Patients with Intraventricular Hemorrhage.
PubMed 文献 · Neurocrit Care · 2024-07-31
一句话结论在脑出血伴脑室内出血患者中,同侧脑室FA和MD随时间变化,并与脑室血体积和NIHSS评分相关,可能作为脑室血状态标志物。

该研究对26例脑出血伴脑室内出血患者在发病第1、14、28、42天进行磁共振成像,测量血肿体积、脑室血体积及同侧脑室脑脊液弥散指标FA和MD,其中14例接受脑室外引流。结果显示血肿体积日清除率2.1%、脑室血体积日清除率1.3%;同侧脑室FA每日下降1.3%、MD每日升高1.5%(后验概率均>99%)。脑室血体积与NIHSS评分强相关(后验概率97-99%),MD变化与脑室血体积相关。作者认为vFA和vMD可能作为脑室血状态的生物标志物。

要点

  • 26例脑出血伴脑室内出血患者中,血肿体积日清除率为2.1%,脑室血体积日清除率为1.3%。
  • 同侧脑室FA每日下降1.3%、MD每日升高1.5%,后验概率均>99%。
  • 接受脑室外引流的14例患者vFA下降更快(1.5% vs. 1.1%/天)、vMD升高更快(1.8% vs. 1.5%/天)。
  • 脑室血体积每增加1.00 cm3,vMD降低5.2%(后验概率<99%);脑室血体积与NIHSS评分强相关(后验概率97-99%)。
  • 作者认为vFA和vMD可能作为脑室血状态的生物标志物。

适用人群与场景

  • 脑出血并扩展至脑室的脑室内出血患者,共26例;其中14例接受脑室外引流。
  • 在发病第1、14、28、42天进行磁共振成像。

研究设计与关键结果

  • 研究类型为影像学队列研究,纳入26例脑出血伴脑室内出血患者,在发病第1、14、28、42天行磁共振成像,测量血肿体积、脑室血体积及同侧脑室脑脊液FA和MD;14例接受脑室外引流;采用广义线性混合模型统计分析。
  • 第1天平均血肿体积为14.6 ± 16.7 cm3,平均NIHSS评分为16 ± 8。
  • 血肿体积日清除率为2.1%,脑室血体积日清除率为1.3%。
  • 同侧脑室FA每日下降1.3%(后验概率>99%),同侧脑室MD每日升高1.5%(后验概率>99%)。
  • 接受脑室外引流患者vFA下降1.5%/天 vs. 未接受脑室外引流患者1.1%/天;vMD升高1.8%/天 vs. 1.5%/天。
  • 脑室血体积每增加1.00 cm3,vMD降低5.2%(后验概率<99%);脑室血体积与NIHSS评分强相关(后验概率97-99%)。
  • 脑脊液引流量较大与vFA下降更大相关(后验概率83.4%);引流量较小与vMD升高更大相关(后验概率94.8%)。

证据类型、等级与局限

  • 证据类型:影像学队列研究(26例,其中14例接受脑室外引流)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为vFA和vMD可能作为脑室血状态的生物标志物。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: We developed a noninvasive biomarker to quantify the rate of ventricular blood clearance in patients with intracerebral hemorrhage and extension to the ventricles-intraventricular hemorrhage.

METHODS: We performed magnetic resonance imaging in 26 patients at 1, 14, 28, and 42 days of onset and measured their hematoma volume (HV), ventricular blood volume (VBV), and two diffusion metrics: fractional anisotropy (FA), and mean diffusivity (MD). The ipasilesional ventricular cerebral spinal fluid's FA and MD were associated with VBV and stroke severity scores (National Institute of Health Stroke Scale [NIHSS]). A subcohort of 14 patients were treated with external ventricular drain (EVD). A generalized linear mixed model was applied for statistical analysis.

RESULTS: At day 1, the average HVs and NIHSS scores were 14.6 ± 16.7 cm3 and 16 ± 8, respectively. A daily rate of 2.1% and 1.3% blood clearance/resolution were recorded in HV and VBV, respectively. Ipsilesional ventricular FA (vFA) and ventricular MD (vMD) were simultaneously decreased (vFA = 1.3% per day, posterior probability [PP] > 99%) and increased (vMD = 1.5% per day, PP > 99%), respectively. Patients with EVD exhibited a faster decline in vFA (1.5% vs. 1.1% per day) and an increase in vMD (1.8% vs. 1.5% per day) as compared with patients without EVD. Temporal change in vMD was associated with VBV; a 1.00-cm3 increase in VBV resulted in a 5.2% decrease in vMD (PP < 99%). VBV was strongly associated with NIHSS score (PP = 97-99%). A larger cerebral spinal fluid drained volume was associated with a greater decrease (PP = 83.4%) in vFA, whereas a smaller volume exhibited a greater increase (PP = 94.8%) in vMD.

CONCLUSIONS: In conclusion, vFA and vMD may serve as biomarkers for VBV status.

来源:Neurocrit Care,查看原文。版权归原作者所有。

参考来源

  1. Vyas V, Savitz SI, Boren SB, et al. Serial Diffusion Tensor Imaging and Rate of Ventricular Blood Clearance in Patients with Intraventricular Hemorrhage. Neurocrit Care. 2024. PMID: 39085503. doi:10.1007/s12028-024-02070-7

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。